{"product_id":"nxt-power-integrity-max-ups-2200va-nptu2200-ho-n","title":"NXT Power Integrity Max UPS 2200VA — Isolated Online Double-Conversion Hardwired UPS (NPTU2200-HO-N)","description":"\u003ch2\u003eNXT Power Integrity Max UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max UPS (NPTU2200-HO-N)\u003c\/strong\u003e delivers 2200 VA \/ 2200 W of isolated, online double-conversion power for hardwired facility installations. An IGBT rectifier and inverter regenerate clean output continuously through an internal isolation transformer. A manual bypass allows service without dropping the connected load.\u003c\/p\u003e\n\u003cp\u003eThis is a hardwired unit: 208 VAC input and a 240\/208\/120 VAC output are both terminated by an electrician at install. No plug or wall outlet is involved. RS-232, USB, and DB-9 dry contacts cover local monitoring, with an internal SNMP adapter available for network alerts.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and NXT Power's three-year warranty cover components and internal batteries. Sixteen internal VRLA batteries form the 192 VDC bus, sized for a short, clean ride-through rather than extended standby runtime.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS), hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU2200-HO-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion true sine wave output, IGBT rectifier and inverter, internal isolation transformer, manual bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e2200 VA \/ 2200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208 VAC nominal (200\/208\/220\/230\/240 VAC range, 176–275 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eHardwired (no plug); electrician-terminated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e240 \/ 208 \/ 120 VAC, hardwired multi-tap\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±1.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥91.0%; DC-AC ≥88.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManual Bypass\u003c\/td\u003e\n\u003ctd\u003eIncluded; transformer voltage regulation 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 16 (192 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 23 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB, DB-9 dry contacts; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage −15 to 55 °C, transit −15 to 60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤55 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e742 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e28.4 × 11.8 × 32.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 276 lb (125 kg); Shipping 342 lb (155 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, IEC 62040-1, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU2200-HO-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max UPS, hardwired, 208 VAC in \/ 240-208-120 VAC out\u003c\/td\u003e\n\u003ctd\u003e2200 VA \/ 2200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed more capacity? The NPTU4200-HO-N, NPTU6000-HO-N, and NPTU10.0-HO-N scale up to 4200 W, 5400 W, and 9000 W in the same hardwired Max chassis family.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Hardwired Facility UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a hardwired Max UPS is a facility decision, not a plug-in one. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined facility load; the NPTU2200-HO-N supports up to 2200 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, with a manual bypass for service.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits facility instrument and IT loads that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, DB-9 dry contacts, and an optional SNMP adapter support monitored, networked shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm 208 VAC hardwired facility distribution; an electrician must terminate the connection, as there is no plug.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eFacility-scale instrument and IT loads that exceed a Max LT unit's capacity fit the NPTU2200-HO-N's 2200 W rating. Equipment rooms consolidating multiple instrument racks, imaging suites, and small data closets all run on continuously isolated, regenerated power. Manual bypass keeps that load powered during scheduled UPS service.\u003c\/p\u003e\n\u003cp\u003eFacilities already wired for 208 VAC distribution are the natural fit, since this model has no plug and connects directly to a dedicated circuit. An electrical contractor should size and terminate the hardwired connection as part of installation.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU4200-HO-N — steps up to 4200 W in the same hardwired Max chassis family.\u003c\/li\u003e\n  \u003cli\u003eNPTU6000-HO-N and NPTU10.0-HO-N — 5400 W and 9000 W models for the largest facility loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFacility-scale, sample-critical loads this hardwired UPS class conditions and bridges through outages:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/ultra-low-temperature-freezers\"\u003eUltra-Low Temperature Freezers\u003c\/a\u003e — shield -80 °C sample storage from surges, sags, and brief outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/vnhoetby\/integrity-max-user-manual-revision-b-02-03-21.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIntegrity Max User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU2200-HO-N ships as a hardwired double-conversion UPS with internal batteries installed; a licensed electrician terminates the input and output connections. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your facility.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NPTU2200-HO-N plug into a wall outlet?\u003c\/strong\u003e\u003cbr\u003eNo. It's a hardwired unit; a licensed electrician terminates both the 208 VAC input and the 240\/208\/120 VAC output at install.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does double conversion with manual bypass mean?\u003c\/strong\u003e\u003cbr\u003eOutput is continuously regenerated from an isolated DC bus, and the manual bypass lets a technician service the unit without dropping the load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can it support?\u003c\/strong\u003e\u003cbr\u003eUp to 2200 VA \/ 2200 W continuous, powered from sixteen internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232, USB, and DB-9 dry contacts are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max UPS 2200VA (NPTU2200-HO-N)\",\n  \"sku\": \"NPTU2200-HO-N\",\n  \"mpn\": \"NPTU2200-HO-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 2200 VA \/ 2200 W hardwired UPS with true sine wave output, internal isolation transformer, and manual bypass for facility-scale loads. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-2200va-nptu2200-ho-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max UPS 4200VA (NPTU4200-HO-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-4200va-nptu4200-ho-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the NPTU2200-HO-N plug into a wall outlet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. It's a hardwired unit; a licensed electrician terminates both the 208 VAC input and the 240\/208\/120 VAC output at install.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does double conversion with manual bypass mean?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Output is continuously regenerated from an isolated DC bus, and the manual bypass lets a technician service the unit without dropping the load.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can it support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 2200 VA \/ 2200 W continuous, powered from sixteen internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232, USB, and DB-9 dry contacts are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max UPS 2200VA (NPTU2200-HO-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817242856,"sku":"NPTU2200-HO-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-max_0000_integrity-max-2-10-kvamax-front.png?v=1784386999","url":"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-2200va-nptu2200-ho-n","provider":"LabSupplies.com","version":"1.0","type":"link"}