Temporarily unavailable. Yamato Scientific America has temporarily suspended sales of the ULF and LTF freezer series to comply with EPA and CARB refrigerant requirements. Yamato is replacing them with the VUF and VLF series.
Why order the ULF201CP from LabSupplies.com
Platinum Chest Style Ultra Low Freezers -40°C To -85°C, 5 cu.ft., Manual Defrost Overview
The Platinum Chest Style Ultra Low Freezers -40°C To -85°C, 5 cu.ft., Manual Defrost (model ULF201CP) is a cascade-refrigeration laboratory freezer from Yamato Scientific. Sold by LabSupplies.com as an authorized dealer, this chest-style unit holds 142 L (5 cu.ft.) and reaches set points from -40°C to -85°C. A touch-screen controller manages temperature, alarms, and data logging.
Chamber walls use 14-gauge zinc-coated galvanized steel, while the exterior is 16-gauge steel finished in powder-coated cool gray. Two hermetic compressors form a cascade refrigeration system charged with CFC-free R-508B and HCFC-free R-404A. Air-cooled condensing with two heavy-duty fans removes heat, so no liquid coolant is required. Manual defrost keeps the design straightforward.
Power options cover 115V, 208V, and 230V at 60 Hz, plus 220V at 50/60 Hz, all single-phase. Exterior dimensions measure 40.5" × 31" × 47", and the unit weighs 525 lbs. Built in the USA, this freezer is UL Listed. Interior space accepts up to 15 racks for high-density sample storage.
Key Features
- Touch-screen control: displays set point and chamber temperature, with viewable temperature graph, multi-level security, and downloadable data logging.
- Cascade refrigeration: two hermetic compressors run CFC-free R-508B and HCFC-free R-404A, cooled by an air-cooled condenser with two heavy-duty fans.
- Alarm system: battery-operated audible and visual signals for mechanical or electrical failure, with over/under-temperature settings, silencing switch, and battery test switch.
- Remote connectivity: Hi/Low alarms with email and SMS notification, alarm-relay and power-failure dry contacts, plus VNC remote access via PC or smart devices.
- Power failure recovery: automatic timer system restarts the unit after a power failure.
How to Choose the Right Ultra-Low Freezer
Selecting an ultra-low freezer comes down to matching sample volume, temperature target, and site infrastructure to the unit you specify. Use the criteria below to align the freezer with your lab's workflow.
- Voltage: verify your facility power against the 115V, 208V, 230V (60 Hz) and 220V (50/60 Hz) single-phase options before installation.
- Footprint: chest-style cabinets like this 40.5" × 31" × 47" unit offer top-access storage where floor space allows a horizontal layout.
Specifications
| Specification | Detail |
|---|---|
| Capacity | 5 cu.ft. |
| Temperature Range | -40°C to -85°C |
| Defrost | Manual |
| Interior Capacity | 142 L / 5 cu.ft. |
| Rack Capacity | 15 racks |
| Interior Dimensions | 30" × 18" × 16" (76 × 45 × 40 cm) |
| Exterior Dimensions | 40.5" × 31" × 47" (102 × 81 × 119 cm) |
| Temperature Control System | Touch-screen control displaying set point and chamber temperature; Hi/Low alarm with email and SMS notification; alarm-relay and power-failure dry contacts; battery back-up; viewable temperature graph; data logging downloadable via USB or FTP; multi-level security; VNC remote access via PC or smart devices |
| Access Port | 1/2" porthole in the left-hand side of the cabinet, with plugs |
| Refrigeration System | Cascade type — two hermetic compressors |
| Refrigerant | CFC-free R-508B and R-404A (CFC- & HCFC-free) |
| Condenser | Air-cooled with two heavy-duty fans; no liquid coolant required |
| Alarm System | Battery-operated alarm emits an audible and visual signal on mechanical or electrical failure; over- and under-temperature settings, alarm silencing switch, and battery test switch; relay provided for remote alarm hook-up |
| Power Failure Recovery | Automatic timer system restarts the unit after a power failure |
| Electrical Requirements | 115V / 208V / 230V, 60 Hz, 1-phase; 220V, 50/60 Hz, 1-phase |
| Optional Accessories | CO₂ and LN₂ back-up system; racks; cold safety gloves |
| Material | Chamber is 14-ga. Zinc coated galvanized steel. Exterior is 16-ga. steel. Power coated cool gray |
| Country of Origin | USA |
| GTIN (Barcode) | 797059930425 |
| Shipping Weight | 525 lbs |
| Shipping Dimensions (L × W × H) | 46 × 41 × 55 in |
| Component Size | 5 CF |
| Other Certification | UL Listed |
| Warranty | 1 year (Yamato Scientific America) |
| Service | Calibration and preventive maintenance on site by Yamato-certified technicians or at Yamato's California service center |
Compare ULF Series Models
| Model | Capacity | Temperature range | Racks | Interior (W × D × H) | Exterior |
|---|---|---|---|---|---|
| ULF001CP | 2 cu.ft. | -40°C to -85°C | 6 racks | 17" × 14" × 14" (43 × 35 × 35 cm) | 25.25" × 25.75" × 40" (64 × 65 × 101 cm) |
| ULF101CP | 3 cu.ft. | -40°C to -85°C | 8 racks | 24" × 12" × 18" (60 × 30 × 45 cm) | 34.5" × 25.25" × 48" (87 × 64 × 121 cm) |
| ULF201CP (this model) | 5 cu.ft. | -40°C to -85°C | 15 racks | 30" × 18" × 16" (76 × 45 × 40 cm) | 40.5" × 31" × 47" (102 × 81 × 119 cm) |
| ULF301CP | 9 cu.ft. | -40°C to -85°C | 16 racks | 46" × 16" × 20" (116 × 40 × 50 cm) | 57.5" × 29" × 46.5" (146 × 73 × 116 cm) |
| ULF401CP | 12 cu.ft. | -40°C to -85°C | 27 racks | 55" × 19" × 20" (139 × 48 × 50 cm) | 65.5" × 32" × 47.5" (166 × 81 × 120 cm) |
| ULF501CP | 14 cu.ft. | -40°C to -85°C | 30 racks | 62" × 20" × 20" (157 × 50 × 50 cm) | 72.5" × 33" × 47.5" (184 × 83 × 120 cm) |
| ULF601CP | 17 cu.ft. | -40°C to -85°C | 36 racks | 69" × 20" × 21" (175 × 50 × 53 cm) | 81.25" × 33.5" × 48.5" (206 × 85 × 123 cm) |
| ULF701CP | 21 cu.ft. | -40°C to -80°C | 36 racks | 81" × 21.5" × 21" (205 × 54 × 53 cm) | 91" × 36" × 49" (231 × 91 × 124 cm) |
| ULF801CP | 22 cu.ft. | -40°C to -85°C | 36 racks | 67" × 19" × 30" (170 × 48 × 76 cm) | 98" × 36" × 43.5" (248 × 91 × 110 cm) |
| ULF901CP | 27 cu.ft. | -40°C to -80°C | 48 racks | 67" × 23" × 31.25" (170 × 57 × 79 cm) | 98" × 36" × 43.5" (248 × 91 × 110 cm) |
Ordering Information
| Catalog number | GTIN / UPC |
|---|---|
| ULF-201CP | 797059930425 |
| Manufacturer | Yamato Scientific |
| Manufacturer part number | ULF-201CP |
| UNSPSC | 41103000 — Ultra Low Freezer |
| HTS code | 8418.30.0000 |
| Export classification (ECCN) | EAR99 |
Documents & Downloads
- Yamato ULF Platinum Series Ultra-Low Freezer brochure (PDF, 290 KB)
- Yamato Scientific America product page
More in This Series
- Yamato ULF101CP Platinum Chest Style Ultra Low Freezers -40°C To -85°C, 3 cu.ft., Manual Defrost
- Yamato ULF001CP Platinum Chest Style Ultra Low Freezers -40°C To -85°C, 2 cu.ft., Manual Defrost
- Yamato ULF201UN Undercounter Ultra Low Freezers -40°C To -85°C, 3 cu.ft., Manual Defrost
- Yamato ULF301C Chest Style Ultra Low Freezers -40°C To -85°C, 9 cu.ft., Manual Defrost
- Yamato ULF401C Chest Style Ultra Low Freezers -40°C To -85°C, 12 cu.ft., Manual Defrost
- Yamato ULF101UN Undercounter Ultra Low Freezers -40°C To -85°C, 2 cu.ft., Manual Defrost
View all Ultra-Low Temperature Freezers →
Frequently Asked Questions
What temperature range does the ULF201CP reach?
The ULF201CP operates across a set-point range of -40°C to -85°C. A cascade refrigeration system with two hermetic compressors and CFC-free refrigerants delivers and holds these ultra-low temperatures.
What is the storage capacity and interior size?
The freezer offers 142 L (5 cu.ft.) of interior capacity and holds up to 15 racks. Interior dimensions are 30" × 18" × 16" (76 × 45 × 40 cm), with exterior dimensions of 40.5" × 31" × 47" (102 × 81 × 119 cm).
What power supply does this freezer require?
The ULF201CP runs on 115V, 208V, or 230V at 60 Hz, or 220V at 50/60 Hz, all single-phase. Confirm available facility power before installation to match the correct configuration.
How does the unit handle alarms and data monitoring?
A touch-screen controller displays set point and chamber temperature, logs data for download via USB or FTP, and shows a temperature graph.
Is the ULF201CP certified and where is it made?
The ULF201CP is UL Listed and built in the USA. It uses CFC-free R-508B and HCFC- and CFC-free R-404A refrigerants in an air-cooled cascade system requiring no liquid coolant.
What is the UNSPSC code for the Yamato ULF201CP?
The Yamato ULF201CP is classified under UNSPSC 41103000 (ultra low freezer).
Is there a spec sheet or brochure for the Yamato ULF201CP?
Yes. The Yamato ULF Platinum Series Ultra-Low Freezer brochure (290 KB PDF) is linked under Documents & Downloads on this page.
How does the Yamato ULF201CP compare with the other ULF Series models?
Yamato builds this ULF Series line in 10 sizes: 2 cu.ft. (ULF001CP), 3 cu.ft. (ULF101CP), 5 cu.ft. (ULF201CP), 9 cu.ft. (ULF301CP), 12 cu.ft. (ULF401CP), 14 cu.ft. (ULF501CP), 17 cu.ft. (ULF601CP), 21 cu.ft. (ULF701CP), 22 cu.ft. (ULF801CP) and 27 cu.ft. (ULF901CP). The comparison table on this page lists capacity, temperature range, racks, interior (w × d × h) and exterior side by side.
What are the interior dimensions of the Yamato ULF201CP?
The Yamato ULF201CP chamber measures 30" × 18" × 16" (76 × 45 × 40 cm) inside (W × D × H).
How many storage racks does the Yamato ULF201CP hold?
Yamato rates the ULF201CP at 15 racks in 142 L / 5 cu.ft. of storage.
What refrigeration system does the Yamato ULF201CP use?
The Yamato ULF201CP uses cascade type — two hermetic compressors, CFC-free R-508B and R-404A (CFC- & HCFC-free) refrigerant and manual defrost.
What optional accessories are available for the Yamato ULF201CP?
Yamato offers these options for the ULF201CP: CO₂ and LN₂ back-up system; racks; cold safety gloves.
What are the shipping dimensions and weight of the Yamato ULF201CP?
Yamato's shipping data lists the ULF201CP at 46 × 41 × 55 in and 525 lb packed.