Large Capacity Sterilizer With Dryer 50L Overview

The Large Capacity Sterilizer With Dryer 50L (Yamato Scientific SM520) is a fully automatic steam autoclave in the Autoclaves category, delivering high-pressure steam sterilization and drying across a 50 L chamber. Sterilizing temperatures span 105 to 135°C, while the integrated drying cycle runs 135 to 150°C. A 7-inch interactive touch panel commits time and temperature settings to memory. LabSupplies.com supplies this unit as an authorized dealer.

Construction pairs a coated cold-rolled steel exterior with an SUS304 stainless steel chamber and cover for corrosion resistance under repeated steam cycles. Each unit ships with an 11 L heat-resistant stainless steel container. Multiple lid-locking mechanisms secure the cover during pressurized operation. An alarm buzzer signals high- or low-pressure faults, and forced cooling plus memory functions streamline repeat runs.

Two voltage configurations cover most lab installations: SM520 runs 100-120V and SM530 runs 200-240V. The unit measures 25 × 33 × 44 inches (L×W×H) and weighs 342 lbs, so verify bench or floor clearance before delivery. Manufacturing follows ISO 9001:2015 quality-management and ISO 14001:2015 environmental-management systems.

Key Features

  • 7-inch touch panel: interactive keypad input stores sterilization time and temperature settings to memory for repeatable cycles.
  • Sterilization and drying range: sterilizes 105 to 135°C and dries 135 to 150°C, suiting protein modification at the 135°C maximum operating temperature.
  • 50 L SUS304 chamber: stainless steel chamber and cover resist corrosion, supported by a coated cold-rolled steel exterior.
  • Included 11 L container: heat-resistant stainless steel container ships with the unit for loading flexibility.
  • Multi-point lid safety: multiple locking mechanisms secure the cover during pressurized operation.
  • Forced cooling and fault alarm: forced cooling and memory functions speed turnaround, while an alarm buzzer flags high- or low-pressure errors.

How to Choose the Right Sterilizer / Autoclave

Matching an autoclave to a lab means weighing throughput, process temperature, control style, and site power against your bench or floor space. Use the criteria below to confirm this 50 L unit fits your workflow before ordering.

  • Chamber capacity: a 50 L chamber handles larger loads and taller vessels; confirm your batch volume and the included 11 L container meet daily demand.
  • Temperature range: sterilizing 105 to 135°C with a 135 to 150°C drying step covers standard media, glassware, and protein-modification work at the 135°C ceiling.
  • Control type: the 7-inch touch panel with memory suits labs that repeat defined cycles and want stored programs over manual setup.
  • Voltage and site power: select SM520 for 100-120V circuits or SM530 for 200-240V to match available service.
  • Footprint and weight: verify clearance for the 25 × 33 × 44 inch envelope and 342 lb load before delivery.
  • Safety features: multiple lid locks, forced cooling, and a high/low-pressure alarm support unattended and repeat-cycle operation.

Specifications

Specification Detail
Capacity 50 L
Voltage 115V
System Automatic high-pressure steam sterilizer with dryer
Drying Temperature Range 150 to 180°C
Temperature Control System PID control by microprocessor
Interior Material Stainless steel
Safety Devices Self-diagnostic functions (sensor error, SSR short-circuit, heater disconnection, faulty main relay, dry-run detection); safety valve; electric leakage breaker; drain-bottle set-fail switch
Material Cold rolled steel plate with coating (exterior) Stainless steel SUS304 (chamber/cover)
Country of Origin China
GTIN (Barcode) 797059927319
Shipping Weight 342 lbs
Dimensions (L × W × H) 25 × 33 × 44 in
Component Size 50 L

Available Sizes and Configurations

SKU Configuration Pack
SM-520 115V EA
SM-530 220V EA

Documentation

More in This Series

Why Buy From LabSupplies.com

LabSupplies.com supplies the Yamato Scientific SM520 and SM530 as an authorized dealer, so every unit is genuine and backed by the manufacturer warranty. Order directly online and our lab-equipment specialists can confirm voltage, footprint, and configuration details before you commit.

  • Authorized Yamato Scientific dealer: genuine equipment with full manufacturer warranty coverage.
  • In stock: available now and ready to process from current inventory.
  • Ships from USA inventory: fulfilled domestically for predictable delivery.
  • Lab-equipment specialists: dedicated support for voltage, capacity, and spec questions.

Frequently Asked Questions

What is the temperature range of the SM520 sterilizer?

Sterilizing temperatures span 105 to 135°C, and the drying cycle runs 135 to 150°C. The 135°C maximum operating temperature also suits protein-modification applications.

What is the chamber capacity and overall size?

The chamber holds 50 L and the unit ships with an 11 L heat-resistant stainless steel container. Overall dimensions are 25 × 33 × 44 inches (L×W×H), with a unit weight of 342 lbs.

What is the difference between the SM520 and SM530?

Voltage is the only difference. SM520 operates on 100-120V (115V) and SM530 operates on 200-240V (220V); both share the same 50 L capacity, temperature ranges, and feature set.

What materials are used in the chamber and exterior?

The chamber and cover are SUS304 stainless steel for corrosion resistance. The exterior is coated cold-rolled steel plate.

What safety features does the autoclave include?

Multiple lid-locking mechanisms secure the cover during pressurized operation. An alarm buzzer sounds on high- or low-pressure errors, and forced cooling supports controlled cycle completion.

How are sterilization settings controlled?

A 7-inch interactive touch panel handles input. Time and temperature settings can be committed to memory for repeatable cycles across multiple sterilization processes.