Skip to product information
1 of 1

Yamato Scientific

Yamato ULF601C Chest Style Ultra Low Freezers -40°C To -85°C, 17 cu.ft., Manual Defrost

Yamato ULF601C Chest Style Ultra Low Freezers -40°C To -85°C, 17 cu.ft., Manual Defrost

Regular price $18,995.00
Regular price Sale price $18,995.00
Sale Sold out
Shipping calculated at checkout.
Title
View full details

Chest Style Ultra Low Freezers -40°C To -85°C, 17 cu.ft., Manual Defrost Overview

The Chest Style Ultra Low Freezers -40°C To -85°C, 17 cu.ft., Manual Defrost (model ULF601C) is a Yamato Scientific laboratory freezer built for long-term sample storage at ultra-low temperatures. This chest-style unit holds 480 L (17 cu.ft.) and operates across a -40°C to -85°C range. LabSupplies.com supplies it as an authorized dealer.

Construction pairs a 14-gauge zinc-coated galvanized steel chamber with a 16-gauge steel exterior finished in powder-coated cool gray. A cascade refrigeration system drives two hermetic compressors using CFC- and HCFC-free R-508B and R-404A refrigerants. Air-cooled condensing with two heavy-duty fans removes any need for liquid coolant.

Electrical options cover 115V, 208V, and 230V at 60 Hz single-phase, plus 220V at 50/60 Hz. Exterior dimensions measure 81.25 × 33.5 × 48.5 in., and shipping weight reaches 975 lbs. Built in the USA, the freezer carries UL Listed certification.

Key Features

  • Digital control system: microprocessor controller with a dual display showing set point and chamber temperature, scan button for setting, and tamper-proof lockout.
  • Battery-operated alarm: audible and visual signal on mechanical or electrical failure, with over- and under-temperature settings, a silencing switch, and a battery test switch.
  • Remote alarm relay: built-in relay lets the unit tie into a central building or facility monitoring system.
  • Power failure recovery: automatic timer restarts the freezer after power is restored.
  • Cascade refrigeration: two hermetic compressors and air-cooled condensing reach the full -40°C to -85°C range without liquid coolant.
  • Storage capacity: 480 L interior accommodates up to 36 racks, with a 1/2 in. access port for probes or wiring.

How to Choose the Right Ultra-Low Freezer

Matching an ultra-low freezer to a lab means weighing storage volume against the temperature class, site power, and floor space the unit demands. Review these axes before specifying a model.

  • Capacity: 480 L (17 cu.ft.) and 36-rack support determine how many samples a single unit can hold before a second purchase is needed.
  • Temperature range: a -40°C to -85°C span fits enzymes, cell lines, and biological samples that require deep-cold storage.
  • Control type: microprocessor digital control with dual display and tamper-proof lockout protects set points from accidental changes.
  • Voltage and site power: confirm the available circuit (115V, 208V, 230V at 60 Hz, or 220V at 50/60 Hz) matches your facility before ordering.
  • Footprint: verify the 81.25 × 33.5 × 48.5 in. exterior and 975 lb weight clear doorways and floor-load limits.
  • Safety and monitoring: battery-backed alarms, a remote alarm relay, and power-failure recovery safeguard samples during outages.

Specifications

Specification Detail
Capacity 17 cu.ft.
Temperature Range -40°C to -85°C
Defrost Manual
Interior Capacity 480 L / 17 cu.ft.
Rack Capacity 36 racks
Interior Dimensions 69" × 20" × 21" (175 × 50 × 53 cm)
Exterior Dimensions 81.25" × 33.5" × 48.5" (206 × 85 × 123 cm)
Temperature Control System Digital control with dual display (set point and chamber temperature); scan button for temperature setting; tamper-proof lockout
Refrigeration System Cascade type — two hermetic compressors
Refrigerant CFC-free R-508B and R-404A (CFC- & HCFC-free)
Condenser Air-cooled with two heavy-duty fans; no liquid coolant required
Alarm System Battery-operated alarm emits an audible and visual signal on mechanical or electrical failure; over- and under-temperature settings, alarm silencing switch, and battery test switch; relay provided for remote alarm hook-up
Power Failure Recovery Automatic timer system restarts the unit after a power failure
Electrical Requirements 115V / 208V / 230V, 60 Hz, 1-phase; 220V, 50/60 Hz, 1-phase
Optional Accessories Chart recorder; CO₂ and LN₂ back-up system; racks; cold safety gloves
Material Chamber is 14-ga. Zinc coated galvanized steel. Exterior is 16-ga. steel. Power coated cool gray
Country of Origin USA
GTIN (Barcode) 797059929894
Shipping Weight 975 lbs
Dimensions (L × W × H) 84 × 42 × 58 in
Component Size 17 CF
Other Certification UL Listed

Available Sizes and Configurations

SKU Configuration Pack
ULF-601C EA EA

Documentation

More in This Series

Why Buy From LabSupplies.com

LabSupplies.com sells the ULF601C as an authorized Yamato Scientific dealer, so every freezer ships as a genuine factory unit backed by the manufacturer warranty. Place your order directly online.

  • Authorized Yamato Scientific dealer: genuine equipment with full manufacturer warranty coverage.
  • In stock: ready to ship from USA inventory.
  • Lab-equipment specialists: dedicated support for specification and compatibility questions.

Frequently Asked Questions

What temperature range does the ULF601C reach?

The ULF601C operates from -40°C to -85°C. A cascade refrigeration system with two hermetic compressors and CFC- and HCFC-free R-508B and R-404A refrigerants maintains the deep-cold range for long-term sample storage.

How much storage capacity does this freezer offer?

Interior capacity is 480 L (17 cu.ft.), supporting up to 36 racks. Interior dimensions measure 69 × 20 × 21 in. (175 × 50 × 53 cm), giving a chest-style layout for organized sample retrieval.

What voltage does the ULF601C require?

Electrical options include 115V, 208V, and 230V at 60 Hz single-phase, plus 220V at 50/60 Hz single-phase. Confirm your available circuit before ordering to match the unit to your facility power.

What materials is the freezer built from?

The chamber is 14-gauge zinc-coated galvanized steel and the exterior is 16-gauge steel finished in powder-coated cool gray. The unit is built in the USA and is UL Listed.

How does the freezer protect samples during a power failure?

A battery-operated alarm provides audible and visual signals on mechanical or electrical failure, with over- and under-temperature settings and a remote alarm relay. An automatic timer restarts the unit once power returns.

What are the shipping dimensions and weight?

Exterior dimensions are 81.25 × 33.5 × 48.5 in. (206 × 85 × 123 cm) and the unit weighs 975 lbs. Verify doorway clearance and floor-load capacity before delivery.

Share:

Link copied to clipboard!

Questions | Support?