Every 96-well plate we carry, listed by part number in one table: assay plates, PCR plates, tissue-culture-treated plates and deep well plates from Caplugs® Evergreen, Globe Scientific, Accuris, Benchmark Scientific and Whatman. Each row carries the maker's catalog... Read More
Every 96-well plate we carry, listed by part number in one table: assay plates, PCR plates, tissue-culture-treated plates and deep well plates from Caplugs® Evergreen, Globe Scientific, Accuris, Benchmark Scientific and Whatman. Each row carries the maker's catalog number, so a reorder starts from the number on the box.
Which 96-well plate fits the job
Assay and sample plates. Caplugs polystyrene plates are offered with flat 0.37 mL wells (290-8115-01F), round 0.32 mL wells (290-8117-01R), conical 0.30 mL wells (290-8116-01V) and chamfered 0.35 mL wells (290-8118-01C). Polypropylene versions (290-8350-03F, 290-8353-03R, 290-8355-03V) take solvents that polystyrene will not, and 290-8120-0AF is the acrylic flat-bottom plate. Globe microtest plates cover U, V and flat bottoms (120030, 120130, 120330).
Black and white plates. Black walls (290-8195-Z1F flat, 290-8196-Z1R round) keep fluorescence from bleeding between wells; white walls (290-8027-W1F, 290-8029-W1R) bounce luminescence back to the detector. The Whatman UNIPLATE 7701-3250 is a white 250 µL V-bottom plate.
Cell culture. Tissue-culture-treated, sterile plates with lids, in flat, round and conical wells (333-8000-01F, 333-8002-01R, 333-8001-01V), plus Globe Diamond SureGro plates in flat (TC-PLT-96) and round (TC-PLT-96-R) bottoms.
PCR and qPCR. 0.1 and 0.2 mL plates with no skirt, a half skirt (including ABI-style), or a full skirt for robotic handling. Caplugs 214-3496 plates come in natural, blue, green, amber, red and yellow, so runs can be told apart at a glance, and Globe sells a barcoded full-skirted plate (PCR-DS-FS-01-CBC) for labs that track plates in a LIMS.
Deep well plates. 0.5 and 1.0 mL tapered wells (290-8525-010, 290-8551-01N) and 2.0 mL chamfered wells (290-8556-03C) for sample storage and extraction prep, the Benchmark IPD1196-MP 2.0 mL square-well genomics plate, and the Accuris AP1096-DWP deep well and AP1096-ELP elution plates made for the IsoPure extraction system.
Polystyrene or polypropylene
Pick polystyrene when the plate goes into a reader or an incubator: it is optically clear and the surface takes tissue-culture treatment. Pick polypropylene (PP or PPC) when the plate sees heat cycling, freezing or organic solvents. Whether a plate is sterile is stated in its name.