{"product_id":"nxt-power-integrity-max-lt-ups-3000va-nptu3000-o-ns","title":"NXT Power Integrity Max LT UPS 3000VA 208\/240VAC — Isolated Online Double-Conversion UPS (NPTU3000-O-NS)","description":"\u003ch2\u003eNXT Power Integrity Max LT UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max LT UPS (NPTU3000-O-NS)\u003c\/strong\u003e delivers 2700 VA \/ 2430 W of isolated, online double-conversion power from a 208\/240 VAC-capable input. Field-configurable input lets one unit serve either a 208 VAC or 240 VAC circuit, shipping factory-set to 208 VAC. This continuous double-conversion topology regenerates output from an isolated DC bus.\u003c\/p\u003e\n\u003cp\u003eA detachable NEMA L6-30P cord draws from the selected circuit. Output delivers 240\/120 VAC across one L6-30R, one L6-20R, one 6-20R duplex, and two 5-20R duplex receptacles. RS-232, USB, and an optional internal SNMP adapter cover local and networked monitoring.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and NXT Power's three-year warranty cover components and internal batteries. AC-DC-AC efficiency reaches 84%, matching the rest of the Max LT line despite the higher input voltage.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU3000-O-NS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion, true sine wave output, internal isolation transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e2700 VA \/ 2430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208 VAC or 240 VAC, user-configurable (factory set for 208 VAC); 187–264 VAC range above 75% load, 50\/60 Hz auto-detect\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eNEMA L6-30P, detachable 8 ft line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e15.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e240 \/ 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e(1) NEMA L6-30R, (1) L6-20R, (1) 6-20R duplex, (2) 5-20R duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±2.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥84.0%; DC-AC ≥80.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 6 (72 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 3 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage\/transit −10 to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤55 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e1575 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e22.0 × 8.9 × 22.8 in (560 × 227 × 580 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 132 lb (60 kg); Shipping 145 lb (66 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU3000-O-NS\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max LT UPS, tower, 208\/240 VAC (field-configurable)\u003c\/td\u003e\n\u003ctd\u003e2700 VA \/ 2430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed standard 120 VAC service instead? The NPTU2000-O-N and NPTU3000-O-N cover 1728 W and 2430 W on 120 VAC circuits.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated Max LT UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a Max LT UPS comes down to facility load and available circuits. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined load; the NPTU3000-O-NS supports up to 2430 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, unlike backups that only switch after a transfer event.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits instrument and IT power supplies that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, and an optional SNMP adapter support monitored, networked shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm 208 VAC or 240 VAC facility distribution and a NEMA L6-30 receptacle; input is field-configurable between the two.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eFacilities with 208 VAC or 240 VAC distribution are the deciding factor for the NPTU3000-O-NS. Equipment rooms already wired for 208\/240 VAC service can run instrument racks and IT infrastructure at 2430 W. Configurable input means one part number covers both common facility voltages.\u003c\/p\u003e\n\u003cp\u003eMulti-instrument suites and consolidated server rooms benefit from the mixed 240\/120 VAC output. It feeds both 240 V equipment and standard 120 V peripherals from a single unit. Continuous double conversion keeps that combined load isolated and regenerated throughout an outage.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU2000-O-N and NPTU3000-O-N — 1728 W and 2430 W models for standard 120 VAC circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHigher-draw, sample-critical equipment this UPS class conditions and bridges through outages:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/ultra-low-temperature-freezers\"\u003eUltra-Low Temperature Freezers\u003c\/a\u003e — shield -80 °C sample storage from surges, sags, and brief outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/m3tocuin\/nxt-power-2k3k-120v-pf0-9-english-user-manual-a5-_192321172093000.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIntegrity Max LT User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU3000-O-NS ships as a complete double-conversion UPS with a detachable line cord and internal batteries installed, field-configurable between 208 VAC and 240 VAC input. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your facility.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this two different products for 208V and 240V input?\u003c\/strong\u003e\u003cbr\u003eNo, it's one unit with field-configurable input voltage, shipped factory-set to 208 VAC and switchable to 240 VAC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can the NPTU3000-O-NS support?\u003c\/strong\u003e\u003cbr\u003eUp to 2700 VA \/ 2430 W continuous, powered from six internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat output does it provide?\u003c\/strong\u003e\u003cbr\u003e240\/120 VAC across one L6-30R, one L6-20R, one 6-20R duplex, and two 5-20R duplex receptacles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max LT UPS 3000VA 208\/240VAC (NPTU3000-O-NS)\",\n  \"sku\": \"NPTU3000-O-NS\",\n  \"mpn\": \"NPTU3000-O-NS\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 2700 VA \/ 2430 W UPS with field-configurable 208\/240 VAC input, true sine wave output, and internal isolation transformer. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-lt-ups-3000va-nptu3000-o-ns\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max LT UPS 3000VA (NPTU3000-O-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-lt-ups-3000va-nptu3000-o-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is this two different products for 208V and 240V input?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No, it's one unit with field-configurable input voltage, shipped factory-set to 208 VAC and switchable to 240 VAC.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can the NPTU3000-O-NS support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 2700 VA \/ 2430 W continuous, powered from six internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What output does it provide?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"240\/120 VAC across one L6-30R, one L6-20R, one 6-20R duplex, and two 5-20R duplex receptacles.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max LT UPS 3000VA 208\/240VAC (NPTU3000-O-NS)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817210088,"sku":"NPTU3000-O-NS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-lt-1_10k_e5268bf2-5165-4eb0-9609-bf47212fcd8c.png?v=1784386993","url":"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-lt-ups-3000va-nptu3000-o-ns","provider":"LabSupplies.com","version":"1.0","type":"link"}