{"product_id":"accuris-smartdrop-xf-nano-spectrophotometer-and-fluorometer-ns1020","title":"Accuris SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020 | 200–800 nm, dsDNA 0.5 pg\/µL to 15,000 ng\/µL","description":"\u003cp\u003eThe SmartDrop XF NS1020 pairs a full-spectrum 200–800 nm absorbance spectrophotometer with a blue-excitation fluorometer for low-concentration DNA work. Path lengths of 0.05, 0.2 and 1.0 mm extend the absorbance range to 0.04–300 A (10 mm equivalent), reading dsDNA up to 15,000 ng\/µL and BSA up to 360 mg\/mL from 0.5–2.0 µL samples. The fluorometer excites at 460 ± 20 nm, collects 525–570 nm emission and detects dsDNA down to 0.5 pg\/µL. A 7-inch touch screen runs the instrument without a PC.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAbsorbance 200–800 nm in 1 nm steps, xenon flash lamp\u003c\/li\u003e\n\u003cli\u003ePath lengths 0.05, 0.2 and 1.0 mm; range 0.04–300 A\u003c\/li\u003e\n\u003cli\u003edsDNA up to 15,000 ng\/µL and BSA up to 360 mg\/mL by absorbance\u003c\/li\u003e\n\u003cli\u003eFluorometer: 460 ± 20 nm excitation, 525–570 nm emission\u003c\/li\u003e\n\u003cli\u003eFluorescence sensitivity to 0.5 pg\/µL dsDNA\u003c\/li\u003e\n\u003cli\u003e7-inch touch screen, USB export, results in under 6 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eAccuris\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog number\u003c\/th\u003e\n\u003ctd\u003eNS1020 \/ NS1020-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e7 in touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Volume\u003c\/th\u003e\n\u003ctd\u003e0.5–2.0 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePath Length\u003c\/th\u003e\n\u003ctd\u003e0.05 mm, 0.2 mm, 1.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLight Source\u003c\/th\u003e\n\u003ctd\u003eXenon flash lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetector\u003c\/th\u003e\n\u003ctd\u003e2,048-element linear silicon CCD array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWavelength Range\u003c\/th\u003e\n\u003ctd\u003e200–800 nm (1 nm steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbance Range\u003c\/th\u003e\n\u003ctd\u003e0.04–300 A (10 mm equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLower Limit of Detection\u003c\/th\u003e\n\u003ctd\u003edsDNA: 2 ng\/µL; BSA: 0.1 mg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUpper Limit of Detection\u003c\/th\u003e\n\u003ctd\u003edsDNA: 15,000 ng\/µL; BSA: 360 mg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluorescence Excitation \/ Emission\u003c\/th\u003e\n\u003ctd\u003e460 ± 20 nm \/ 525–570 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluorescence Sensitivity\u003c\/th\u003e\n\u003ctd\u003edsDNA: 0.5 pg\/µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection Time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e24 V DC, 2 A; 25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (W × D × H)\u003c\/th\u003e\n\u003ctd\u003e8.2 × 12.6 × 7.3 in (20.8 × 32.0 × 18.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e7.9 lb (3.6 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eOrdering information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalog number\u003c\/th\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNS1020\u003c\/td\u003e\n\u003ctd\u003e115V, US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNS1020-E\u003c\/td\u003e\n\u003ctd\u003e230V, European plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eQuestions about the SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020\u003c\/h2\u003e\u003ch3\u003eWhat sample volume and detection range does the SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020 work with?\u003c\/h3\u003e\u003cp\u003eThe SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020 uses 0.5–2.0 µL of sample, with a lower limit of detection of dsDNA: 2 ng\/µL; BSA: 0.1 mg\/mL and an absorbance range of 0.04–300 A (10 mm equivalent).\u003c\/p\u003e\u003ch3\u003eIs the SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020 available with a European plug?\u003c\/h3\u003e\u003cp\u003eYes. NS1020-E is the European-plug version of NS1020: NS1020 is 115V with a US plug and NS1020-E is 230V with a European plug.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1020-Operation-Manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstruction manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1000-Series-Literature.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Product\",\"@id\":\"https:\/\/labsupplies.com\/products\/accuris-smartdrop-xf-nano-spectrophotometer-and-fluorometer-ns1020#product\",\"brand\":{\"@type\":\"Brand\",\"name\":\"Accuris\"},\"manufacturer\":{\"@type\":\"Organization\",\"name\":\"Accuris\"}},{\"@type\":\"Offer\",\"@id\":\"https:\/\/labsupplies.com\/products\/accuris-smartdrop-xf-nano-spectrophotometer-and-fluorometer-ns1020?variant=67828548075752#offer\",\"mpn\":\"NS1020\",\"sku\":\"NS1020\"},{\"@type\":\"Offer\",\"@id\":\"https:\/\/labsupplies.com\/products\/accuris-smartdrop-xf-nano-spectrophotometer-and-fluorometer-ns1020?variant=67828548108520#offer\",\"mpn\":\"NS1020-E\",\"sku\":\"NS1020-E\"},{\"@type\":\"FAQPage\",\"@id\":\"https:\/\/labsupplies.com\/products\/accuris-smartdrop-xf-nano-spectrophotometer-and-fluorometer-ns1020#faq\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What sample volume and detection range does the SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020 work with?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020 uses 0.5–2.0 µL of sample, with a lower limit of detection of dsDNA: 2 ng\/µL; BSA: 0.1 mg\/mL and an absorbance range of 0.04–300 A (10 mm equivalent).\"}},{\"@type\":\"Question\",\"name\":\"Is the SmartDrop XF Nano Spectrophotometer and Fluorometer NS1020 available with a European plug?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. NS1020-E is the European-plug version of NS1020: NS1020 is 115V with a US plug and NS1020-E is 230V with a European plug.\"}}]}]}\u003c\/script\u003e","brand":"Accuris","offers":[{"title":"115V, US plug","offer_id":67828548075752,"sku":"NS1020","price":13405.21,"currency_code":"USD","in_stock":true},{"title":"230V, European plug","offer_id":67828548108520,"sku":"NS1020-E","price":13405.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/NS1020_20SmartDrop_E2_84_A2_20XF_20Front_20View.jpg?v=1790994939","url":"https:\/\/labsupplies.com\/products\/accuris-smartdrop-xf-nano-spectrophotometer-and-fluorometer-ns1020","provider":"LabSupplies.com","version":"1.0","type":"link"}