{"product_id":"nxt-power-integrity-pro-desktop-ups-250va-nptu250-gl-n","title":"NXT Power Integrity PRO Desktop UPS 250VA — Isolated Line-Interactive Power Conditioner (NPTU250-GL-N)","description":"\u003ch2\u003eNXT Power Integrity PRO Desktop UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity PRO Desktop UPS (NPTU250-GL-N)\u003c\/strong\u003e delivers 250 VA \/ 200 W of isolated, line-interactive backup power. It shields sensitive bench instruments, point-of-sale terminals, and back-office IT from spikes, sags, and outages. Inside the chassis, a low-impedance isolation transformer, surge diverter, and noise filter clean incoming power before disturbances reach the load.\u003c\/p\u003e\n\u003cp\u003eUnlike strip-style battery backups, this unit pairs galvanic isolation with true sine wave output for sensitive loads. NXT GROUND circuitry eliminates ground loops that trigger system lock-ups on networked benches and registers. A 24 VDC output rail powers compatible printers directly, removing the external adapter that clutters most counters.\u003c\/p\u003e\n\u003cp\u003eEvery Integrity PRO Desktop unit is listed to UL1778 and backed by a three-year NXT Power warranty. That warranty covers components and internal batteries from the ship date. Standard USB communication supports monitored shutdown on Windows hosts.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLine-interactive uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU250-GL-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive, true sine wave, isolated (AC and DC output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e250 VA \/ 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (range 96–144 VAC), 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15P, fixed 6 ft line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e(5) NEMA 5-15R plus (1) terminal block for DC output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output\u003c\/td\u003e\n\u003ctd\u003e24.0 VDC @ 3.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±10% of nominal (on mains input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e≥90% AC-AC; ≥82% DC-AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e6–9 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate valve-regulated sealed lead-acid (VRLA); Qty 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 7 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 90%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤40 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e10.5 × 5.8 × 12.6 in (267 × 147 × 318 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 31 lb (14 kg); Shipping 37 lb (17 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, FCC Part 15 Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNPTU250-GL-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity PRO Desktop UPS, 120 VAC 60 Hz\u003c\/td\u003e\n\u003ctd\u003e250 VA \/ 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed more headroom? The NPTU400-GL-N steps up to 400 VA \/ 320 W in the same isolated desktop form factor.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated Desktop UPS\u003c\/h2\u003e\n\u003cp\u003eMatching a desktop UPS to a bench comes down to load type, not just outage runtime. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size the UPS above your combined load; the NPTU250-GL-N supports up to 200 W continuous.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — an isolation transformer blocks common-mode noise and ground loops that plain battery strips pass straight through.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — sensitive instruments and PFC power supplies favor true sine wave over simulated output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC printer support\u003c\/strong\u003e — the 24 VDC rail drives compatible printers without a separate adapter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC 60 Hz circuit and a NEMA 5-15 receptacle at the point of use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eIsolated desktop UPS units protect the low-draw electronics that fill modern labs and service counters. Data loggers, network switches, single-board controllers, pH and conductivity meters, and imaging peripherals all benefit from clean, conditioned power within the 200 W rating. Ground-loop elimination keeps networked instruments from locking up mid-run.\u003c\/p\u003e\n\u003cp\u003eBeyond the bench, the Integrity PRO Desktop suits point-of-sale terminals, ticket and receipt printers, credit-card readers, and security cameras. Conditioned power reduces nuisance faults on shared circuits, while battery backup carries connected gear through brief interruptions for an orderly shutdown.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for higher-capacity and rack options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n\u003cli\u003eNPTU400-GL-N — the 400 VA \/ 320 W sibling in the same isolated desktop chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003eEach NPTU250-GL-N ships as a single conditioned UPS with a fixed 6 ft line cord and internal battery installed. LabSupplies.com is an authorized NXT Power dealer and ships from US inventory. \u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NPTU250-GL-N run on a standard 120 V wall outlet?\u003c\/strong\u003e\u003cbr\u003eYes. It uses a NEMA 5-15P plug and accepts 120 VAC input across a 96–144 VAC range at 60 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the output waveform?\u003c\/strong\u003e\u003cbr\u003eTrue sine wave. That makes it suitable for PFC power supplies and instruments that reject stepped or simulated waveforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a standard battery backup?\u003c\/strong\u003e\u003cbr\u003eIt adds a low-impedance isolation transformer and NXT GROUND conditioning. Those block common-mode noise and ground loops that ordinary battery strips pass through to the load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 24 VDC output power?\u003c\/strong\u003e\u003cbr\u003eThe 24 VDC rail (up to 3.0 A) drives compatible printers directly, eliminating a separate external adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal battery from the date of shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity PRO Desktop UPS 250VA (NPTU250-GL-N)\",\n  \"sku\": \"NPTU250-GL-N\",\n  \"mpn\": \"NPTU250-GL-N\",\n  \"brand\": { \"@type\": \"Brand\", \"name\": \"NXT Power\" },\n  \"description\": \"Isolated, line-interactive 250 VA \/ 200 W desktop UPS with true sine wave output, low-impedance isolation transformer, NXT GROUND conditioning, and 24 VDC output. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-desktop-ups-250va-nptu250-gl-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity PRO Desktop UPS 400VA (NPTU400-GL-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-desktop-ups-400va-nptu400-gl-n\"\n  },\n  \"offers\": {\n    \"@type\": \"Offer\",\n    \"priceCurrency\": \"USD\",\n    \"price\": \"422.00\",\n    \"availability\": \"https:\/\/schema.org\/InStock\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-desktop-ups-250va-nptu250-gl-n\",\n    \"seller\": { \"@type\": \"Organization\", \"name\": \"LabSupplies.com\" }\n  },\n  \"dateModified\": \"2026-07-08\"\n}\n\u003c\/script\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    { \"@type\": \"Question\", \"name\": \"Does the NPTU250-GL-N run on a standard 120 V wall outlet?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Yes. It uses a NEMA 5-15P plug and accepts 120 VAC input across a 96–144 VAC range at 60 Hz.\" } },\n    { \"@type\": \"Question\", \"name\": \"What is the output waveform?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"True sine wave, suitable for PFC power supplies and instruments that reject stepped or simulated waveforms.\" } },\n    { \"@type\": \"Question\", \"name\": \"How is this different from a standard battery backup?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"It adds a low-impedance isolation transformer and NXT GROUND conditioning, which block common-mode noise and ground loops that ordinary battery strips pass through to the load.\" } },\n    { \"@type\": \"Question\", \"name\": \"What does the 24 VDC output power?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"The 24 VDC rail supplies up to 3.0 A and drives compatible printers directly, eliminating a separate external adapter.\" } },\n    { \"@type\": \"Question\", \"name\": \"How long is the warranty?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Three years, covering components and the internal battery from the date of shipment.\" } }\n  ]\n}\n\u003c\/script\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    { \"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/labsupplies.com\" },\n    { \"@type\": \"ListItem\", \"position\": 2, \"name\": \"NXT Power UPS\", \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\" },\n    { \"@type\": \"ListItem\", \"position\": 3, \"name\": \"Integrity PRO Desktop UPS 250VA (NPTU250-GL-N)\" }\n  ]\n}\n\u003c\/script\u003e\u003c\/p\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48714049913064,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/images_ee3b18e5-ec26-42c2-afd1-15718be9401d.jpg?v=1783527263","url":"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-desktop-ups-250va-nptu250-gl-n","provider":"LabSupplies.com","version":"1.0","type":"link"}