{"product_id":"nxt-power-integrity-max-lt-ups-2000va-nptu2000-o-n","title":"NXT Power Integrity Max LT UPS 2000VA — Isolated Online Double-Conversion UPS (NPTU2000-O-N)","description":"\u003ch2\u003eNXT Power Integrity Max LT UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max LT UPS (NPTU2000-O-N)\u003c\/strong\u003e delivers 1920 VA \/ 1728 W of isolated, online double-conversion power for equipment that outgrows a rack-tower unit. Continuous double conversion regenerates output from an isolated DC bus, so connected systems see zero transfer gap during a mains event. Six internal batteries form a 72 VDC bus sized for a clean, dependable ride-through.\u003c\/p\u003e\n\u003cp\u003eA fixed NEMA 5-20P cord draws from a standard 120 VAC circuit, and output splits across one L5-30R plus six NEMA 5-20R receptacles. Where site power requires it, a 100 VAC configuration is also available. RS-232, USB, and an optional internal SNMP adapter cover local and networked monitoring.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and NXT Power's three-year warranty cover components and internal batteries. Efficiency reaches 84% AC-DC-AC, keeping heat output manageable in an equipment room running continuously.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU2000-O-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion, true sine wave output, internal isolation transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e1920 VA \/ 1728 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (100 VAC optional, derated), 90–150 VAC range above 75% load, 50\/60 Hz auto-detect\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-20P, fixed 6 ft line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e16.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e(1) NEMA L5-30R and (6) NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±2.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥84.0%; DC-AC ≥80.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 6 (72 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 4 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage\/transit −10 to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤55 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e1110 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e22.0 × 8.9 × 22.8 in (560 × 227 × 580 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 132 lb (60 kg); Shipping 145 lb (66 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU2000-O-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max LT UPS, tower, 120 VAC\u003c\/td\u003e\n\u003ctd\u003e1920 VA \/ 1728 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed more headroom? The NPTU3000-O-N steps up to 2430 W on a dedicated 120 VAC circuit, and the NPTU3000-O-NS covers 208\/240 VAC facilities.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated Max LT UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a Max LT UPS comes down to facility load and available circuits. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined load; the NPTU2000-O-N supports up to 1728 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, not only after a transfer event.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits instrument and IT power supplies that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, and an optional SNMP adapter support monitored, networked shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC circuit and NEMA 5-20 receptacle; a 100 VAC configuration is available where needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eLarger analytical systems that a desktop or rack-tower unit can't carry fit the NPTU2000-O-N's 1728 W rating. GC-MS and LC-MS front ends, along with multi-instrument benches drawing steady combined current, run on continuously isolated, regenerated power. Equipment rooms consolidating several instrument racks see the same benefit at a shared point of use.\u003c\/p\u003e\n\u003cp\u003eIT infrastructure supporting instrument data pipelines, including small server clusters and network cores, draws similarly steady load at this capacity. Continuous double conversion protects that infrastructure from the brief switchover gaps that simpler backups can't fully eliminate.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU3000-O-N — steps up to 2430 W on a dedicated NEMA L5-30 circuit.\u003c\/li\u003e\n  \u003cli\u003eNPTU3000-O-NS — the 208\/240 VAC configuration for facilities without standard 120 VAC distribution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHigher-draw, sample-critical equipment this UPS class conditions and bridges through outages:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/ultra-low-temperature-freezers\"\u003eUltra-Low Temperature Freezers\u003c\/a\u003e — shield -80 °C sample storage from surges, sags, and brief outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/m3tocuin\/nxt-power-2k3k-120v-pf0-9-english-user-manual-a5-_192321172093000.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIntegrity Max LT 2000\/3000 (120VAC) User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU2000-O-N ships as a complete double-conversion UPS with a fixed line cord and internal batteries installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your equipment room.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can the NPTU2000-O-N support?\u003c\/strong\u003e\u003cbr\u003eUp to 1920 VA \/ 1728 W continuous, powered from six internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does double conversion differ from a standard UPS?\u003c\/strong\u003e\u003cbr\u003eOutput is continuously regenerated from an isolated DC bus rather than switched during an outage, so there's no transfer gap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat outlets does it provide?\u003c\/strong\u003e\u003cbr\u003eOne NEMA L5-30R and six NEMA 5-20R receptacles, fed from a fixed NEMA 5-20P input cord.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max LT UPS 2000VA (NPTU2000-O-N)\",\n  \"sku\": \"NPTU2000-O-N\",\n  \"mpn\": \"NPTU2000-O-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 1920 VA \/ 1728 W UPS with true sine wave output and internal isolation transformer for larger instrument systems. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-lt-ups-2000va-nptu2000-o-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max LT UPS 3000VA (NPTU3000-O-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-lt-ups-3000va-nptu3000-o-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can the NPTU2000-O-N support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 1920 VA \/ 1728 W continuous, powered from six internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does double conversion differ from a standard UPS?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Output is continuously regenerated from an isolated DC bus rather than switched during an outage, so there's no transfer gap.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What outlets does it provide?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"One NEMA L5-30R and six NEMA 5-20R receptacles, fed from a fixed NEMA 5-20P input cord.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max LT UPS 2000VA (NPTU2000-O-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817111784,"sku":"NPTU2000-O-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-lt-1_10k.png?v=1784386983","url":"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-lt-ups-2000va-nptu2000-o-n","provider":"LabSupplies.com","version":"1.0","type":"link"}