Skip to product information
1 of 1

Caplugs® Evergreen

8125–01 L Microplates, PS, Natural, Thermo Fisher/Corning Compatible — 290-8125-01L | 15/Box | Caplugs® Evergreen

8125–01 L Microplates, PS, Natural, Thermo Fisher/Corning Compatible — 290-8125-01L | 15/Box | Caplugs® Evergreen

Regular price $77.67
Regular price Sale price $77.67
Sale Sold out
Shipping calculated at checkout.
View full details

24-Well Microplate Lids — Polystyrene, Natural/Transparent, Autoclavable, 15/Box (290-8125-01L)

These 24-well polystyrene microplate lids are designed to fit standard SBS/ANSI-footprint 24-well plates, delivering evaporation control, contamination protection, and gas-exchange management during cell culture incubation, virus propagation, organoid culture, and sample archiving workflows. Supplied non-sterile in 15/Box (105/Case) format, part number 290-8125-01L is autoclave-compatible at 121°C / 15 psi — enabling sterilization before use in contamination-sensitive primary cell culture and biosafety-level applications where relying on non-sterile supply is not acceptable. The natural transparent PS construction allows visual assessment of well filling and cell confluency without removing the lid.

Technical Specifications

Specification Value
Part Number (MPN) 290-8125-01L
Well Format 24-Well SBS/ANSI Standard Footprint
Material Polystyrene (PS)
Color Natural (Transparent)
Sterility Non-Sterile
Autoclave Compatibility Compatible — 121°C / 15 psi
Verified Plate Compatibility Caplugs® Evergreen 290-8124-01F 24-well flat-bottom plate
Pack Size 15/Box (105/Case)
BPA / Phthalates BPA-free; no phthalate plasticizers
Country of Origin USA

Applications

  • Cell culture incubation — reduces contamination risk during extended adherent and suspension culture in CO₂ incubators
  • Virus propagation — covers CPE assay plates during viral replication to prevent cross-contamination between wells
  • Organoid culture — protects 3D organoids in Matrigel or basement membrane extract from desiccation during multi-day incubation
  • Drug treatment incubation — maintains sterile conditions over compound-treated cell plates during treatment periods
  • Evaporation control — reduces medium evaporation from edge wells in long-duration covered incubations
  • Sample storage and transport — protects well contents from contamination and physical damage between experimental sessions

Compatibility

These lids are engineered to fit the standard SBS/ANSI microplate footprint used by 24-well plates across the major labware platforms, including Thermo Fisher and Corning formats. The precision friction-fit geometry seats securely against standard 24-well plate flanges — stable enough to prevent accidental dislodgement during incubator stacking and plate transport while still permitting the CO₂/O₂ gas exchange required for mammalian cell culture atmosphere equilibration. Compatibility with Caplugs® Evergreen 290-8124-01F 24-well flat-bottom plates has been directly verified. As lid-to-plate tolerances can vary across manufacturers, confirming fit with your specific plate brand before committing to high-volume procurement is always recommended.

Chemical Resistance

Reagent / Condition Compatibility
Aqueous cell culture media / buffers Excellent
Saline and physiological solutions Excellent
Dilute acids and bases Good — short-term contact
Ethanol >70% Not recommended
Acetone Not recommended
Aromatic / chlorinated solvents Not recommended
Autoclave (121°C / 15 psi) Compatible

Quality & Procurement

Made in USA, Caplugs® Evergreen microplate lids are manufactured from BPA-free, phthalate-free polystyrene resin under ISO 9001 quality management. LabSupplies.com is an authorized Caplugs® Evergreen dealer and ships from USA inventory, with case-quantity pricing available to support high-plate-count cell culture programs, institutional purchasing agreements, and grant-funded laboratory budgets.

Frequently Asked Questions

Can these lids be autoclaved before use in sterile cell culture?
Yes — the polystyrene construction is autoclave-compatible at 121°C / 15 psi, making it appropriate to sterilize the lids before use in primary cell culture, virus propagation, and other contamination-sensitive workflows where a non-sterile supply is unacceptable.

Will these lids fit plates from Thermo Fisher, Corning, or other major manufacturers?
The lids are designed for the standard SBS/ANSI 24-well microplate footprint used across the industry, including Thermo Fisher and Corning platforms. Fit with the Caplugs® Evergreen 290-8124-01F flat-bottom plate has been directly verified. Because lid-to-flange tolerances vary by manufacturer, confirming physical fit with your specific plate brand before large orders is recommended.

Do the lids allow gas exchange during CO₂ incubation?
Yes — the friction-fit design provides a secure seal against accidental dislodgement while still permitting the passive CO₂/O₂ exchange needed to maintain atmosphere equilibration for mammalian cell culture in a CO₂ incubator.

Are these lids available in case quantities for high-throughput labs?
Yes — in addition to the 15/Box format, these lids are available as a 105/Case configuration, providing per-lid economics suited to programs that allocate a dedicated lid to each plate for the full duration of multi-day experiments.

Questions | Support?