{"product_id":"heathrow-clinical-centrifuge","title":"Heathrow Scientific Clinical Centrifuge - 120775 Series | IVDR Class A, 6,000 rpm, 8-Program Memory","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eClinical labs, veterinary offices, hospital blood banks, and diagnostic centers share a common centrifuge requirement: reliable, programmable performance with built-in safety features — and a price point that doesn't require a capital equipment budget. The Heathrow Scientific Clinical Centrifuge delivers 500–6,000 rpm adjustable speed, IVDR Class A designation, and programmable memory for up to 8 protocols, in a compact benchtop footprint engineered for daily clinical workloads. This is not a research centrifuge repurposed for clinical use — it was designed specifically for clinical chemistry, blood collection prep, immunology, and pathology from the ground up.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe digitally controlled brushless motor requires zero motor maintenance and provides precise, repeatable speed control across every run. Rapid acceleration and gentle electronic braking (deceleration time under 60 seconds) protect sensitive clinical samples from damage during the stop phase.\u003c\/p\u003e\n\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIVDR Class A Designation:\u003c\/strong\u003e Certified under EU In Vitro Diagnostic Regulation 2017\/746 (Class A, Rule 5a) — meeting the regulatory requirements for use in clinical in-vitro diagnostic workflows across EU member states and aligned markets.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e8-Program Memory:\u003c\/strong\u003e Store up to 8 centrifugation protocols with speed (RPM or RCF) and time settings — eliminating manual re-entry for recurring protocols and reducing the risk of operator error in multi-protocol clinical environments.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e500–6,000 rpm Adjustable Speed (RPM or RCF):\u003c\/strong\u003e Set centrifugation speed in RPM for reproducibility or RCF for sample-specific g-force requirements — both are displayed on the backlit digital panel for at-a-glance verification.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eGentle Electronic Braking (\u0026lt;60 sec deceleration):\u003c\/strong\u003e Controlled deceleration under 60 seconds protects sample integrity — critical for serum\/plasma separation, blood banking, and immunology assays where pellet disturbance during braking compromises results.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eClear Lid with Viewing Porthole:\u003c\/strong\u003e Monitor rotor movement through the transparent lid without opening the centrifuge. Enables non-contact speed verification via tachometer and provides visual safety confirmation during operation.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eManual Lid Override for Power Failure:\u003c\/strong\u003e Access samples even during power outages — the manual lid unlock prevents sample loss in the event of unexpected power interruption, a critical feature for clinical environments where sample integrity cannot be compromised.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120775 (Blue\/Grey), 120776 (Purple\/Grey)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeathrow Scientific\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABS \/ Polycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-Place rotor\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeed Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500–6,000 rpm (RPM or RCF selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax RCF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,668 x g (with typical 15 mL tube)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Liquid Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mL (15 mL tube rotor, 8 positions)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgram Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 8 programs\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun Time Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 seconds – 60 minutes or continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 × 11.5 × 5.8 in (36.6 × 29.3 × 14.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.28–16 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240VAC, 50\/60Hz, 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12VDC, 12.5A, 150W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, IVDR (Class A, Rule 5a)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSerum \u0026amp; Plasma Separation:\u003c\/strong\u003e Program blood collection prep protocols — spin at defined RCF and time settings to achieve clean serum\/plasma separation reproducibly across every run, every shift.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eClinical Microbiology \u0026amp; Immunology:\u003c\/strong\u003e Pellet bacteria, cells, and immune complexes for culture, identification, and assay preparation in clinical microbiology and immunology workflows.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eVeterinary \u0026amp; Point-of-Care Clinics:\u003c\/strong\u003e The compact benchtop footprint and portable design make this unit practical for veterinary offices, urgent care centers, and satellite clinical labs where space is constrained and flexibility is required.\u003c\/p\u003e\u003c\/li\u003e\n  \u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eBlood Banking \u0026amp; Pathology:\u003c\/strong\u003e Meets the centrifugation requirements for blood banking preparation and pathology sample processing, with programmable protocols that reduce variability across technicians and shifts.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat does IVDR Class A designation mean for the Clinical Centrifuge?\u003c\/strong\u003e\u003cbr\u003eIVDR (EU 2017\/746) Class A, Rule 5a certification means this centrifuge meets the European Union's regulatory requirements for in-vitro diagnostic instruments. This designation is relevant for labs subject to EU IVD compliance requirements and provides documentation for quality management audits.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is the difference between 120775 (Blue\/Grey) and 120776 (Purple\/Grey)?\u003c\/strong\u003e\u003cbr\u003eBoth are functionally identical — same speed range, same IVDR certification, same 8-program memory, and same 5-year warranty. The only difference is the accent color of the unit housing. Color choice is purely aesthetic.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eCan the Clinical Centrifuge run continuously without a time limit?\u003c\/strong\u003e\u003cbr\u003eYes. In addition to the 30-second to 60-minute timer settings, the unit supports a continuous run mode for applications that require extended centrifugation without automatic shut-off.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat tube sizes does the Clinical Centrifuge accommodate?\u003c\/strong\u003e\u003cbr\u003eThe standard rotor is an 8-place configuration designed for 15 mL conical tubes. Tube adapters for the Clinical Centrifuge (SKU 120783) are available separately to accommodate additional tube formats.\u003c\/p\u003e\n\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe Heathrow Scientific Clinical Centrifuge is CE, UKCA, and IVDR certified, meeting regulatory standards for clinical in-vitro diagnostic use. Manufactured under rigorous quality controls with a 5-year warranty and a digitally controlled brushless motor requiring no scheduled motor maintenance.\u003c\/p\u003e\n\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eAcademic and Institutional Pricing\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLabSupplies.com offers tiered quantity pricing for academic and research institutions. As an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"Heathrow Scientific","offers":[{"title":"Blue\/Grey","offer_id":48073589063912,"sku":"120775","price":1163.0,"currency_code":"USD","in_stock":true},{"title":"Purple\/Grey","offer_id":48073589096680,"sku":"'120776","price":1046.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/unnamed_74218027-de1e-45af-ad1f-e573ded65681.jpg?v=1771686577","url":"https:\/\/labsupplies.com\/products\/heathrow-clinical-centrifuge","provider":"LabSupplies.com","version":"1.0","type":"link"}