{"product_id":"lw-scientific-dry-bath-incubator-2ml","title":"LW Scientific Digital Dry Bath Incubator - DBL-40PL-02DP | 40-Place 2mL PID Control","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eWaiting for a water bath to heat up — then worrying about contamination, evaporation, and weekly cleaning — wastes time that belongs at the bench. The LW Scientific DBL-40PL-02DP Digital Dry Bath Incubator eliminates every one of those problems. This USA-made benchtop heater delivers precise, stable temperatures from ambient +5°C to 150°C using PID microprocessor control, so your enzyme digestions, PCR prep, and cell lysis reactions hit the exact temperature they need — and stay there.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eTwo interchangeable 20-place anodized aluminum blocks hold a total of 40 microcentrifuge tubes (1–2 mL) simultaneously. The bright LED display shows both setpoint and real-time temperature at a glance. Durable metal construction, suction-cup feet for bench stability, and a universal 90–240 VAC power adapter mean this incubator is ready to work in any laboratory in the world — straight out of the box.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e40-Tube Capacity:\u003c\/strong\u003e Two 20-place anodized aluminum heat blocks accommodate 40 microcentrifuge tubes (1–2 mL) at once, letting you run full-plate PCR prep or batch enzyme reactions without waiting for a second cycle.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePID Microprocessor Control:\u003c\/strong\u003e Digital PID regulation maintains setpoint accuracy within ±0.5°C, eliminating the temperature overshoot and drift common in analog dry baths.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWide Temperature Range:\u003c\/strong\u003e Heats from ambient +5°C to 150°C, covering every common incubation protocol from gentle enzyme reactions at 37°C to sample denaturation at 95°C and beyond.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eDual LED Display:\u003c\/strong\u003e Simultaneously shows setpoint and actual temperature so you can confirm thermal equilibrium before loading samples — no guesswork, no separate thermometer needed.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eInterchangeable Block System:\u003c\/strong\u003e Blocks lift out and swap in seconds. Purchase additional blocks for 50 mL tubes, 6–15 mL tubes, or mixed configurations to adapt this one unit to every tube size in your lab.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eUniversal Power Supply:\u003c\/strong\u003e Ships with a 90–240 VAC adapter, making the unit operational on any mains voltage worldwide without an external transformer.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eUSA Designed and Assembled:\u003c\/strong\u003e Engineered and built in Atlanta, Georgia. Solid metal housing with insulated body and block-lifting handle ensures years of daily use in demanding lab environments.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDBL-40PL-02DP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLW Scientific\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Dry Bath Incubator\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Blocks Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo 20-place blocks for 1–2 mL microcentrifuge tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Tube Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 tubes (1–2 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlock Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient +5°C to 150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital PID Microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLED (setpoint and actual temperature)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable °F or °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDurable Metal with Insulated Body\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuction Cup (anti-slip)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90–240 VAC with included adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 lbs (2.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA (Atlanta, Georgia)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003ePCR preparation — pre-heating microcentrifuge tubes of master mix and template DNA to 95°C denaturation temperature before loading into the thermal cycler\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eRestriction enzyme digestion — maintaining 37°C incubation for genomic or plasmid DNA restriction reactions in 1.5 mL tubes\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eCell lysis and protein denaturation — heating samples to 70–100°C for SDS-PAGE sample preparation or bacterial cell lysis\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eSerum and reagent thawing — gentle warming of frozen aliquots at 37°C without the contamination risk of a water bath\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eELISA and immunoassay incubation — holding microtubes at a stable 37°C for antibody-antigen binding reactions requiring extended incubation times\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat tube sizes fit the DBL-40PL-02DP dry bath incubator?\u003c\/strong\u003e\u003cbr\u003eThis unit ships with two 20-place heat blocks designed for standard 1–2 mL microcentrifuge tubes. You can purchase separate interchangeable blocks to accommodate 6–15 mL tubes (SKU: DBP-12PL-1577), 50 mL tubes (SKU: DBP-04PL-5077), or 0.5–2 mL tubes in a 20-place configuration (SKU: DBP-20PL-0277).\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHow accurate is the temperature control on this dry bath?\u003c\/strong\u003e\u003cbr\u003eThe digital PID microprocessor provides precise temperature regulation with minimal overshoot. The LED display shows both the setpoint and actual real-time temperature, allowing you to verify that the unit has reached thermal equilibrium before loading your samples.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eCan I use this dry bath incubator with international power outlets?\u003c\/strong\u003e\u003cbr\u003eYes. The included power adapter operates on 90–240 VAC, making it compatible with mains voltage in North America, Europe, Asia, and other regions without an external step-down or step-up transformer.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIs this dry bath manufactured in the USA?\u003c\/strong\u003e\u003cbr\u003eYes. LW Scientific designs, engineers, and assembles this unit in Atlanta, Georgia, USA. The company provides direct technical support from their US-based team.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHow does a dry bath differ from a water bath for tube incubation?\u003c\/strong\u003e\u003cbr\u003eA dry bath uses solid aluminum blocks instead of heated water, eliminating the risk of water contamination reaching tube caps, removing the need for weekly water changes and biocide treatment, and providing faster temperature recovery when cold samples are loaded. Dry baths also have a smaller benchtop footprint than most water baths.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLW Scientific instruments are designed, engineered, and assembled in Atlanta, Georgia under rigorous quality standards. Each dry bath incubator undergoes functional testing before shipment to ensure accurate temperature control and reliable performance. LW Scientific provides direct technical support and warranty service from their US-based team.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eAcademic and Institutional Pricing\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLabSupplies.com offers tiered quantity pricing for academic and research institutions. As an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"LW Scientific","offers":[{"title":"Default Title","offer_id":48080286679272,"sku":"DBL-40PL-02DP","price":966.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/download.png?v=1771943465","url":"https:\/\/labsupplies.com\/products\/lw-scientific-dry-bath-incubator-2ml","provider":"LabSupplies.com","version":"1.0","type":"link"}