Skip to product information
1 of 1

Accuris

Accuris SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020 | 200–800 nm, dsDNA 0.5 pg/µL to 15,000 ng/µL

Accuris SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020 | 200–800 nm, dsDNA 0.5 pg/µL to 15,000 ng/µL

Regular price $13,405.21
Regular price Sale price $13,405.21
Sale Sold out
Shipping calculated at checkout.
Power
View full product details

The SmartDrop XF NS1020 pairs a full-spectrum 200–800 nm absorbance spectrophotometer with a blue-excitation fluorometer for low-concentration DNA work. Path lengths of 0.05, 0.2 and 1.0 mm extend the absorbance range to 0.04–300 A (10 mm equivalent), reading dsDNA up to 15,000 ng/µL and BSA up to 360 mg/mL from 0.5–2.0 µL samples. The fluorometer excites at 460 ± 20 nm, collects 525–570 nm emission and detects dsDNA down to 0.5 pg/µL. A 7-inch touch screen runs the instrument without a PC.

Key features

  • Absorbance 200–800 nm in 1 nm steps, xenon flash lamp
  • Path lengths 0.05, 0.2 and 1.0 mm; range 0.04–300 A
  • dsDNA up to 15,000 ng/µL and BSA up to 360 mg/mL by absorbance
  • Fluorometer: 460 ± 20 nm excitation, 525–570 nm emission
  • Fluorescence sensitivity to 0.5 pg/µL dsDNA
  • 7-inch touch screen, USB export, results in under 6 seconds

Specifications

Brand Accuris
Catalog number NS1020 / NS1020-E
Display 7 in touch screen
Sample Volume 0.5–2.0 µL
Path Length 0.05 mm, 0.2 mm, 1.0 mm
Light Source Xenon flash lamp
Detector 2,048-element linear silicon CCD array
Wavelength Range 200–800 nm (1 nm steps)
Absorbance Range 0.04–300 A (10 mm equivalent)
Lower Limit of Detection dsDNA: 2 ng/µL; BSA: 0.1 mg/mL
Upper Limit of Detection dsDNA: 15,000 ng/µL; BSA: 360 mg/mL
Fluorescence Excitation / Emission 460 ± 20 nm / 525–570 nm
Fluorescence Sensitivity dsDNA: 0.5 pg/µL
Detection Time < 6 seconds
Electrical 24 V DC, 2 A; 25 W
Dimensions (W × D × H) 8.2 × 12.6 × 7.3 in (20.8 × 32.0 × 18.6 cm)
Weight 7.9 lb (3.6 kg)
Warranty 2 years

Ordering information

Catalog number Power
NS1020 115V, US plug
NS1020-E 230V, European plug

Questions about the SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020

What sample volume and detection range does the SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020 work with?

The SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020 uses 0.5–2.0 µL of sample, with a lower limit of detection of dsDNA: 2 ng/µL; BSA: 0.1 mg/mL and an absorbance range of 0.04–300 A (10 mm equivalent).

Is the SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020 available with a European plug?

Yes. NS1020-E is the European-plug version of NS1020: NS1020 is 115V with a US plug and NS1020-E is 230V with a European plug.

Documents