{"product_id":"accuris-high-sensitivity-dna-quantification-kit-100-assays","title":"Accuris High Sensitivity dsDNA Quantification Kit | Fluorometer Assay 100 Assays NS1020-HS-100","description":"\u003ch2\u003eAccuris High Sensitivity dsDNA Quantification Kit Features\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAccuris High Sensitivity dsDNA Quantification Kit (NS1020-HS-100)\u003c\/strong\u003e delivers selective fluorescent quantification of double-stranded DNA across a 0.1 to 120 ng detection range. Engineered by Accuris, a division of Benchmark Scientific, it resolves initial sample concentrations from 0.005 to 120 ng\/µl. Each kit supports 100 assays.\u003c\/p\u003e\n\u003cp\u003eSelectivity is the core advantage. Reagents bind dsDNA exclusively, so single-stranded DNA, RNA, protein, and free nucleotides do not skew results. Lab managers gain trustworthy low-concentration readings where absorbance methods fail, protecting downstream library prep and sequencing budgets.\u003c\/p\u003e\n\u003cp\u003eHandling is straightforward and bench-safe. Store all four components at 4°C, and protect the concentrated reagent from light. Included are the HS dsDNA reagent, dilution buffer, and two ready-to-use DNA standards, eliminating separate standard sourcing.\u003c\/p\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel #\u003c\/th\u003e\n\u003cth\u003eMPN #\u003c\/th\u003e\n\u003cth\u003eAssays\u003c\/th\u003e\n\u003cth\u003eFormat\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eGI-MODEL-PLACEHOLDER\u003c\/td\u003e\n\u003ctd\u003eNS1020-HS-100\u003c\/td\u003e\n\u003ctd\u003e100 Assays\u003c\/td\u003e\n\u003ctd\u003eReagent kit (4 components)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAccuris (division of Benchmark Scientific)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel #\u003c\/td\u003e\n\u003ctd\u003eGI-MODEL-PLACEHOLDER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPN #\u003c\/td\u003e\n\u003ctd\u003eNS1020-HS-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFluorescent dsDNA quantification kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 120 ng\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Concentration Range\u003c\/td\u003e\n\u003ctd\u003e0.005 to 120 ng\/µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Input Volume\u003c\/td\u003e\n\u003ctd\u003e1 µL to 20 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation \/ Emission\u003c\/td\u003e\n\u003ctd\u003e460 ± 20 nm (blue) \/ 525 to 570 nm (green)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eDouble-stranded DNA (dsDNA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Compatibility\u003c\/td\u003e\n\u003ctd\u003eQubit, SmartDrop XF, microplate readers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssays per Kit\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e4°C, reagent protected from light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eMolecular biology cores rely on this kit to validate DNA input before NGS library preparation, qPCR, and cloning. Accurate low-end quantification protects sequencing runs from under- or over-loaded templates, a frequent source of failed flow cells in university and core facility workflows.\u003c\/p\u003e\n\u003cp\u003eQC labs and forensic teams apply the assay when sample mass is limiting and absorbance ratios prove unreliable. Selective dsDNA detection supports genomic studies, biobanking, and AME-adjacent diagnostic preparation where precise nanogram-level confirmation is mandatory.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose LabSupplies.com?\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFactor\u003c\/th\u003e\n\u003cth\u003eLabSupplies.com\u003c\/th\u003e\n\u003cth\u003eTypical Competitor\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSourcing\u003c\/td\u003e\n\u003ctd\u003eAuthorized dealer, USA inventory\u003c\/td\u003e\n\u003ctd\u003eGray-market or drop-ship uncertainty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePricing\u003c\/td\u003e\n\u003ctd\u003eBelow retail pricing, volume discounts\u003c\/td\u003e\n\u003ctd\u003eList price, rigid tiers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcurement Support\u003c\/td\u003e\n\u003ctd\u003eTechnical sales for QC and academic labs\u003c\/td\u003e\n\u003ctd\u003eGeneric call-center routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAcademic and Institutional Pricing\u003c\/h2\u003e\n\u003cp\u003eLabSupplies.com offers tiered quantity pricing for academic and research institutions. As an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/02\/NS1020-HS-100-Product-Insert.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNS1020-HS-100 Product Insert (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/02\/NS1020-BRHS-Acuris-DNA-Quantification-Kits.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAccuris DNA Quantification Kits Line Card (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eIs NS1020-HS-100 compatible with the Qubit fluorometer?\u003c\/h3\u003e\n\u003cp\u003eYes. The kit is formulated for blue-excitation fluorometers including the Qubit, the Accuris SmartDrop XF, and standard microplate readers, using 460 nm excitation and green emission detection between 525 and 570 nm.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the High Sensitivity and Broad Range kits?\u003c\/h3\u003e\n\u003cp\u003eThe High Sensitivity kit (NS1020-HS-100) covers 0.1 to 120 ng for low-concentration samples. The Broad Range kit (NS1020-BR-100) covers 4 to 2,000 ng. Choose High Sensitivity when template mass is limiting.\u003c\/p\u003e\n\u003ch3\u003eWill RNA or protein in my sample affect the reading?\u003c\/h3\u003e\n\u003cp\u003eNo. The reagent is selective for double-stranded DNA, so ssDNA, RNA, protein, and free nucleotides do not contribute to the measured fluorescence, yielding accurate dsDNA-specific quantification.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\/\",\"@type\":\"Product\",\"name\":\"Accuris High Sensitivity dsDNA Quantification Kit, 100 Assays\",\"brand\":{\"@type\":\"Brand\",\"name\":\"Accuris\"},\"sku\":\"GI-MODEL-PLACEHOLDER\",\"mpn\":\"NS1020-HS-100\",\"image\":\"https:\/\/imagedelivery.net\/wgHagV-y9mRi7Go2OBhKVA\/www.labrepco.com\/2023\/04\/NS1020-BRHS-Acuris-DNA-Quantification-Kits.webp\/w=750,h=692\",\"offers\":{\"@type\":\"Offer\",\"priceCurrency\":\"USD\",\"price\":\"155.95\",\"availability\":\"https:\/\/schema.org\/InStock\",\"seller\":{\"@type\":\"Organization\",\"name\":\"LabSupplies.com\"}}}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\/\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Is NS1020-HS-100 compatible with the Qubit fluorometer?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The kit is formulated for blue-excitation fluorometers including the Qubit, the Accuris SmartDrop XF, and standard microplate readers, using 460 nm excitation and green emission detection between 525 and 570 nm.\"}},{\"@type\":\"Question\",\"name\":\"What is the difference between the High Sensitivity and Broad Range kits?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The High Sensitivity kit (NS1020-HS-100) covers 0.1 to 120 ng for low-concentration samples. The Broad Range kit (NS1020-BR-100) covers 4 to 2,000 ng. Choose High Sensitivity when template mass is limiting.\"}},{\"@type\":\"Question\",\"name\":\"Will RNA or protein in my sample affect the reading?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The reagent is selective for double-stranded DNA, so ssDNA, RNA, protein, and free nucleotides do not contribute to the measured fluorescence, yielding accurate dsDNA-specific quantification.\"}}]}\n\u003c\/script\u003e","brand":"Accuris","offers":[{"title":"100 Assays","offer_id":48629761442024,"sku":"NS1020-HS-100","price":155.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/w_750_h_692.jpg?v=1780931008","url":"https:\/\/labsupplies.com\/products\/accuris-high-sensitivity-dna-quantification-kit-100-assays","provider":"LabSupplies.com","version":"1.0","type":"link"}