{"product_id":"accuris-smart-q-100-fluorometer-f1001","title":"Accuris Smart-Q 100 Fluorometer F1001 | Single Sample, Blue 460 nm \u0026 Red 625 nm Excitation, 0.5 mL Tubes","description":"\u003cp\u003eThe Smart-Q 100 F1001 is a single-sample fluorometer for quantifying DNA, RNA and protein with dye-based assays, which bind selectively to their target and give higher specificity than UV absorbance. Blue (460 ± 20 nm) and red (625 ± 20 nm) LED excitation channels feed photodiode detectors reading green 525–570 nm and red 670–725 nm emission. It measures 0.5 mL assay tubes over 5 orders of magnitude, down to 0.1 pg\/µL dsDNA, and returns results in under 6 seconds on a 7.0-inch touch screen.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eReads one 0.5 mL assay tube at a time\u003c\/li\u003e\n\u003cli\u003eBlue 460 nm and red 625 nm LED excitation (± 20 nm)\u003c\/li\u003e\n\u003cli\u003eEmission channels 525–570 nm and 670–725 nm\u003c\/li\u003e\n\u003cli\u003eDynamic range of 5 orders of magnitude; dsDNA to 0.1 pg\/µL\u003c\/li\u003e\n\u003cli\u003eBuilt-in reagent calculators and preprogrammed protocols\u003c\/li\u003e\n\u003cli\u003e16.1 × 28.7 × 6.1 cm, 1.6 kg; USB flash drive export\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eAccuris\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog number\u003c\/th\u003e\n\u003ctd\u003eF1001 \/ F1001-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacity\u003c\/th\u003e\n\u003ctd\u003eSingle sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e7.0 in color touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDynamic Range\u003c\/th\u003e\n\u003ctd\u003e5 orders of magnitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLight Source\u003c\/th\u003e\n\u003ctd\u003eBlue and red LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExcitation Wavelengths\u003c\/th\u003e\n\u003ctd\u003eBlue: 460 ± 20 nm; Red: 625 ± 20 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmission Wavelengths\u003c\/th\u003e\n\u003ctd\u003eGreen: 525–570 nm; Red: 670–725 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetector\u003c\/th\u003e\n\u003ctd\u003ePhotodiodes (300–1,000 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConsumables\u003c\/th\u003e\n\u003ctd\u003e0.5 mL assay tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRead Time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData Export\u003c\/th\u003e\n\u003ctd\u003eUSB flash drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e24 V DC, 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (W × D × H)\u003c\/th\u003e\n\u003ctd\u003e6.34 × 11.30 × 2.40 in (16.1 × 28.7 × 6.1 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e3.5 lb (1.6 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eOrdering information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalog number\u003c\/th\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eF1001\u003c\/td\u003e\n\u003ctd\u003e115V, US plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF1001-E\u003c\/td\u003e\n\u003ctd\u003e230V, European plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/01\/F1001-User-Manual-V1.1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstruction manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2025\/11\/F1001_F1008-Literature-2025.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Product\",\"@id\":\"https:\/\/labsupplies.com\/products\/accuris-smart-q-100-fluorometer-f1001#product\",\"brand\":{\"@type\":\"Brand\",\"name\":\"Accuris\"},\"manufacturer\":{\"@type\":\"Organization\",\"name\":\"Accuris\"}},{\"@type\":\"Offer\",\"@id\":\"https:\/\/labsupplies.com\/products\/accuris-smart-q-100-fluorometer-f1001?variant=67828548239592#offer\",\"mpn\":\"F1001\",\"sku\":\"F1001\"},{\"@type\":\"Offer\",\"@id\":\"https:\/\/labsupplies.com\/products\/accuris-smart-q-100-fluorometer-f1001?variant=67828548272360#offer\",\"mpn\":\"F1001-E\",\"sku\":\"F1001-E\"}]}\u003c\/script\u003e","brand":"Accuris","offers":[{"title":"115V, US plug","offer_id":67828548239592,"sku":"F1001","price":4165.59,"currency_code":"USD","in_stock":true},{"title":"230V, European plug","offer_id":67828548272360,"sku":"F1001-E","price":4165.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/F1001_F1008-Side-View-2-600x600px.jpg?v=1790994957","url":"https:\/\/labsupplies.com\/products\/accuris-smart-q-100-fluorometer-f1001","provider":"LabSupplies.com","version":"1.0","type":"link"}