{"product_id":"trippnt-polyethylene-fume-hood-shelf-36-inch-50315","title":"TrippNT Polyethylene HDPE Fume Hood Shelf 36-Inch | Bleach-Resistant Heavy-Duty Staging 50315","description":"\u003ch2\u003eTechnical Narrative\u003c\/h2\u003e\n\u003cp\u003eThe TrippNT 50315 Polyethylene Fume Hood Shelf is the heavy-duty material tier for 36″ fume hood interior staging, constructed from ¼″ white high-density polyethylene (HDPE) rather than PVC — providing a substantially higher chemical resistance profile and superior load-bearing capacity for environments where the standard PVC shelf (50215) is inadequate. HDPE’s chemical resistance to concentrated sulfuric acid, hydrochloric acid, sodium hydroxide, bleach, sani-wipes, and peracetic acid makes the 50315 the specification of choice for acid-heavy organic synthesis hoods, pharmaceutical GMP hoods with validated bleach-cleaning protocols, food-and-beverage GMP food-contact adjacent hoods, and any hood application where aggressive cleaning chemistries are cycled through the interior as part of an SOP-documented decontamination procedure.\u003c\/p\u003e\n\u003cp\u003eDimensions are 36″ W x 8″ H x 5¾″ D with a 4.84 lb finished weight — nearly twice the mass of the PVC 50215 (2.51 lb) at the same footprint, reflecting the higher density of HDPE and thicker effective wall gauge. The open-frame design preserves laminar airflow passthrough, maintaining ASHRAE 110-2016 fume hood face velocity compliance. Ships fully assembled. Backed by TrippNT’s 100% Lifetime Guarantee. For lower-chemical-exposure environments, specify the more economical white PVC 50215 at the same dimensions.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003e¼″ White HDPE (High-Density Polyethylene)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\/Finish\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShelf Width\u003c\/td\u003e\n\u003ctd\u003e36″ (3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Lip\u003c\/td\u003e\n\u003ctd\u003e1″ perimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow Design\u003c\/td\u003e\n\u003ctd\u003eOpen-frame; laminar flow passes freely through shelf\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleaning Compatibility\u003c\/td\u003e\n\u003ctd\u003eBleach, sani-wipes, peracetic acid, IPA, dilute acids\/bases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFree-standing interior fume hood shelf\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e36″ x 8″ x 5¾″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e4.84 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Carton (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e10″ x 12″ x 40″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e692041659318\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHTS Code\u003c\/td\u003e\n\u003ctd\u003e3926.90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States — Kansas City, MO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLaboratory and Clinical Applications\u003c\/h2\u003e\n\u003cp\u003eThe 50315 is deployed across regulated and research environments requiring chemical-resistant interior fume hood shelving, including pharmaceutical API synthesis and acid-chemistry hoods, GMP QC hoods with validated bleach decontamination cycles, organic chemistry acid-reaction and workup hoods, industrial chemical QC acid and base staging hoods, food-and-beverage regulatory chemistry hoods with HACCP cleaning requirements, environmental analytical chemistry oxidative-digest preparation hoods, forensic chemistry acid-digestion hoods, semiconductor fab chemical handling hoods with HF or strong acid exposures, nuclear research and isotope-handling hoods requiring high-level disinfection, and biotechnology protein-chemistry hoods with periodic NaOH caustic cleaning. HDPE is also the material of choice when the installation will receive commercial kitchen-grade sanitizers or quaternary ammonium at concentrations that cause PVC to plasticize over time.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.trippnt.com\/shop\/50315-polyethylene-fume-hood-shelf-1056\/document\/915\" target=\"_blank\" rel=\"noopener\"\u003eSales Sheet — 50315 Polyethylene Fume Hood Shelf (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMade in the U.S.A. \u0026amp; Lifetime Guarantee\u003c\/h2\u003e\n\u003cp\u003eProudly manufactured in the United States by TrippNT. This fume hood shelf is backed by a 100% Lifetime Guarantee, ensuring it is a permanent asset for your laboratory. Institutional pricing and bulk discounts are available for universities, hospital systems, and government agencies.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhen should I specify the HDPE 50315 over the PVC 50215 — what are the key decision drivers for the premium material?\u003c\/h3\u003e\n\u003cp\u003eSpecify the HDPE 50315 when any of the following apply: (1) the hood interior is periodically cleaned with bleach, peracetic acid, sani-wipes, or aggressive sanitizers as part of a documented SOP — HDPE is classified resistant to these at a broad concentration range while PVC can soften or surface-craze at repeated high-concentration exposures; (2) the hood works with concentrated strong acids (H\u0026amp;sub2;SO\u0026amp;sub4;, HCl, HNO\u0026amp;sub3;) where spill probability is real and penetration of liquid between shelf and content is possible; (3) a heavier point load is regularly placed on the shelf and the higher mechanical density of HDPE is needed; (4) an institutional specification or procurement standard explicitly requires HDPE or “chemical-resistant polyethylene” rather than PVC. In moderate-use hoods with only 70% IPA and quaternary ammonium cleaning, the PVC 50215 at less than half the cost is the appropriate specification.\u003c\/p\u003e\n\u003ch3\u003eDoes the HDPE 50315 maintain the same ASHRAE 110-2016 compliance characteristics as the PVC 50215 — is the airflow geometry identical?\u003c\/h3\u003e\n\u003cp\u003eYes. Both the HDPE 50315 and PVC 50215 share the same open-frame 36″ x 8″ x 5¾″ geometry with the same laminar airflow passthrough design and 1″ safety lip. From an ASHRAE 110 airflow perspective, the two are functionally interchangeable in the same 36″ hood. The HDPE unit is approximately 2.3 lb heavier, which is relevant for shelf stability under dynamic loading but has no airflow compliance implication. Annual ASHRAE 110 testing should be conducted with the shelf in its loaded configuration regardless of material specification.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"TrippNT Polyethylene Fume Hood Shelf 36 Inch — 50315\",\n  \"image\": [\n    \"https:\/\/www.trippnt.com\/web\/image\/product.product\/966\/image_1024\/%5B50315%5D%20Polyethylene%20Fume%20Hood%20Shelf?unique=1848b2b\",\n    \"https:\/\/www.trippnt.com\/web\/image\/product.image\/550\/image_1024\/50315.2.webp?unique=cb3de9b\",\n    \"https:\/\/www.trippnt.com\/web\/image\/product.image\/551\/image_1024\/50315.3.webp?unique=cb3de9b\",\n    \"https:\/\/www.trippnt.com\/web\/image\/product.image\/552\/image_1024\/50315.4.webp?unique=cb3de9b\",\n    \"https:\/\/www.trippnt.com\/web\/image\/product.image\/553\/image_1024\/50315.5.webp?unique=cb3de9b\",\n    \"https:\/\/www.trippnt.com\/web\/image\/product.image\/2371\/image_1024\/Polyethylene%20Fume%20Hood%20Shelf?unique=1848b2b\"\n  ],\n  \"description\": \"TrippNT 50315 Polyethylene Fume Hood Shelf. White 1\/4-inch HDPE open-frame interior fume hood shelf, 36 inches wide, 8 inches tall, 5.75-inch depth, 1-inch safety lip. Chemical-resistant to bleach, peracetic acid, and strong acids. Made in USA. Lifetime Guarantee.\",\n  \"sku\": \"50315\",\n  \"gtin12\": \"692041659318\",\n  \"brand\": {\"@type\": \"Brand\", \"name\": \"TrippNT\"},\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"TrippNT, Inc.\",\n    \"address\": {\n      \"@type\": \"PostalAddress\",\n      \"streetAddress\": \"10991 N Airworld Drive\",\n      \"addressLocality\": \"Kansas City\",\n      \"addressRegion\": \"MO\",\n      \"postalCode\": \"64153\",\n      \"addressCountry\": \"US\"\n    }\n  },\n  \"countryOfOrigin\": \"US\",\n  \"material\": \"1\/4-inch White HDPE\",\n  \"weight\": {\"@type\": \"QuantitativeValue\", \"value\": \"4.84\", \"unitCode\": \"LBR\"},\n  \"offers\": {\n    \"@type\": \"Offer\",\n    \"priceCurrency\": \"USD\",\n    \"price\": \"291.67\",\n    \"availability\": \"https:\/\/schema.org\/InStock\",\n    \"warranty\": \"Lifetime\"\n  }\n}\n\u003c\/script\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"When should I specify the HDPE 50315 over the PVC 50215 — what are the key decision drivers for the premium material?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Specify the HDPE 50315 when the hood interior is periodically cleaned with bleach, peracetic acid, sani-wipes, or aggressive sanitizers per a documented SOP; when the hood works with concentrated strong acids where spill probability is real; or when an institutional spec explicitly requires HDPE. In moderate-use hoods with only IPA or quaternary ammonium cleaning, the PVC 50215 at less than half the cost is the appropriate specification.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the HDPE 50315 maintain the same ASHRAE 110-2016 compliance characteristics as the PVC 50215 — is the airflow geometry identical?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. Both share the same 36 x 8 x 5.75-inch open-frame geometry with identical laminar airflow passthrough design and 1-inch safety lip. From an ASHRAE 110 perspective, the two are functionally interchangeable in the same 36-inch hood. The HDPE unit is approximately 2.3 lb heavier with no airflow compliance implication.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"TrippNT","offers":[{"title":"Default Title","offer_id":48516379967720,"sku":"50315","price":291.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/5B50315_5D_20Polyethylene_20Fume_20Hood_20Shelf.jpg?v=1778120377","url":"https:\/\/labsupplies.com\/products\/trippnt-polyethylene-fume-hood-shelf-36-inch-50315","provider":"LabSupplies.com","version":"1.0","type":"link"}