{"product_id":"nxt-power-integrity-max-rt-ups-800va-nptu800-or-n","title":"NXT Power Integrity Max R\/T UPS 800VA — Isolated Online Double-Conversion Rackmount 2U UPS (NPTU800-OR-N)","description":"\u003ch2\u003eNXT Power Integrity Max R\/T UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max R\/T UPS (NPTU800-OR-N)\u003c\/strong\u003e delivers 800 VA \/ 720 W of isolated, online double-conversion power from a compact 2U chassis. A continuous double-conversion topology regenerates output continuously, so connected gear sees zero transfer gap during a mains event. An internal isolation transformer removes common-mode noise before it reaches rack-mounted electronics.\u003c\/p\u003e\n\u003cp\u003eSix NEMA 5-15R outlets accept standard equipment cords. A factory-default 120 VAC input covers most North American racks, and 100 VAC is selectable where needed. RS-232 and USB ports handle local monitoring, and an internal SNMP slot is available for network alerts.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and a three-year NXT Power warranty cover components and internal batteries. Three internal VRLA batteries deliver a 36 VDC bus, sized for a short, clean ride-through rather than extended runtime.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU800-OR-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion, true sine wave output, internal isolation transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e800 VA \/ 720 W (666\/599 W @100VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC factory default (100 VAC selectable), 90–150 VAC range above 75% load, 50\/60 Hz auto-detect\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15P, fixed 6 ft line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e10.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e(6) NEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±2.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥84.0%; DC-AC ≥82.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 3 (36 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 8 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB, DB-9 dry contacts; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage −15 to 55 °C, transit −15 to 60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤50 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e467 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e3.46 × 17.32 × 27.68 in (88 × 440 × 703 mm), 2U rack-tower\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 63 lb (29 kg); Shipping 72 lb (33 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU800-OR-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max R\/T UPS, 2U rack-tower, 120 VAC\u003c\/td\u003e\n\u003ctd\u003e800 VA \/ 720 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed more headroom? The NPTU1100-OR-N and NPTU1500-OR-N step up to 990 W and 1290 W in the same 2U rack-tower chassis.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated Rack Tower UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a rack-tower UPS comes down to rack load and how it's isolated, not just runtime. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined rack load; the NPTU800-OR-N supports up to 720 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — online double-conversion output stays isolated and regenerated at all times, not just after a transfer event.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits networking and instrument power supplies that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, and an optional SNMP slot support monitored shutdown across a rack.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC circuit and rack space for a 2U, NEMA 5-15P-powered unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eRack-mounted lab and IT equipment benefits most from the NPTU800-OR-N's compact 2U footprint. Network switches, small servers, and single-board data-acquisition racks stay within its 720 W rating while double-conversion output removes upstream noise. Shared-rack wiring is exactly where ground-loop noise tends to accumulate.\u003c\/p\u003e\n\u003cp\u003eInstrument racks in imaging suites and diagnostic labs suit the same profile, especially alongside networking gear. Zero transfer-time double conversion matters most for equipment that faults on even a brief gap.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU1100-OR-N — the 990 W step-up in the same 2U rack-tower chassis.\u003c\/li\u003e\n  \u003cli\u003eNPTU1500-OR-N — the 1290 W model at the top of the R\/T line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRack-mounted data and monitoring systems this UPS protects:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/multi-channel-data-loggers\"\u003eMulti-Channel Data Loggers\u003c\/a\u003e — uninterrupted logging through outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/swift-sensors-wireless-monitoring\"\u003eSwift Sensors Wireless Monitoring\u003c\/a\u003e — keep monitoring gateways online during a power event.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/0arbrf2t\/022-00051-nptu800-to-1500-o-r-user-manual-rev-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNPTU800 to NPTU1500-O-R User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU800-OR-N ships as a complete rack-tower UPS with rack ears, tower feet, and internal batteries installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your rack.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NPTU800-OR-N mount in a standard rack?\u003c\/strong\u003e\u003cbr\u003eYes. It ships as a 2U unit with rack ears and tower feet, so it mounts in a standard rack or stands alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does double-conversion mean for connected equipment?\u003c\/strong\u003e\u003cbr\u003eOutput power is continuously regenerated from the isolated DC bus, so there's no transfer gap when mains power fails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it run on 100 VAC instead of 120 VAC?\u003c\/strong\u003e\u003cbr\u003eYes, 100 VAC is a selectable configuration; 120 VAC ships as the factory default.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max R\/T UPS 800VA (NPTU800-OR-N)\",\n  \"sku\": \"NPTU800-OR-N\",\n  \"mpn\": \"NPTU800-OR-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 800 VA \/ 720 W rack-tower UPS with true sine wave output and internal isolation transformer. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-rt-ups-800va-nptu800-or-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max R\/T UPS 1100VA (NPTU1100-OR-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-rt-ups-1100va-nptu1100-or-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the NPTU800-OR-N mount in a standard rack?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. It ships as a 2U unit with rack ears and tower feet, so it mounts in a standard rack or stands alone.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does double-conversion mean for connected equipment?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Output power is continuously regenerated from the isolated DC bus, so there's no transfer gap when mains power fails.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can it run on 100 VAC instead of 120 VAC?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, 100 VAC is a selectable configuration; 120 VAC ships as the factory default.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max R\/T UPS 800VA (NPTU800-OR-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771816980712,"sku":"NPTU800-OR-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-max-rt-standing-0_web.png?v=1784386966","url":"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-rt-ups-800va-nptu800-or-n","provider":"LabSupplies.com","version":"1.0","type":"link"}