Skip to product information
1 of 1

Yamato Scientific

Yamato SM820 Large Capacity Sterilizer With Dryer 80L

Yamato SM820 Large Capacity Sterilizer With Dryer 80L

Regular price $20,915.00
Regular price Sale price $20,915.00
Sale Sold out
Shipping calculated at checkout.
Voltage
View full product details

In stock (US) — ships in 2–5 business daysSM-820 · Yamato Scientific America US stock report

In stock (US) — ships in 2–5 business daysSM-830 · Yamato Scientific America US stock report

Why order the SM820 from LabSupplies.com

Authorized Yamato Scientific dealerGenuine new Yamato equipment and parts, listed by Yamato part number.
1-year Yamato warrantyYamato Scientific America's published warranty, from shipment. Valid only through authorized dealers.
Ships from US inventoryStock status above comes straight from Yamato's US stock report.
Yamato-certified serviceCalibration and preventive maintenance on site or at Yamato's California service center.
Chamber80 L
Drying150–180°C
Exterior (W × D × H)520 × 660 × 1161 mm
Power115V / 220V

Large Capacity Sterilizer With Dryer 80L Overview

The Large Capacity Sterilizer With Dryer 80L (Yamato Scientific SM820) is a fully automatic steam autoclave delivering an 80 L chamber with a sterilizing temperature range of 105 to 135°C and an integrated drying stage of 135 to 150°C. LabSupplies.com supplies this unit as an authorized Yamato Scientific dealer.

Key Features

  • Fully automatic cycle: high-pressure steam sterilization through drying runs start to finish without operator intervention.
  • 7-inch touch control: interactive touch panel sets and stores sterilization time and temperature in memory.
  • Wide temperature range: sterilizes 105 to 135°C and dries 135 to 150°C, with a 135°C maximum operating temperature suited to protein modification.
  • Layered safety: multiple lid-locking mechanisms, forced cooling, and a buzzer alarm on high or low pressure errors.
  • Voltage options: order SM820 for 100-120V service or SM830 for 200-240V service.

How to Choose the Right Sterilizer / Autoclave

  • Voltage: confirm whether your bench circuit is 100-120V (SM820) or 200-240V (SM830) before purchase.
  • Footprint and weight: Yamato lists external dimensions (W × D × H) of 520 × 660 × 1161 mm (20.5 × 26.0 × 45.7 in); packed for shipping it measures 25 × 33 × 55 in at 405 lb.

Specifications

Specification Detail
Capacity 80 L
Voltage 115V
System Automatic high-pressure steam sterilizer with dryer
Temperature Control System PID control by microprocessor
Interior Material Stainless steel
Country of Origin China
GTIN (Barcode) 797059927333
Shipping Weight 405 lbs
External Dimensions (W × D × H) 520 × 660 × 1161 mm (20.5 × 26.0 × 45.7 in)
Shipping Dimensions (L × W × H) 25 × 33 × 55 in
Component Size 80 L
Warranty 1 year (Yamato Scientific America)
Service Calibration and preventive maintenance on site by Yamato-certified technicians or at Yamato's California service center

Compare SM Series Models

Model Capacity Temperature range Exterior Shipping weight
SM201 20 L 105 to 123°C (sterilization) 410 × 470 × 957 mm (16.1 × 18.5 × 37.7 in) 216 lbs
SM301 32 L 105 to 128°C (sterilization) 440 × 530 × 968 mm (17.3 × 20.9 × 38.1 in) 250 lbs
SM501 47 L 105 to 128°C (sterilization) 440 × 530 × 1088 mm (17.3 × 20.9 × 42.8 in) 271 lbs
SM520 50 L — 520 × 660 × 881 mm (20.5 × 26.0 × 34.7 in) 342 lbs
SM820 (this model) 80 L — 520 × 660 × 1161 mm (20.5 × 26.0 × 45.7 in) 405 lbs

Ordering Information

Catalog number Configuration GTIN / UPC
SM-820 115V 797059927333
SM-830 220V 797059927340
Manufacturer Yamato Scientific
Manufacturer part numbers SM-820, SM-830
UNSPSC 42281508 — Autoclaves or steam sterilizers
HTS code 8419.20.0020
Export classification (ECCN) EAR99

Documents & Downloads

Parts & Accessories for the SM820

Genuine Yamato SM-series parts. Fitment is taken from each part's Yamato description.

More in This Series

View all Laboratory Autoclaves & Sterilizers →

Frequently Asked Questions

What is the temperature range of the SM820 sterilizer?

The sterilizing range is 105 to 135°C, with a separate drying stage of 135 to 150°C. The 135°C maximum operating temperature also supports protein modification work.

What is the chamber capacity and footprint?

Yamato lists external dimensions (W × D × H) of 520 × 660 × 1161 mm (20.5 × 26.0 × 45.7 in); packed for shipping it measures 25 × 33 × 55 in at 405 lb. It also includes a heat-resistant 11 L stainless steel container for bulk loads.

What is the difference between the SM820 and SM830?

Voltage is the only difference. SM820 operates on 100-120V and SM830 operates on 200-240V; both share the same 80 L chamber, temperature ranges, and feature set.

How does the operator control sterilization cycles?

A 7-inch interactive touch panel sets sterilization time and temperature and commits those settings to memory. Forced cooling, memory functions, and a pressure-error buzzer support automatic operation.

Which replacement parts and accessories are listed for the Yamato SM820?

Yamato lists 17 parts for the SM Series: 241083, 241084, 241087, 241088, 241089, 241090 and 11 more. Each is linked with its description in the parts table on this page.

What is the UNSPSC code for the Yamato SM820?

The Yamato SM820 is classified under UNSPSC 42281508 (autoclaves or steam sterilizers).

Where is the Yamato SM820 manufactured?

Yamato Scientific lists China as the country of origin for the SM820.

Is there a spec sheet or brochure for the Yamato SM820?

Yes. The Yamato SM Series Large-Capacity Sterilizer with Dryer brochure (1.4 MB PDF) is linked under Documents & Downloads on this page.

How does the Yamato SM820 compare with the other SM Series models?

Yamato builds this SM Series line in 5 sizes: 20 L (SM201), 32 L (SM301), 47 L (SM501), 50 L (SM520) and 80 L (SM820). The comparison table on this page lists capacity, temperature range, exterior and shipping weight side by side.