Laboratory Equipment Guides & Resources

Rotary Evaporator Setup and Operation Guide

Rotary Evaporator Setup and Operation Guide

Rotary evaporator setup: glassware assembly, vacuum and bath settings by solvent, and bump traps, with Yamato RE-202-A and REV-202M-A part numbers.

Rotary Evaporator Setup and Operation Guide

Rotary evaporator setup: glassware assembly, vacuum and bath settings by solvent, and bump traps, with Yamato RE-202-A and REV-202M-A part numbers.

Lab Flask Types Explained: Erlenmeyer, Volumetric, Round-Bottom

Lab Flask Types Explained: Erlenmeyer, Volumetr...

Lab flask types compared: Erlenmeyer for mixing and culture, volumetric for exact-volume solutions, round-bottom for heating and distillation.

Lab Flask Types Explained: Erlenmeyer, Volumetr...

Lab flask types compared: Erlenmeyer for mixing and culture, volumetric for exact-volume solutions, round-bottom for heating and distillation.

Graduated Cylinder Accuracy: Class A vs Class B

Graduated Cylinder Accuracy: Class A vs Class B

Graduated cylinder accuracy per ASTM E1272: a 100 mL Class A reads ±0.50 mL, Class B ±1.00 mL. Tolerances 5 to 2000 mL, glass vs plastic, Globe 8300.

Graduated Cylinder Accuracy: Class A vs Class B

Graduated cylinder accuracy per ASTM E1272: a 100 mL Class A reads ±0.50 mL, Class B ±1.00 mL. Tolerances 5 to 2000 mL, glass vs plastic, Globe 8300.

Micropipette Calibration & Maintenance Guide

Micropipette Calibration & Maintenance Guide

Micropipette Calibration & Maintenance Guide Micropipette calibration is the single most overlooked source of systematic error in laboratory data. A pipette that reads 100µL but consistently delivers 96µL will corrupt...

Micropipette Calibration & Maintenance Guide

Micropipette Calibration & Maintenance Guide Micropipette calibration is the single most overlooked source of systematic error in laboratory data. A pipette that reads 100µL but consistently delivers 96µL will corrupt...

Serological vs Transfer Pipettes: When to Use Each

Serological vs Transfer Pipettes: When to Use Each

Serological Pipettes vs Transfer Pipettes: When to Use Each Choosing between serological pipettes and transfer pipettes comes down to 3 things: volume precision, sterility requirements, and workflow speed. We've seen...

Serological vs Transfer Pipettes: When to Use Each

Serological Pipettes vs Transfer Pipettes: When to Use Each Choosing between serological pipettes and transfer pipettes comes down to 3 things: volume precision, sterility requirements, and workflow speed. We've seen...

The 5 Best Centrifuge Tubes for PCR and Molecular Biology

The 5 Best Centrifuge Tubes for PCR and Molecul...

The best centrifuge tubes for PCR and molecular biology aren't the cheapest tubes in the catalog — they're the ones that won't contaminate your reactions, won't crack at 14,000 ×g,...

The 5 Best Centrifuge Tubes for PCR and Molecul...

The best centrifuge tubes for PCR and molecular biology aren't the cheapest tubes in the catalog — they're the ones that won't contaminate your reactions, won't crack at 14,000 ×g,...