Skip to product information
1 of 1

Yamato Scientific

Yamato IC803CW General Purpose Incubator With Window 318L

Yamato IC803CW General Purpose Incubator With Window 318L

Regular price $4,770.00
Regular price Sale price $4,770.00
Sale Sold out
Shipping calculated at checkout.
Voltage
View full details

General Purpose Incubator With Window 318L Overview

The General Purpose Incubator With Window 318L (model IC803CW) is a natural convection incubator from Yamato Scientific, supplied through LabSupplies.com as an authorized dealer. Built around a 318 L chamber, this unit holds an operating temperature range of ambient +5 to 80°C. A dual-door design with a reinforced glass observation window lets staff inspect contents without opening the chamber and disturbing the internal atmosphere.

Air-jacket heating distributes warmth evenly across the stainless steel interior. PID microprocessor control paired with a K-thermocouple sensor delivers ±0.5°C accuracy at 37°C and ±1.0°C distribution. Glass fiber insulation surrounds the chamber, while the cold-rolled steel exterior carries a melamine resin baked finish. Heat is produced by a 0.7 kW iron-chrome wire heater.

Model IC803CW runs on 115V, and the IC813CW variant covers 220V installations. External dimensions measure 32 × 30 × 73 inches, with a shipping weight near 355 lbs and an interior of 600 × 530 × 1000 mm. Self-diagnostic functions, automatic overheat prevention, and a key lock support unattended operation. Country of origin is listed as CH per the manufacturer data.

Key Features

  • Dual-door observation: a reinforced glass inner door with a 250 × 700 mm window allows viewing without releasing chamber heat.
  • Air-jacket heating: natural convection through an air jacket distributes temperature evenly across the 318 L chamber.
  • Digital control and timer: an easy-to-read digital display with auto start/stop and quick auto stop manages set temperature and run time.
  • Temperature performance: PID microprocessor control with a K-thermocouple sensor maintains ±0.5°C accuracy at 37°C and ±1.0°C distribution.
  • Safety suite: self-diagnostic functions for sensor, display, and measured-temperature errors, plus automatic overheat prevention and a key lock.
  • Voltage options: IC803CW supports 115V circuits; IC813CW supports 220V circuits.

How to Choose the Right Incubator

Matching an incubator to a lab workflow comes down to chamber size, thermal performance, and the electrical and physical constraints of the install site. Use these criteria to confirm fit before ordering.

  • Capacity: the 318 L chamber suits sample batches and labware that need vertical and shelf space; confirm your throughput against the 600 × 530 × 1000 mm interior.
  • Temperature range: an ambient +5 to 80°C window covers common 37°C culture and elevated-temperature drying or conditioning tasks.
  • Control type: PID microprocessor control with K-thermocouple sensing favors applications needing tight, repeatable setpoints over simple thermostatic units.
  • Voltage: select IC803CW for 115V service or IC813CW for 220V service to match available site power.
  • Footprint: verify bench or floor clearance against the 32 × 30 × 73 inch exterior and 355 lb weight before delivery.
  • Safety: automatic overheat prevention, self-diagnostics, and a key lock matter for unattended overnight runs and shared-lab access control.

Specifications

Specification Detail
Capacity 318 L
Voltage 115V
System Natural convection
Operating Temperature Range ambient +5 to 80°C *1
Temperature Accuracy ±0.5°C (at 37°C) *2
Temperature Distribution ±1.0°C *2
Temperature Control System PID control by microprocessor
Sensor K-thermocouple
Interior Material Stainless steel
Exterior Material Cold-rolled steel plate with melamine resin baked finish
Heat Insulation Glass fiber
Operation Function Fixed temperature, auto start/stop, quick auto stop
Safety Devices Self-diagnostic functions (sensor error, display error, measured-temperature error); automatic overheat prevention
Heater Iron-chrome wire heater, 0.7 kW
Internal Dimensions 600 × 530 × 1000 mm
Inner Door Reinforced glass observation door (250 × 700 mm window)
Material Steel plate SPCC powder coating (exterior) Stainless steel (interior)
Country of Origin China
GTIN (Barcode) 797059927531
Shipping Weight 355 lbs
Dimensions (L × W × H) 32 × 30 × 73 in
Component Size 318 L

*1 No-load operation of bath only; maximum temperature varies with circumstances and operating conditions. *2 Measured under ambient temperature 23°C ±5°C, humidity 65%RH ±20%, per Yamato Scientific test conditions.

Available Sizes and Configurations

SKU Configuration Pack
IC-803CW 115V EA
IC-813CW 220V EA

Documentation

More in This Series

Why Buy From LabSupplies.com

LabSupplies.com is an authorized Yamato Scientific dealer, so every incubator ships as a genuine factory unit backed by the manufacturer warranty. Order directly online and our lab-equipment specialists are available for spec and configuration questions.

  • Authorized dealer: genuine Yamato Scientific equipment with full manufacturer warranty support.
  • In stock: available now and ready to process.
  • Ships from USA inventory: dispatched from domestic stock for predictable delivery.
  • Specialist support: dedicated lab-equipment staff for voltage, capacity, and installation questions.

Frequently Asked Questions

What is the operating temperature range of the IC803CW incubator?

The IC803CW operates from ambient +5 to 80°C. It uses PID microprocessor control with a K-thermocouple sensor for ±0.5°C accuracy at 37°C and ±1.0°C temperature distribution.

What is the chamber capacity and interior size?

Chamber capacity is 318 L. The interior measures 600 × 530 × 1000 mm, and the unit's exterior dimensions are 32 × 30 × 73 inches.

What is the difference between the IC803CW and IC813CW?

The only difference is electrical input. IC803CW runs on 115V and IC813CW runs on 220V; chamber, temperature range, control system, and construction are identical.

What power does this incubator require?

The incubator uses a 0.7 kW iron-chrome wire heater. Choose IC803CW for a 115V circuit or IC813CW for a 220V circuit to match site power.

What materials are used in the chamber and exterior?

The interior is stainless steel and the exterior is cold-rolled steel plate with a melamine resin baked finish. Glass fiber provides the chamber insulation.

Can contents be viewed without opening the incubator?

Yes. A dual-door system includes a reinforced glass inner door with a 250 × 700 mm window, letting staff view samples without disrupting the chamber atmosphere.

Share:

Link copied to clipboard!

Questions | Support?