{"product_id":"nxt-power-integrity-max-ups-6000va-nptu6000-ho-n","title":"NXT Power Integrity Max UPS 6000VA — Isolated Online Double-Conversion Hardwired UPS (NPTU6000-HO-N)","description":"\u003ch2\u003eNXT Power Integrity Max UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max UPS (NPTU6000-HO-N)\u003c\/strong\u003e delivers 6000 VA \/ 5400 W of isolated, online double-conversion power for demanding hardwired facility installs. An IGBT rectifier and inverter regenerate output continuously through an internal isolation transformer. A manual bypass keeps the load powered during service.\u003c\/p\u003e\n\u003cp\u003eThe 208 VAC input and 240\/208\/120 VAC output both connect hardwired, terminated by an electrician at install. This model has no plug. RS-232, USB, and DB-9 dry contacts cover local monitoring, and an internal SNMP adapter is available for network alerts.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and a three-year NXT Power warranty cover components and internal batteries. Sixteen internal VRLA batteries form the 192 VDC bus behind a unit rated for 36 A of continuous input current.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS), hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU6000-HO-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion true sine wave output, IGBT rectifier and inverter, internal isolation transformer, manual bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e6000 VA \/ 5400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208 VAC nominal (200\/208\/220\/230\/240 VAC range, 176–275 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eHardwired (no plug); electrician-terminated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e36 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e240 \/ 208 \/ 120 VAC, hardwired multi-tap\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±1.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥91.0%; DC-AC ≥88.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManual Bypass\u003c\/td\u003e\n\u003ctd\u003eIncluded; transformer voltage regulation 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 16 (192 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 5 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB, DB-9 dry contacts; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage −15 to 55 °C, transit −15 to 60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤55 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e1822 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e28.4 × 11.8 × 32.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 276 lb (125 kg); Shipping 342 lb (155 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, IEC 62040-1, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU6000-HO-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max UPS, hardwired, 208 VAC in \/ 240-208-120 VAC out\u003c\/td\u003e\n\u003ctd\u003e6000 VA \/ 5400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a different capacity? The NPTU2200-HO-N and NPTU4200-HO-N cover 2200 W and 4200 W, while the NPTU10.0-HO-N scales up to 9000 W.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Hardwired Facility UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a hardwired Max UPS is a facility decision, not a plug-in one. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined facility load; the NPTU6000-HO-N supports up to 5400 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, with a manual bypass for service.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits facility instrument and IT loads that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, DB-9 dry contacts, and an optional SNMP adapter support monitored, networked shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm 208 VAC hardwired facility distribution sized for 36 A; an electrician must terminate the connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eThe largest consolidated equipment rooms in a typical lab or clinical facility fit the NPTU6000-HO-N's 5400 W rating. Multi-rack instrument suites, imaging clusters, and shared IT infrastructure all run on continuously isolated, regenerated power. Manual bypass matters most at this scale, where scheduled maintenance can't afford to drop the load.\u003c\/p\u003e\n\u003cp\u003eFacilities with dedicated 208 VAC distribution engineered for heavy, continuous draw are the intended fit. Installation requires a licensed electrician to terminate both input and output; there is no wall outlet at this capacity tier.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU2200-HO-N and NPTU4200-HO-N — 2200 W and 4200 W options in the same hardwired Max chassis family.\u003c\/li\u003e\n  \u003cli\u003eNPTU10.0-HO-N — the 9000 W model at the top of the Max line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFacility-scale, sample-critical loads this hardwired UPS class conditions and bridges through outages:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/ultra-low-temperature-freezers\"\u003eUltra-Low Temperature Freezers\u003c\/a\u003e — shield -80 °C sample storage from surges, sags, and brief outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/vnhoetby\/integrity-max-user-manual-revision-b-02-03-21.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIntegrity Max User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU6000-HO-N ships as a hardwired double-conversion UPS with internal batteries installed; a licensed electrician terminates the input and output connections. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your facility.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NPTU6000-HO-N plug into a wall outlet?\u003c\/strong\u003e\u003cbr\u003eNo. It's a hardwired unit; a licensed electrician terminates both the 208 VAC input and the 240\/208\/120 VAC output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can it support?\u003c\/strong\u003e\u003cbr\u003eUp to 6000 VA \/ 5400 W continuous, powered from sixteen internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the manual bypass do?\u003c\/strong\u003e\u003cbr\u003eIt routes power around the UPS electronics during service, keeping the connected load powered without interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232, USB, and DB-9 dry contacts are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max UPS 6000VA (NPTU6000-HO-N)\",\n  \"sku\": \"NPTU6000-HO-N\",\n  \"mpn\": \"NPTU6000-HO-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 6000 VA \/ 5400 W hardwired UPS with true sine wave output, internal isolation transformer, and manual bypass for the largest consolidated equipment rooms. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-6000va-nptu6000-ho-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max UPS 10kVA (NPTU10.0-HO-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-10000va-nptu10-0-ho-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the NPTU6000-HO-N plug into a wall outlet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. It's a hardwired unit; a licensed electrician terminates both the 208 VAC input and the 240\/208\/120 VAC output.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can it support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 6000 VA \/ 5400 W continuous, powered from sixteen internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does the manual bypass do?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It routes power around the UPS electronics during service, keeping the connected load powered without interruption.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232, USB, and DB-9 dry contacts are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max UPS 6000VA (NPTU6000-HO-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817341160,"sku":"NPTU6000-HO-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-max_0000_integrity-max-2-10-kvamax-front_67946bcd-6d2e-4694-adb9-1232bc0d8391.png?v=1784387008","url":"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-6000va-nptu6000-ho-n","provider":"LabSupplies.com","version":"1.0","type":"link"}