Caplugs® Evergreen
1.0 mL Sample Cups, Tethered Caps, HDPE, Natural, Hitachi/Roche Compatible — 127-1758-020 | 1,000/Bag | Caplugs® Evergreen
1.0 mL Sample Cups, Tethered Caps, HDPE, Natural, Hitachi/Roche Compatible — 127-1758-020 | 1,000/Bag | Caplugs® Evergreen
Couldn't load pickup availability
1.0 mL Tapered Flat Bottom Roche-Compatible Sample Cups with Tethered Caps — HDPE, Natural, 1,000/Bag
| Quick Reference — 127-1758-020 | |
|---|---|
| Volume | 1.0 mL |
| Geometry | Tapered Flat Bottom |
| Cap Type | Tethered (attached, cannot be lost) |
| OEM Compatibility | Roche / Hitachi — verified fit |
| Material | High-Density Polyethylene (HDPE) |
| Color | Natural |
| Sterility | Non-Sterile |
| Pack Size | 1,000 / Bag |
| Per-Cup Cost | $0.0520 at $51.92/Bag |
| Price | $51.92 / Bag |
Technical Narrative
The Caplugs® Evergreen 127-1758-020 is a 1.0 mL tapered flat bottom sample cup with a permanently tethered hinged cap, precision-molded from virgin High-Density Polyethylene (HDPE) to the dimensional specification of Roche / Hitachi 717, 736, 737, and 747 autoanalyzer flat-bottom cup positions. The tethered cap design is the key differentiator: the cap remains physically attached to the cup body at all times — eliminating cap-loss events during high-throughput rack loading and unloading that cause delays, sample identification errors, and contamination risks on busy clinical chemistry processing benches.
HDPE construction provides superior chemical resistance over Polystyrene for aggressive reagent applications, with excellent compatibility across saline buffers, dilute acids, EDTA, and standard clinical chemistry preservatives. The clear natural HDPE enables direct visual sample volume assessment and optical clarity for photometric autoanalyzer measurement. HDPE's natural rigidity maintains the tapered flat-bottom geometry under centrifugation and rack handling forces, ensuring consistent aspiration depth and dead-volume minimization across all 1,000 cups in the bag.
At $51.92 per 1,000-count Bag — $0.0520 per cup — the delivers Roche/Hitachi-compatible tethered-cap cup quality at bulk procurement pricing. The 127-1758 family is available in three colors for color-coded workflow integration: 127-1758-B20 (HDPE Blue, $51.92/Bag); 127-1758-Y20 (HDPE Yellow, $51.92/Bag). Single-vendor procurement across all three colors eliminates compatibility risk when mixing cup batches on the same analyzer.
Technical Specifications — Caplugs® Evergreen
| Specification | Value |
|---|---|
| Part Number | |
| Caplugs Item # | |
| Volume | 1.0 mL |
| Geometry | Tapered Flat Bottom |
| Cap Style | Tethered — permanently attached, hinged closure |
| OEM Compatibility | Roche / Hitachi 717/736/737/747 — primary design target |
| Material | High-Density Polyethylene (HDPE) |
| Color | Natural |
| Sterility | Non-Sterile |
| Pack Size | 1,000 / Bag |
| Reorder Unit | Bag of 1,000 |
| Application | Roche/Hitachi autoanalyzer sample cups, open system chemistry |
| BPA / Phthalate | BPA-free; no phthalate plasticizers |
| Country of Origin | Made in U.S.A. (California) |
Roche / Hitachi Analyzer Compatibility —
The is engineered to the Roche / Hitachi tapered flat bottom cup specification. Primary compatibility:
| Manufacturer | Compatible Models | Notes |
|---|---|---|
| Roche Diagnostics | Hitachi 717, 736, 737, 747 (primary OEM target) | Tapered flat bottom geometry matches Hitachi/Roche cup rack specification exactly |
| Roche Diagnostics | cobas c 111, cobas c 311/501/502 | Tethered cap prevents cap loss during high-throughput rack loading on cobas platforms |
| Beckman Coulter | CX3, CX4, CX5 Delta, DxC 600i/700i | Flat bottom fits flat-cup positions; verify cup well dimensions |
| Siemens Healthineers | Dimension RxL, XL, Vista (flat cup positions) | Confirm flat-bottom position availability in instrument manual |
| Olympus / Beckman | AU400, AU600, AU640 (flat cup positions) | Tapered geometry aids secure seating in AU-series flat-cup rack positions |
| Generic | Any open-system analyzer accepting 1.0 mL tapered flat bottom cups | Always validate cup OD, height, and cap clearance before large-volume purchase |
The tethered cap must clear the analyzer's cup transport mechanism during rack loading. Validate cap clearance height against your instrument manual before large-volume purchase. Free samples available — see the procurement section below.
Chemical Resistance — High-Density Polyethylene (HDPE)
The is molded from virgin High-Density Polyethylene (HDPE). HDPE provides broader chemical resistance than PS, including better tolerance for concentrated acids and saline preservatives.
| Reagent / Condition | Compatibility |
|---|---|
| Dilute acids (<10%) | Excellent |
| Dilute alkalies (pH <12) | Excellent |
| Saline / buffer solutions | Excellent |
| Short-chain alcohols (EtOH, MeOH) | Excellent |
| DMSO (brief contact) | Good |
| Concentrated acids (>50%) | Good |
| Ketones (acetone, MEK) | Not recommended |
| Chlorinated solvents | Avoid |
| Autoclave (121°C / 15 psi) | Compatible |
Clinical & Research Laboratory Applications
The tethered-cap sample cups serve hospital and reference laboratory Roche and Hitachi clinical chemistry analyzer fleets, STAT and high-throughput core laboratories where cap-loss events cause workflow disruption, clinical chemistry reference labs standardizing on tethered-cap format to eliminate loose cap management, outreach laboratory networks centralizing on Roche/Hitachi-compatible consumables, and biotech and pharmaceutical QC departments running open-system Hitachi-platform assays. The 1,000/Bag bulk format supports high-throughput processing at scale.
U.S. Manufacturing, Quality & Institutional Procurement
Every Caplugs® Evergreen lot is precision-molded at our California manufacturing facility and subject to rigorous dimensional inspection — verifying cup geometry, wall thickness, and cap-tether integrity that autoanalyzer performance demands. We supply reference laboratories, hospital systems, biotech firms, and federal procurement offices under institutional pricing programs with blanket-order support and same-day shipping on stocked inventory. Request a compatibility sample below to validate fit with your instrument before committing to volume.
Frequently Asked Questions — Caplugs® Evergreen
Why choose a tethered cap cup over a standard open-top sample cup?
Tethered cap cups keep the cap physically attached to the cup body via a flexible hinge — the cap cannot be separated, lost, or mixed up between cups during high-throughput rack loading. On analyzers like the Hitachi 717/736 series where loose caps are a documented source of workflow delays and sample ID errors, tethered-cap formats reduce cap-management labor and contamination risk. The hinged cap closes securely after aspiration for sample archiving without requiring a separate loose cap to track.
Is the a direct replacement for Roche / Hitachi OEM cups?
The is engineered to the tapered flat-bottom cup dimensional specification used on Roche / Hitachi 717, 736, 737, and 747 analyzers and cobas c-series platforms that accept this cup format. As with all OEM-equivalent consumables, validate cup OD, height, tethered-cap clearance, and aspiration depth with your instrument manual and run a trial set before full-volume purchase. Free samples are available — see the procurement section below.
Are the cups BPA-free and phthalate-free?
Yes. Both the cup body and tethered cap are molded from virgin High-Density Polyethylene (HDPE) containing no BPA and no phthalate plasticizers — suitable for clinical chemistry, regulated laboratory, and accredited diagnostic environments.
Share