Collection: Surgically Clean Air
Commercial-grade air purification, bought manufacturer-direct as an authorized Surgically Clean Air partner — factory warranty from the date it ships, and Surgically Clean Air engineering support on sizing and installation.
Size it on air volume, not floor area
Ceiling height matters as much as floor area — a 1,200 sq ft room with a 16 ft ceiling holds twice the air of the same room at 8 ft. We size on room volume against each unit’s manufacturer-rated airflow. You set the air-changes-per-hour target.
1Where will the unit go?
2How big is the floor area?type an exact figure, or pick one
3How high is the ceiling?this changes the answer as much as floor area does
4What happens in the space?
5Target air changes per hourpick a target to see what it means for your room
* For medical and dental settings we typically recommend 15–20 ACH, due to the higher potential concentration of viruses, bacteria, aerosols and other airborne contaminants in those spaces.
Answer the five steps above — including the ceiling height — and the sizing appears here.
Surgically Clean Air purifiers — portable, wall, ceiling and industrial
Five units covering 861 to 40,000 sq ft of manufacturer-rated coverage, from a portable tower to a plant-floor machine.
JADE® 2.0$849Free-standing · 448 CFM · up to 1,500 ft²5-stage · HEPA-Rx H13 · carbon · UV-C · ionSKU AP-SCA5100CB / AP-SCA5100CW
ONYXsca®$849Wall-mount · 240 CFM · up to 1,000 ft²5-stage · pre · carbon · H13 HEPA · PCO · UV-CSKU AP-SCA2000CB / AP-SCA2000CW
COBALT® 2×2$2,495Ceiling grid · 430 CFM · up to 861 ft²MERV 16 HEPA-RX · 99.97% @ 0.3 µm · 2 filtersSKU AP-SCA14022W120V
COBALT® 2×4$3,495Ceiling grid · 1,171 CFM · up to 2,152 ft²MERV 16 HEPA-RX · 99.97% @ 0.3 µm · 2 filtersSKU AP-SCA14024W120V
ATOMIKAIR®$19,995Industrial · 17,383 CFM · up to 40,000 ft²5 × washable MERV-13 · pre-filter · mist collector · carbonSKU AP-SCA9000 (480V / 600V)
Full model comparison
Manufacturer-published figures. Prices are Surgically Clean Air list.
| Model | Mounting | Airflow | Coverage | Sound dB(A) | Power | Filtration | MSRP |
|---|---|---|---|---|---|---|---|
| JADE® 2.0AP-SCA5100CB / AP-SCA5100CW | Free-standing | 448 CFM | up to 1,500 ft² | 37.3–58 | 19.2–63.6 W | 5-stage · HEPA-Rx H13 · carbon · UV-C · ion | $849 |
| ONYXsca®AP-SCA2000CB / AP-SCA2000CW | Wall-mount | 240 CFM | up to 1,000 ft² | <40–55 | Not published | 5-stage · pre · carbon · H13 HEPA · PCO · UV-C | $849 |
| COBALT® 2×2AP-SCA14022W120V | Ceiling grid | 430 CFM | up to 861 ft² | 22.5–47.5 | 70 W | MERV 16 HEPA-RX · 99.97% @ 0.3 µm · 2 filters | $2,495 |
| COBALT® 2×4AP-SCA14024W120V | Ceiling grid | 1,171 CFM | up to 2,152 ft² | 30.6–51.9 | 250 W | MERV 16 HEPA-RX · 99.97% @ 0.3 µm · 2 filters | $3,495 |
| ATOMIKAIR®AP-SCA9000 (480V / 600V) | Industrial | 17,383 CFM | up to 40,000 ft² | Not published | Not published | 5 × washable MERV-13 · pre-filter · mist collector · carbon | $19,995 |
The five-stage filtration path
Air passes through every stage in sequence on each pass. The JADE 2.0 stack is shown below; ONYXsca uses the same five-stage architecture.
Where these units get specified
The right unit is usually decided by the room, not the budget. Start from the space you are fitting out.
Dental & Medical OperatoriesWall-mount keeps the floor clear
Laboratories & CleanroomsPortable units follow the work
Classrooms & Lecture HallsCeiling grid, nothing reachable
Offices & Conference RoomsQuiet enough for a call
Factories & WarehousingSilica-ready, plant-scale airflow
Veterinary & Animal CareOdour control on the carbon stage
Food Processing & Cold StorageWashable filters, audit-ready
Retail & Grocery FloorsLong hours, constant door traffic
Salons, Spas & Med-SpasLow dB on the working speeds
How to size an air purifier for a commercial space
Work from air volume, not floor area
A purifier moves air by volume. Two rooms with the same floor plan but different ceilings do not hold the same amount of air, so they do not need the same airflow. The number that governs the specification is air changes per hour (ACH) — how many times the full volume of air in the room passes through filtration in an hour.
Required CFM = (length × width × ceiling height ÷ 60) × target ACHDimensions in feet. The result is the airflow the room needs, in cubic feet per minute. Your ACH target comes from your own specification or your engineer.
A worked example
A 1,200 sq ft room with a 9 ft ceiling holds 10,800 ft³ of air. At a target of 5 ACH it needs (10,800 ÷ 60) × 5 = 900 CFM. One COBALT 2×4 delivers 1,171 CFM and covers it. Raise the ceiling to 16 ft and the same floor plan holds 19,200 ft³, needs 1,600 CFM, and now takes two units.
What Surgically Clean Air publishes
Manufacturer-rated airflow and coverage for each unit:
- JADE 2.0 — 135 to 448 CFM, up to 1,500 sq ft. The manufacturer states that coverage figure as up to 2.5 air changes per hour.
- ONYXsca — 125 / 195 / 240 CFM across three speeds, up to 1,000 sq ft.
- COBALT 2×2 — 430 CFM, up to 861 sq ft, replacing one 24 × 24 in ceiling tile.
- COBALT 2×4 — 1,171 CFM, up to 2,152 sq ft, replacing one 24 × 48 in ceiling tile.
- ATOMIKAIR — 17,383 CFM, up to 40,000 sq ft, scoped per facility by the manufacturer.
Where a published coverage figure and your own ACH target disagree, size on airflow. That is what the selector above does.
Recommended air changes for medical and dental spaces
For medical and dental settings we typically recommend 15–20 ACH, due to the higher potential concentration of viruses, bacteria, aerosols and other airborne contaminants in those spaces. That is several times the 4–6 range a general office or classroom is usually specified at, and it changes the unit count substantially — a 1,200 sq ft operatory with a 9 ft ceiling needs 900 CFM at 5 ACH but 2,700 CFM at 15 ACH. Select Dental / medical in the selector above and it sets that target for you.
Filtration, as the manufacturer states it
- COBALT — MERV 16 HEPA-RX, rated 99.97% at 0.3 microns, two filters per unit, with an optional HEPA carbon hybrid for odour and VOC control.
- JADE 2.0 — five stages: pre-filter, HEPA-Rx, activated carbon, UV-C lamp and a negative ion chamber. Rated CADR 344.5 CFM and BioCADR 420 CFM.
- ONYXsca — five stages including activated carbon, H13 HEPA and UV-C, with VOC, PM2.5 and humidity sensors.
- ATOMIKAIR — five washable MERV-13 filters plus a semi-permanent pre-filter, mist collector and activated carbon. Nothing in the train is disposable.
Sound matters more than buyers expect
A unit that gets switched off is filtering nothing. Check the dB(A) figure at the speed you will actually run, not at minimum. Surgically Clean Air publishes 22.5 to 47.5 dB(A) for the COBALT 2×2, 30.6 to 51.9 dB(A) for the COBALT 2×4, 37.3 to 58 dB for the JADE 2.0, and 40 / 47 / 55 dB across the ONYXsca's three speeds.
Authorized partner, not a reseller
Manufacturer-direct
We buy from Surgically Clean Air, so units are current revision and the factory warranty is valid from the day it ships.
SCA engineering on the call
Sizing, ceiling-grid loading and 3-phase questions go to SCA's product team, not to a call centre script.
Registered at purchase
We register your serial number with SCA at point of sale, so warranty and filter scheduling are on file from the start.
Consumables handled
Filters, UV lamps and replacement parts come direct from the manufacturer for the life of the unit.
Surgically Clean Air — common questions
What size air purifier do I need for my room?
Work from the volume of air in the room, not the floor area alone. Required airflow in CFM = (room length × width × ceiling height ÷ 60) × your target air changes per hour (ACH). Match that against each unit's manufacturer-rated airflow — JADE 2.0 delivers 135 to 448 CFM, ONYXsca 125 / 195 / 240 CFM, COBALT 2×2 430 CFM, COBALT 2×4 1,171 CFM, and ATOMIKAIR 17,383 CFM. The selector above does the arithmetic. Your ACH target is set by your own specification or your engineer, not by us.
What air changes per hour should a medical or dental space use?
For medical and dental settings we typically recommend 15–20 ACH, due to the higher potential concentration of viruses, bacteria, aerosols and other airborne contaminants in those spaces. That is several times the 4–6 range a general office or classroom is usually specified at. A 1,200 sq ft operatory with a 9 ft ceiling needs 900 CFM at 5 ACH but 2,700 CFM at 15 ACH, so the unit count changes substantially. Selecting Dental / medical in the selector sets that target for you.
How long does one air change take?
Divide 60 by your target. At 5 ACH the full volume of air in the room passes through filtration once every 12 minutes; at 8 ACH every 7 minutes 30 seconds; at 15 ACH every 4 minutes; at 20 ACH every 3 minutes. The selector shows this for whichever target you pick, along with the airflow your room needs to achieve it.
Why does ceiling height change the answer?
Because a purifier moves air by volume, not by floor plan. A 1,200 sq ft room with a 16 ft ceiling holds twice the air of the same room at 8 ft, so it needs twice the airflow to reach the same air changes per hour. A single square-footage rating cannot describe both rooms, which is why the selector asks for the height.
What coverage does Surgically Clean Air publish for each unit?
JADE 2.0 up to 1,500 sq ft, ONYXsca up to 1,000 sq ft, COBALT 2×2 up to 861 sq ft, COBALT 2×4 up to 2,152 sq ft, and ATOMIKAIR up to 40,000 sq ft. On the JADE 2.0 the manufacturer states that 1,500 sq ft figure as up to 2.5 air changes per hour. If your target is higher than that, or your ceiling is higher than the figure assumes, size on airflow instead.
What do the COBALT and JADE filters capture?
Surgically Clean Air rates the COBALT's MERV 16 HEPA-RX medium at 99.97% at 0.3 microns, and publishes 99.97% at 0.3 microns for the JADE 2.0 as well. The JADE 2.0 specification sheet in our file also states an H13-grade HEPA-Rx filter at 99.95% efficiency at MPPS, the manufacturer's own term. Ask us for the current filter datasheet on any model before you specify it.
Can the COBALT go into an existing drop ceiling?
Yes. The 2×2 replaces one 24 × 24 in tile and the 2×4 replaces one 24 × 48 in tile in a standard suspended T-bar grid. The manufacturer lists them at 44 lbs and 96 lbs respectively, so the grid and any seismic bracing must be rated for the load — have your contractor confirm before ordering.
How is the ATOMIKAIR specified?
Surgically Clean Air sizes the ATOMIKAIR per facility rather than selling it from a shelf. It moves 17,383 CFM, treats up to 40,000 sq ft, runs on 240V, 480V or 600V, and uses five washable MERV-13 filters with a pre-filter, mist collector and activated carbon — no disposable filters at all. It is OSHA 29 CFR 1926.1153 silica-ready and used in AIB, USDA, CFIA and GMP audit environments. Send us square footage, ceiling height, processes and voltage and we will have it scoped.
Where do I get replacement filters and UV lamps?
Directly from Surgically Clean Air. As an authorized partner we register your unit at the point of sale, and Surgically Clean Air handles consumables, warranty service and technical support for the life of the equipment — one accountable line, with no third party in the middle. Register your serial number at purchase so your warranty and filter schedule are on file.
What is the warranty?
One year limited, beginning when the unit ships from Surgically Clean Air. On the JADE 2.0 the manufacturer extends it to five years when replacement filters are purchased annually. Full terms are at surgicallycleanair.com/warranty-service.
Why buy from LabSupplies.com instead of anywhere else?
We are an authorized Surgically Clean Air partner buying from the manufacturer, not from a reseller. That means the factory warranty is valid from the day the unit ships, and sizing and installation questions go to Surgically Clean Air's own engineers rather than to a call centre.
Search the range, or have us size it for you
Send the room dimensions and ceiling height and we will come back with the unit count and a freight quote.
Browse every Surgically Clean Air unit below
Surgically Clean Air®, JADE®, ONYXsca®, COBALT® and ATOMIKAIR® are registered trademarks of Surgically Clean Air LLC. LabSupplies.com is an authorized partner. Specifications and pricing are the manufacturer's published figures and are subject to change. Prices shown are list and exclude freight; heavy and freight-class units are quoted at time of order.
-
Surgically Clean Air JADE 2.0 Portable Air Purifier, 448 CFM, HEPA H13 + UV-C, 120V — SCA5100C
Vendor:Surgically Clean AirRegular price $849.00Regular priceUnit price / perSale price $849.00 -
Surgically Clean Air ONYXsca Wall-Mount Air Purifier, 240 CFM, 5-Stage HEPA-Rx + UV-C — SCA2000C
Vendor:Surgically Clean AirRegular price $849.00Regular priceUnit price / perSale price $849.00 -
Surgically Clean Air COBALT 2x2 Ceiling Air Purifier, 430 CFM, MERV 16 HEPA-RX, 120V — AP-SCA14022W120V
Vendor:Surgically Clean AirRegular price $2,495.00Regular priceUnit price / perSale price $2,495.00 -
Surgically Clean Air COBALT 2x4 Ceiling Air Purifier, 1,171 CFM, MERV 16 HEPA-RX, 120V — AP-SCA14024W120V
Vendor:Surgically Clean AirRegular price $3,495.00Regular priceUnit price / perSale price $3,495.00 -
Surgically Clean Air ATOMIKAIR Industrial Air Purifier, 17,383 CFM, Washable MERV-13 — 40,000 sq ft
Vendor:Surgically Clean AirRegular price $19,995.00Regular priceUnit price / perSale price $19,995.00