{"product_id":"accuris-smart-q-800-8-sample-fluorometer-f1008","title":"Accuris Smart-Q 800 8-Sample Fluorometer F1008 | 0.2 mL Tubes and 8-Tube Strips, 460\/625 nm Excitation","description":"\u003cp\u003eThe Smart-Q 800 F1008 reads up to 8 samples at once, using 0.2 mL assay tubes either singly or as 8-tube strips. It quantifies DNA, RNA and protein through dye-based fluorescence assays from Accuris or other kit suppliers. Excitation comes from blue and red LEDs at 460 ± 20 nm and 625 ± 20 nm, with emission collected at 525–570 nm and 670–725 nm across a dynamic range of 4 orders of magnitude. Setup runs on a 7.0-inch touch screen with built-in reagent calculators.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMeasures 8 samples per run in 0.2 mL tubes or 8-tube strips\u003c\/li\u003e\n\u003cli\u003eDual LED excitation: blue 460 ± 20 nm, red 625 ± 20 nm\u003c\/li\u003e\n\u003cli\u003eGreen 525–570 nm and red 670–725 nm emission detection\u003c\/li\u003e\n\u003cli\u003ePhotodiode detectors, 4 orders of magnitude dynamic range\u003c\/li\u003e\n\u003cli\u003eQuantitation down to 0.1 pg\/µL dsDNA\u003c\/li\u003e\n\u003cli\u003e16.1 × 28.7 × 7.6 cm, 2.0 kg (4.4 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eAccuris\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog number\u003c\/th\u003e\n\u003ctd\u003eF1008 \/ F1008-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacity\u003c\/th\u003e\n\u003ctd\u003e8 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e7.0 in color touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDynamic Range\u003c\/th\u003e\n\u003ctd\u003e4 orders of magnitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLight Source\u003c\/th\u003e\n\u003ctd\u003eBlue and red LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExcitation Wavelengths\u003c\/th\u003e\n\u003ctd\u003eBlue: 460 ± 20 nm; Red: 625 ± 20 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmission Wavelengths\u003c\/th\u003e\n\u003ctd\u003eGreen: 525–570 nm; Red: 670–725 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetector\u003c\/th\u003e\n\u003ctd\u003ePhotodiodes (300–1,000 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConsumables\u003c\/th\u003e\n\u003ctd\u003e0.2 mL assay tubes (single and 8-tube strip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRead Time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData Export\u003c\/th\u003e\n\u003ctd\u003eUSB flash drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V DC, 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (W × D × H)\u003c\/th\u003e\n\u003ctd\u003e6.3 × 11.3 × 3.0 in (16.1 × 28.7 × 7.6 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e4.4 lb (2.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eOrdering information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalog number\u003c\/th\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eF1008\u003c\/td\u003e\n\u003ctd\u003e115V, US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF1008-E\u003c\/td\u003e\n\u003ctd\u003e230V, European plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/02\/F1008-User-Manual-V1.1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstruction manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2025\/11\/F1001_F1008-Literature-2025.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Product\",\"@id\":\"https:\/\/labsupplies.com\/products\/accuris-smart-q-800-8-sample-fluorometer-f1008#product\",\"brand\":{\"@type\":\"Brand\",\"name\":\"Accuris\"},\"manufacturer\":{\"@type\":\"Organization\",\"name\":\"Accuris\"}},{\"@type\":\"Offer\",\"@id\":\"https:\/\/labsupplies.com\/products\/accuris-smart-q-800-8-sample-fluorometer-f1008?variant=67828548305128#offer\",\"mpn\":\"F1008\",\"sku\":\"F1008\"},{\"@type\":\"Offer\",\"@id\":\"https:\/\/labsupplies.com\/products\/accuris-smart-q-800-8-sample-fluorometer-f1008?variant=67828548337896#offer\",\"mpn\":\"F1008-E\",\"sku\":\"F1008-E\"}]}\u003c\/script\u003e","brand":"Accuris","offers":[{"title":"115V, US plug","offer_id":67828548305128,"sku":"F1008","price":6868.34,"currency_code":"USD","in_stock":true},{"title":"230V, European plug","offer_id":67828548337896,"sku":"F1008-E","price":6868.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/F1001_F1008_20Side_20View_202_206x6_20in.jpg?v=1790994966","url":"https:\/\/labsupplies.com\/products\/accuris-smart-q-800-8-sample-fluorometer-f1008","provider":"LabSupplies.com","version":"1.0","type":"link"}