{"product_id":"global-industrial-emergency-eyewash-wall-mounted-708381","title":"Global Industrial Emergency Eyewash Station, Wall Mounted, ANSI Z358.1-2014 (708381)","description":"\u003ch2\u003eGlobal Industrial Wall-Mounted Emergency Eyewash Features\u003c\/h2\u003e\n\n\u003cp\u003eDesigned for chemical hazard locations adjacent to structural walls, the Global Industrial 708381 is a wall-mounted \u003cstrong\u003eemergency eyewash station\u003c\/strong\u003e compliant with ANSI Z358.1-2014. Schedule 40 galvanized steel pipe with safety yellow covers delivers flushing fluid at 5.15 gallons per minute through dual spray heads with flip-top dust covers into an 11.5-inch ABS plastic bowl. Push-handle activation opens a stay-open ball valve for hands-free operation, exceeding the ANSI minimum of 0.4 GPM to both eyes for 15 minutes.\u003c\/p\u003e\n\n\u003cp\u003eWall mounting eliminates the pedestal floor footprint, keeping aisles clear while placing the eyewash within 10 seconds of wall-adjacent hazards. At $305 it is $44 less than the equivalent pedestal model (708382) with identical ANSI Z358.1-2014 compliance and construction. Each unit includes an ANSI compliant identification sign and ships with factory-tested valves and spray heads. Backed by a 1-year limited warranty from Global Industrial.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #ddd;margin:1em 0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px 12px;background:#f5f5f5;text-align:left;font-weight:600\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px 12px;background:#f5f5f5;text-align:left;font-weight:600\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eGlobal Industrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eItem #\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003e708381\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eWall mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003ePipe \u0026amp; Fittings\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eSchedule 40 galvanized steel with safety yellow polyethylene covers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eBowl\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003e11.5\" ABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eSpray Heads\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eDual, with flip-top covers to protect from airborne contaminants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eActivation\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003ePush-handle — stay-open ball valve for hands-free operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eFlow Rate\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003e5.15 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eWater Connection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eInlet and outlet tee — separate inflow and waste outflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eColor\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eSafety yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eCompliance\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eANSI Z358.1-2014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eIncludes\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eANSI compliant identification sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eQuality Assurance\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eValves and spray heads factory-tested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003e1-year limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\n\u003cp\u003eTo provide ANSI Z358.1-2014 compliant eyewash coverage at wall-adjacent chemical hazard locations, the Global Industrial 708381 is installed at laboratory fume hoods and benches along room perimeters, production lines against facility walls, chemical storage and dispensing areas at wall-adjacent locations, battery maintenance areas, and any workspace where the hazard is within 10 seconds of a structural wall to which the eyewash can be plumbed and anchored.\u003c\/p\u003e\n\n\u003ch2\u003eWall Mount vs. Pedestal Mount Eyewash\u003c\/h2\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;border:1px solid #ddd;margin:1em 0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px 12px;background:#f5f5f5;text-align:left;font-weight:600\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px 12px;background:#f5f5f5;text-align:left;font-weight:600\"\u003eWall Mount (708381)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:8px 12px;background:#f5f5f5;text-align:left;font-weight:600\"\u003ePedestal Mount (708382)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eWall — requires structural wall\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003ePedestal — freestanding floor mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003ePlacement\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003ePerimeter walls, along production lines\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eOpen floor areas, mid-workspace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eInstallation\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eWall anchoring + plumbing connection required\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003ePlumb to floor; no wall anchoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eProfile\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eLower profile — does not project into aisle\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eColumn projects above floor level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eAccessibility\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eFrontal approach from work area\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003e360° approach from any direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eFloor Space\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eNo floor footprint beyond wall connection\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003ePedestal base occupies floor area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003ePrice\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003e$305 — $44 less than pedestal\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003e$349\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eCompliance\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eANSI Z358.1-2014\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px 12px\"\u003eANSI Z358.1-2014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eAcademic and Institutional Pricing\u003c\/h2\u003e\n\n\u003cp\u003eLabSupplies.com offers tiered quantity pricing for academic and research institutions. As an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eWhen is a wall-mounted eyewash the right choice over a pedestal unit?\u003c\/h3\u003e\n\u003cp\u003eWall mounting suits locations where the chemical hazard is adjacent to a structural wall — allowing the worker to reach the eyewash within the required 10-second travel distance without needing a freestanding unit in open floor space. Production lines and workbenches against walls, laboratory fume hoods along room perimeters, and wall-adjacent dispensing areas are well-suited to wall mounting. Wall mounting eliminates the pedestal floor footprint, keeping aisles clear. Pedestal mount (708382) is right when the hazard is in an open area away from any structural wall.\u003c\/p\u003e\n\u003ch3\u003eWhat wall construction is required for the 708381?\u003c\/h3\u003e\n\u003cp\u003eThe 708381 requires a structural wall capable of supporting the eyewash unit, water supply pipe, and operational activation loads. Stud-framed drywall with proper fasteners into studs is typically adequate for light commercial construction; concrete block or steel-framed industrial walls require appropriate anchors. Water supply access behind or through the mounting wall is required. A licensed plumber should complete the water connection to ensure compliance with local plumbing codes.\u003c\/p\u003e\n\u003ch3\u003eDoes the wall-mounted 708381 meet the same ANSI Z358.1-2014 requirements as the pedestal 708382?\u003c\/h3\u003e\n\u003cp\u003eYes. Both share identical ANSI Z358.1-2014 compliance, Schedule 40 galvanized pipe construction, 11.5-inch ABS plastic bowl, dual flip-top spray heads, push-handle stay-open valve, and 5.15 GPM flow rate. Mounting type does not change ANSI performance requirements — both must be installed with nozzles between 33 and 45 inches from the floor, within 10 seconds of the hazard, with unobstructed access. Choosing wall vs. pedestal is a placement and installation decision, not a compliance distinction.\u003c\/p\u003e\n\u003ch3\u003eHow often should the 708381 wall-mounted eyewash be tested and inspected?\u003c\/h3\u003e\n\u003cp\u003eANSI Z358.1-2014 recommends weekly activation to flush sediment and confirm both spray heads flow. A brief weekly test takes under one minute and verifies the water supply is open and operational. Annual inspection by a competent person checks flow rate, spray pattern, nozzle condition, and ANSI compliance. Monthly visual inspection of flip-top covers and the identification sign is also recommended. The inlet and outlet tee allows connection to a drain for controlled waste water disposal during weekly testing.\u003c\/p\u003e\n\n\u003ch2\u003eGlobal Industrial Emergency Eyewash and Safety Shower Line\u003c\/h2\u003e\n\n\u003cp\u003eFor open-floor locations without a wall within 10 seconds of the hazard, the Global Industrial pedestal eyewash (708382) provides identical ANSI performance. For locations without plumbing access, the portable 9-gallon gravity-fed eyewash (708606) provides ANSI Z358.1-2014 compliant coverage. Where both body and eye exposure risk exist, the emergency combination shower with eyewash (708383) provides full decontamination capability. All four models are available at LabSupplies.com.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\/\",\n  \"@type\": \"Product\",\n  \"name\": \"Global Industrial Emergency Eyewash, Wall Mounted, ANSI, 708381\",\n  \"description\": \"Global Industrial 708381 emergency eyewash station, wall mounted. ANSI Z358.1-2014 compliant. Schedule 40 galvanized steel, 11.5\\\" ABS bowl, 5.15 GPM, push-handle hands-free activation.\",\n  \"sku\": \"708381\",\n  \"mpn\": \"708381\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Global Industrial\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Global Industrial\",\n    \"url\": \"https:\/\/www.globalindustrial.com\"\n  },\n  \"image\": \"https:\/\/images.globalindustrial.com\/images\/enlarge\/708381.webp?t=1777419142846\",\n  \"offers\": {\n    \"@type\": \"Offer\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/global-industrial-emergency-eyewash-wall-mounted-708381\",\n    \"priceCurrency\": \"USD\",\n    \"price\": \"305.00\",\n    \"availability\": \"https:\/\/schema.org\/InStock\",\n    \"itemCondition\": \"https:\/\/schema.org\/NewCondition\",\n    \"seller\": {\n      \"@type\": \"Organization\",\n      \"name\": \"LabSupplies.com\"\n    },\n    \"warranty\": \"1-year limited warranty\"\n  },\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Wall mounted\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Compliance\",\n      \"value\": \"ANSI Z358.1-2014\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flow Rate\",\n      \"value\": \"5.15 GPM\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Bowl\",\n      \"value\": \"11.5 inch ABS plastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Pipe\",\n      \"value\": \"Schedule 40 galvanized steel\"\n    }\n  ],\n  \"isRelatedTo\": [\n    {\n      \"@type\": \"Product\",\n      \"name\": \"Global Industrial Emergency Eyewash, Pedestal Mounted, 708382\",\n      \"sku\": \"708382\"\n    },\n    {\n      \"@type\": \"Product\",\n      \"name\": \"Global Industrial Emergency Combination Shower with Eyewash, 708383\",\n      \"sku\": \"708383\"\n    },\n    {\n      \"@type\": \"Product\",\n      \"name\": \"Global Industrial Portable Eyewash, 9-Gallon Gravity Fed, 708606\",\n      \"sku\": \"708606\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"When is a wall-mounted eyewash the right choice over a pedestal unit?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Wall mounting suits locations where the chemical hazard is adjacent to a structural wall \\u2014 allowing the worker to reach the eyewash within the required 10-second travel distance without needing a freestanding unit in open floor space. Production lines and workbenches against walls, laboratory fume hoods along room perimeters, and wall-adjacent dispensing areas are well-suited to wall mounting. Wall mounting eliminates the pedestal floor footprint, keeping aisles clear. Pedestal mount (708382) is right when the hazard is in an open area away from any structural wall.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What wall construction is required for the 708381?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The 708381 requires a structural wall capable of supporting the eyewash unit, water supply pipe, and operational activation loads. Stud-framed drywall with proper fasteners into studs is typically adequate for light commercial construction; concrete block or steel-framed industrial walls require appropriate anchors. Water supply access behind or through the mounting wall is required. A licensed plumber should complete the water connection to ensure compliance with local plumbing codes.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the wall-mounted 708381 meet the same ANSI Z358.1-2014 requirements as the pedestal 708382?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. Both share identical ANSI Z358.1-2014 compliance, Schedule 40 galvanized pipe construction, 11.5-inch ABS plastic bowl, dual flip-top spray heads, push-handle stay-open valve, and 5.15 GPM flow rate. Mounting type does not change ANSI performance requirements \\u2014 both must be installed with nozzles between 33 and 45 inches from the floor, within 10 seconds of the hazard, with unobstructed access. Choosing wall vs. pedestal is a placement and installation decision, not a compliance distinction.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How often should the 708381 wall-mounted eyewash be tested and inspected?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"ANSI Z358.1-2014 recommends weekly activation to flush sediment and confirm both spray heads flow. A brief weekly test takes under one minute and verifies the water supply is open and operational. Annual inspection by a competent person checks flow rate, spray pattern, nozzle condition, and ANSI compliance. Monthly visual inspection of flip-top covers and the identification sign is also recommended. The inlet and outlet tee allows connection to a drain for controlled waste water disposal during weekly testing.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\/\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"Safety Equipment\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/safety-equipment\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"Global Industrial Emergency Eyewash, Wall Mounted, ANSI, 708381\",\n      \"item\": \"https:\/\/labsupplies.com\/products\/global-industrial-emergency-eyewash-wall-mounted-708381\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Organization\",\n  \"name\": \"Global Industrial\",\n  \"url\": \"https:\/\/www.globalindustrial.com\",\n  \"description\": \"Industrial equipment and supply distributor with over one million products.\"\n}\n\u003c\/script\u003e","brand":"Global Industrial","offers":[{"title":"Default Title","offer_id":48490596663528,"sku":"708381","price":305.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/708381.webp?v=1777949881","url":"https:\/\/labsupplies.com\/products\/global-industrial-emergency-eyewash-wall-mounted-708381","provider":"LabSupplies.com","version":"1.0","type":"link"}