Skip to product information
1 of 5

TrippNT

TrippNT Lab Entry Changing Station | All-in-One Gowning & PPE Wall Station 50193

TrippNT Lab Entry Changing Station | All-in-One Gowning & PPE Wall Station 50193

Regular price $483.88
Regular price Sale price $483.88
Sale Sold out
Shipping calculated at checkout.

TrippNT Lab Entry Changing Station — All-in-One Wall-Mount Gowning and PPE Staging Station for Cleanroom, BSL-2, and Laboratory Entry Compliance

The TrippNT Lab Entry Changing Station (SKU 50193) is a comprehensive, single-panel wall-mount gowning station that consolidates every component of a standard laboratory entry transition — apparel storage, safety glasses staging, glove dispensing, coat hanging, and consumable supply organization — into a single 26¾″ W × 20¾″ H × 7⅜″ D footprint. The station is built around a central bank of three bins with hinged clear acrylic doors, each bin large enough to hold a standard apparel dispenser stock (hairnets, booties, beard covers, or folded gowns) with the acrylic door providing dust protection and visible stock-level monitoring without opening the compartment. Three coat and gown hooks mounted across the top of the unit accommodate lab coat staging and personal item hanging during the gowning sequence. A single glove box holder is integrated into one side panel, staging the correct PPE at the point where hands are gloved during entry. Four open small-format cubbies and one long open shelf complete the feature set, providing staging positions for visitors’ personal items, additional safety supplies, and entry-specific consumables.

Constructed primarily from 1/2-inch HDPE (the main structural body), white PVC (side and secondary panels), and 1/8-inch clear acrylic (bin doors and display panels), the 50193 delivers the chemical resistance and rigid structure that HDPE is specified for in demanding laboratory environments — the same polymer class used in TrippNT’s cart platforms. Keyhole back mounting with included hardware supports installation on painted drywall, FRP gowning room panels, stainless steel panels, and epoxy-coated block wall. The all-plastic construction has no metal fasteners exposed to the interior surfaces, eliminating corrosion risk in high-humidity or chemical-splash environments. Ships fully assembled, 5.85 lb empty weight. For facilities requiring only one or two apparel categories at a single wall position (not the full gowning-station format), the 50101 2-in-1 and 50127 3-in-1 apparel dispensers (LS Batches 03 and 04) are the correct products.

Technical Specifications

Specification Detail
Material (Body) 1/2″ HDPE, 1/4″ White PVC, 1/8″ Clear Acrylic
Color / Finish White body, clear acrylic doors
Bins with Acrylic Doors 3 (dust-protected, clear-front visibility)
Coat / Gown Hooks 3
Glove Box Holder 1 (integrated side panel)
Small Open Compartments 4 cubbies
Long Open Shelf 1
Mount Type Keyhole wall mount — hardware included
Product Dimensions (W × H × D) 26¾″ × 20¾″ × 7⅜″
Product Weight 5.85 lb
Shipping Carton (L × W × H) 27″ × 13″ × 23″
Shipping Weight 10 lb (Small Parcel)
UPC 692041659219
HTS Code 3926.9
Country of Origin United States (Kansas City, MO)

Laboratory and Clinical Applications

The TrippNT 50193 is specified for comprehensive gowning and entry compliance in: pharmaceutical manufacturing gowning rooms and entry vestibules (21 CFR Part 211, EU GMP Annex 1, ISO 14644 — single-station setup for small-to-medium lab entries), USP <797>/<800> sterile compounding ante-room entry points (full gowning sequence in one footprint), food and beverage production gowning areas (HACCP, FSMA, SQF, and FDA food defense compliance), BSL-2 laboratory entry vestibules (full PPE transition in a compact wall format), university research building corridor gowning stations (multi-user shared PPE entry point), hospital clinical laboratory entry vestibules (visitor and contractor gowning), dental and veterinary group practice staff entry points, cleanroom gowning vestibules in ISO 5–8 controlled environments, research facility visitor management programs, and school laboratory preparation rooms (class entry PPE staging). Also used at manufacturing cell entry points in medical device, semiconductor, and food processing environments where a single-unit gowning station must support a small team of 3–10 personnel per shift.

Product Documentation

Made in the U.S.A. & Lifetime Guarantee

Proudly manufactured in the United States by TrippNT. This lab entry changing station is backed by a 100% Lifetime Guarantee, ensuring it is a permanent asset for your laboratory. Institutional pricing and bulk discounts are available for universities, hospital systems, and government agencies.

Frequently Asked Questions

What is the capacity of each of the three dust-protected bins?

Each of the three center bins with hinged clear acrylic doors is sized to hold a standard apparel dispenser stock unit: a 500-count hairnet bag, a 100-pair bootie/shoe cover stack (folded), a 100-count beard cover stack, or a 50-count disposable gown folded stack. The acrylic door hinges fully upward for top-loading refill access; the bin front dispenses items from an open or bottom-slot access depending on configuration. For reference, the 50193 center bin dimensions are similar to one bay of the 50101 2-in-1 apparel dispenser. If higher-capacity per-category staging is needed at the same entry point, the 50193 can be supplemented with a 50101 or 50151 dispenser mounted adjacent on the same wall.

How many people can the 50193 support simultaneously during a gowning sequence?

The 50193 is a single-station format — it supports one person gowning at a time, making it the correct specification for entries with a controlled one-person-at-a-time entry protocol (most pharmaceutical GMP and BSL-2 gowning anteroom formats). For team entries where 3–5 people enter a controlled zone simultaneously, multiple 50193 units spaced along a corridor, or a combination of 50193 (for coats and structured bins) plus individual apparel dispensers (50127 or 50151), provides the correct multi-position coverage. The 3 coat hooks limit concurrent garment staging to 3 people per unit without increasing unit count.

View full details

Questions | Support?