{"title":"NXT Power","description":"\u003cp\u003e\u003cstrong\u003eNXT Power\u003c\/strong\u003e builds uninterruptible power supplies and power conditioners that protect sensitive lab and medical equipment. As an authorized dealer, we ship the Integrity Series from US inventory with direct manufacturer service and support. Filter by model and form factor below.\u003c\/p\u003e","products":[{"product_id":"nxt-power-integrity-pro-desktop-ups-250va-nptu250-gl-n","title":"NXT Power Integrity PRO Desktop UPS 250VA — Isolated Line-Interactive Power Conditioner (NPTU250-GL-N)","description":"\u003ch2\u003eNXT Power Integrity PRO Desktop UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity PRO Desktop UPS (NPTU250-GL-N)\u003c\/strong\u003e delivers 250 VA \/ 200 W of isolated, line-interactive backup power. It shields sensitive bench instruments, point-of-sale terminals, and back-office IT from spikes, sags, and outages. Inside the chassis, a low-impedance isolation transformer, surge diverter, and noise filter clean incoming power before disturbances reach the load.\u003c\/p\u003e\n\u003cp\u003eUnlike strip-style battery backups, this unit pairs galvanic isolation with true sine wave output for sensitive loads. NXT GROUND circuitry eliminates ground loops that trigger system lock-ups on networked benches and registers. A 24 VDC output rail powers compatible printers directly, removing the external adapter that clutters most counters.\u003c\/p\u003e\n\u003cp\u003eEvery Integrity PRO Desktop unit is listed to UL1778 and backed by a three-year NXT Power warranty. That warranty covers components and internal batteries from the ship date. Standard USB communication supports monitored shutdown on Windows hosts.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLine-interactive uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU250-GL-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive, true sine wave, isolated (AC and DC output)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e250 VA \/ 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (range 96–144 VAC), 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15P, fixed 6 ft line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e(5) NEMA 5-15R plus (1) terminal block for DC output\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDC Output\u003c\/td\u003e\n\u003ctd\u003e24.0 VDC @ 3.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±10% of nominal (on mains input)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e≥90% AC-AC; ≥82% DC-AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e6–9 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate valve-regulated sealed lead-acid (VRLA); Qty 1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 7 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 90%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤40 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e10.5 × 5.8 × 12.6 in (267 × 147 × 318 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 31 lb (14 kg); Shipping 37 lb (17 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, FCC Part 15 Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU250-GL-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity PRO Desktop UPS, 120 VAC 60 Hz\u003c\/td\u003e\n\u003ctd\u003e250 VA \/ 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed more headroom? The NPTU400-GL-N steps up to 400 VA \/ 320 W in the same isolated desktop form factor.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated Desktop UPS\u003c\/h2\u003e\n\u003cp\u003eMatching a desktop UPS to a bench comes down to load type, not just outage runtime. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size the UPS above your combined load; the NPTU250-GL-N supports up to 200 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — an isolation transformer blocks common-mode noise and ground loops that plain battery strips pass straight through.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — sensitive instruments and PFC power supplies favor true sine wave over simulated output.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC printer support\u003c\/strong\u003e — the 24 VDC rail drives compatible printers without a separate adapter.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC 60 Hz circuit and a NEMA 5-15 receptacle at the point of use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eIsolated desktop UPS units protect the low-draw electronics that fill modern labs and service counters. Data loggers, network switches, single-board controllers, pH and conductivity meters, and imaging peripherals all benefit from clean, conditioned power within the 200 W rating. Ground-loop elimination keeps networked instruments from locking up mid-run.\u003c\/p\u003e\n\u003cp\u003eBeyond the bench, the Integrity PRO Desktop suits point-of-sale terminals, receipt and ticket printers, credit-card readers, and security cameras. Conditioned power reduces nuisance faults on shared circuits, while battery backup carries connected gear through brief interruptions for an orderly shutdown.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU400-GL-N — the 400 VA \/ 320 W sibling in the same isolated desktop chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePoint-of-use protection for the benchtop instruments this UPS is sized for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/adam-equipment\"\u003eAnalytical Balances \u0026amp; Moisture Analyzers\u003c\/a\u003e — clean, stable power for precision weighing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/live-cell-imaging-systems\"\u003eLive-Cell Imaging Systems\u003c\/a\u003e — conditioned power for sensitive imaging electronics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/swift-sensors-wireless-monitoring\"\u003eSwift Sensors Wireless Monitoring\u003c\/a\u003e — keep monitoring gateways online during a power event.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/1ybo0vuv\/002-00081-nptu250-and-400-gl-n-user-manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNPTU250-GL-N \/ NPTU400-GL-N User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU250-GL-N ships as a single conditioned UPS with a fixed 6 ft line cord and internal battery installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to place an order or confirm the right configuration for your site.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NPTU250-GL-N run on a standard 120 V wall outlet?\u003c\/strong\u003e\u003cbr\u003eYes. It uses a NEMA 5-15P plug and accepts 120 VAC input across a 96–144 VAC range at 60 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the output waveform?\u003c\/strong\u003e\u003cbr\u003eTrue sine wave, suitable for PFC power supplies and instruments that reject stepped or simulated waveforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a standard battery backup?\u003c\/strong\u003e\u003cbr\u003eIt adds a low-impedance isolation transformer and NXT GROUND conditioning, which block common-mode noise and ground loops that ordinary battery strips pass through to the load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 24 VDC output power?\u003c\/strong\u003e\u003cbr\u003eThe 24 VDC rail supplies up to 3.0 A and drives compatible printers directly, eliminating a separate external adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal battery from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity PRO Desktop UPS 250VA (NPTU250-GL-N)\",\n  \"sku\": \"NPTU250-GL-N\",\n  \"mpn\": \"NPTU250-GL-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, line-interactive 250 VA \/ 200 W desktop UPS with true sine wave output, low-impedance isolation transformer, NXT GROUND conditioning, and 24 VDC output. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-desktop-ups-250va-nptu250-gl-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity PRO Desktop UPS 400VA (NPTU400-GL-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-desktop-ups-400va-nptu400-gl-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the NPTU250-GL-N run on a standard 120 V wall outlet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. It uses a NEMA 5-15P plug and accepts 120 VAC input across a 96\\u2013144 VAC range at 60 Hz.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the output waveform?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"True sine wave, suitable for PFC power supplies and instruments that reject stepped or simulated waveforms.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How is this different from a standard battery backup?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It adds a low-impedance isolation transformer and NXT GROUND conditioning, which block common-mode noise and ground loops that ordinary battery strips pass through to the load.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does the 24 VDC output power?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The 24 VDC rail supplies up to 3.0 A and drives compatible printers directly, eliminating a separate external adapter.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal battery from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity PRO Desktop UPS 250VA (NPTU250-GL-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48714049913064,"sku":"NPTU250-GL-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/images_ee3b18e5-ec26-42c2-afd1-15718be9401d.jpg?v=1783527263"},{"product_id":"nxt-power-integrity-pro-desktop-ups-400va-nptu400-gl-n","title":"NXT Power Integrity PRO Desktop UPS 400VA — Isolated Line-Interactive Power Conditioner (NPTU400-GL-N)","description":"\u003ch2\u003eNXT Power Integrity PRO Desktop UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity PRO Desktop UPS (NPTU400-GL-N)\u003c\/strong\u003e delivers 400 VA \/ 320 W of isolated, line-interactive backup power. Multi-monitor workstations, small network switches, and busier point-of-sale counters draw more current than a compact backup can carry cleanly. A low-impedance isolation transformer, surge diverter, and noise filter inside the chassis condition incoming power before disturbances reach the load.\u003c\/p\u003e\n\u003cp\u003eGalvanic isolation paired with true sine wave output protects equipment that strip-style battery backups pass disturbances straight through to. NXT GROUND circuitry removes ground loops that otherwise trigger lockups on shared benches and networked counters. A 24 VDC rail also powers compatible printers directly, so the setup skips a separate wall adapter.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and a three-year NXT Power warranty back every Integrity PRO Desktop unit, covering components and internal batteries. USB communication supports monitored, orderly shutdown on connected Windows hosts.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLine-interactive uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU400-GL-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive, true sine wave, isolated (AC and DC output)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e400 VA \/ 320 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (range 96–144 VAC), 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15P, fixed 6 ft line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e5.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e(5) NEMA 5-15R plus (1) terminal block for DC output\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDC Output\u003c\/td\u003e\n\u003ctd\u003e24.0 VDC @ 3.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±10% of nominal (on mains input)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e≥90% AC-AC; ≥82% DC-AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e6–9 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate valve-regulated sealed lead-acid (VRLA); Qty 1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 5 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 90%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤40 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e10.5 × 5.8 × 12.6 in (267 × 147 × 318 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 31 lb (14 kg); Shipping 37 lb (17 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e140 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, FCC Part 15 Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU400-GL-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity PRO Desktop UPS, 120 VAC 60 Hz\u003c\/td\u003e\n\u003ctd\u003e400 VA \/ 320 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a smaller footprint? The NPTU250-GL-N covers 250 VA \/ 200 W in the same isolated desktop chassis.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated Desktop UPS\u003c\/h2\u003e\n\u003cp\u003eMatching a desktop UPS to a bench comes down to load type, not just outage runtime. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size the UPS above your combined load; the NPTU400-GL-N supports up to 320 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — an isolation transformer blocks common-mode noise and ground loops that plain battery strips pass straight through.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits PFC power supplies and instruments that reject stepped or simulated output.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC printer support\u003c\/strong\u003e — the 24 VDC rail drives compatible printers without a separate adapter.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC 60 Hz circuit and a NEMA 5-15 receptacle at the point of use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eDesktop UPS units protect low-draw electronics common on lab benches and service counters. Data loggers, network switches, single-board controllers, and benchtop meters all stay within the 320 W rating comfortably. Ground-loop elimination keeps networked instruments from locking up mid-run on shared circuits.\u003c\/p\u003e\n\u003cp\u003eRetail and back-office settings benefit too, including multi-register POS clusters, ticket printers, and card readers pulling combined load. Conditioned power cuts nuisance faults on shared circuits, while battery runtime carries connected gear through short outages for a clean shutdown.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU250-GL-N — the 250 VA \/ 200 W sibling in the same isolated desktop chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePoint-of-use protection for the benchtop instruments this UPS is sized for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/adam-equipment\"\u003eAnalytical Balances \u0026amp; Moisture Analyzers\u003c\/a\u003e — clean, stable power for precision weighing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/live-cell-imaging-systems\"\u003eLive-Cell Imaging Systems\u003c\/a\u003e — conditioned power for sensitive imaging electronics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/swift-sensors-wireless-monitoring\"\u003eSwift Sensors Wireless Monitoring\u003c\/a\u003e — keep monitoring gateways online during a power event.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/1ybo0vuv\/002-00081-nptu250-and-400-gl-n-user-manual.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNPTU250-GL-N \/ NPTU400-GL-N User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU400-GL-N ships as a single conditioned UPS with a fixed 6 ft line cord and internal battery installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your site.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NPTU400-GL-N run on a standard 120 V wall outlet?\u003c\/strong\u003e\u003cbr\u003eYes. It uses a NEMA 5-15P plug and accepts 120 VAC input across a 96–144 VAC range at 60 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the output waveform?\u003c\/strong\u003e\u003cbr\u003eTrue sine wave, suitable for PFC power supplies and instruments that reject stepped or simulated waveforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a standard battery backup?\u003c\/strong\u003e\u003cbr\u003eIt adds a low-impedance isolation transformer and NXT GROUND conditioning, blocking common-mode noise and ground loops that ordinary battery strips pass through to the load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 24 VDC output power?\u003c\/strong\u003e\u003cbr\u003eThe 24 VDC rail supplies up to 3.0 A and drives compatible printers directly, eliminating a separate external adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal battery from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity PRO Desktop UPS 400VA (NPTU400-GL-N)\",\n  \"sku\": \"NPTU400-GL-N\",\n  \"mpn\": \"NPTU400-GL-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, line-interactive 400 VA \/ 320 W desktop UPS with true sine wave output, low-impedance isolation transformer, NXT GROUND conditioning, and 24 VDC output. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-desktop-ups-400va-nptu400-gl-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity PRO Desktop UPS 250VA (NPTU250-GL-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-desktop-ups-250va-nptu250-gl-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the NPTU400-GL-N run on a standard 120 V wall outlet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. It uses a NEMA 5-15P plug and accepts 120 VAC input across a 96\\u2013144 VAC range at 60 Hz.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the output waveform?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"True sine wave, suitable for PFC power supplies and instruments that reject stepped or simulated waveforms.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How is this different from a standard battery backup?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It adds a low-impedance isolation transformer and NXT GROUND conditioning, blocking common-mode noise and ground loops that ordinary battery strips pass through to the load.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does the 24 VDC output power?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The 24 VDC rail supplies up to 3.0 A and drives compatible printers directly, eliminating a separate external adapter.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal battery from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity PRO Desktop UPS 400VA (NPTU400-GL-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771816620264,"sku":"NPTU400-GL-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-pro-desktop-0_web-2-0_78a1a181-c49a-48ce-bb42-91d88ca2c146.png?v=1784386941"},{"product_id":"nxt-power-integrity-pro-standard-ups-600va-nptu600-l-n","title":"NXT Power Integrity PRO Standard UPS 600VA — Isolated Line-Interactive Power Conditioner (NPTU600-L-N)","description":"\u003ch2\u003eNXT Power Integrity PRO Standard UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity PRO Standard UPS (NPTU600-L-N)\u003c\/strong\u003e delivers 600 VA \/ 540 W of isolated, line-interactive backup power for analytical instruments and lab electronics. A pure sine wave inverter and internal isolation transformer condition incoming power before disturbances reach sensitive circuitry. Two programmable outlet groups let a single unit sequence connected devices independently.\u003c\/p\u003e\n\u003cp\u003eIsolation keeps common-mode noise below 10 V and neutral-to-ground noise below 0.5 V, a level bench electronics require but standard backups rarely hit. Detachable IEC 320 line cords simplify service, and auto-sensing 50\/60 Hz input covers both domestic and imported instruments. RS-232 and USB ports pair with the optional SNMP slot for networked monitoring.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and a three-year warranty cover the chassis, electronics, and internal batteries on every unit. Transfer time stays under 6 ms typical, fast enough to protect equipment that faults on longer switchover gaps.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU600-L-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLine-interactive uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e600 VA \/ 540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e5.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive, isolated, pure sine wave output\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (range 96–144 VAC), 50\/60 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 320 C-14, detachable line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eAC outlets with two independently programmable outlet groups\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e2–6 ms typical (12 ms maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eIsolation Let-Through\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 V normal mode, \u0026lt;0.5 V neutral-to-ground (ANSI\/IEEE C62.41 Cat. A \u0026amp; B)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eUSB and RS-232; intelligent slot for optional SNMP adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;43 dB on line power (≤70% load); \u0026lt;60 dB on battery\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eUL1778\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, chassis, electronics, and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e(2) 12 V \/ 7 Ah VRLA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (D × W × H)\u003c\/td\u003e\n\u003ctd\u003e17.7 × 7.0 × 9.3 in (450 × 180 × 236 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNet 46.1 lb (20.9 kg); Shipping 52.7 lb (23.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU600-L-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity PRO Standard UPS, 120 VAC 50\/60 Hz\u003c\/td\u003e\n\u003ctd\u003e600 VA \/ 540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed more headroom? The NPTU800-L-N, NPTU1100-L-N, and NPTU1500-L-N step up to 720 W, 990 W, and 1296 W in the same isolated Standard chassis family.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a Standard-line UPS for lab electronics comes down to more than outage runtime. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined instrument load; the NPTU600-L-N supports up to 540 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — an internal isolation transformer holds noise below 10 V normal mode, protecting instruments a standard backup would let noise reach.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — pure sine wave output matches utility power and avoids the stepped waveforms that trip instrument power supplies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — USB and RS-232 ports, plus an optional SNMP slot, support monitored shutdown across a lab network.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC 50\/60 Hz circuit; the detachable IEC 320 cord simplifies replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eIsolated Standard UPS units are built for the analytical instruments that fill working labs. HPLC detectors, spectrophotometers, balances, and data-acquisition systems all benefit from noise-free, regulated power within the 540 W rating. Isolation prevents ground loops that otherwise corrupt readings on shared benches.\u003c\/p\u003e\n\u003cp\u003eProgrammable outlet groups let a single NPTU600-L-N sequence a detector and its controller, or shed a non-critical load first during an extended outage. Server closets and network racks supporting lab data systems suit the same isolated, pure sine wave output.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU800-L-N — steps up to 800 VA \/ 720 W in the same isolated Standard chassis.\u003c\/li\u003e\n  \u003cli\u003eNPTU1100-L-N and NPTU1500-L-N — 1100 VA and 1440 VA models for heavier instrument loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLab loads commonly paired with this capacity for conditioned power and outage ride-through:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/adam-equipment\"\u003eAnalytical Balances \u0026amp; Moisture Analyzers\u003c\/a\u003e — clean, stable power for precision weighing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/kfylao4x\/022-00080-user-manual-nptu600-to-nptu1500-l-medical-and-non-medical.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNPTU600 to NPTU1500-L User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU600-L-N ships as a complete conditioned UPS with a detachable IEC 320 line cord and internal batteries installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your instruments.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can the NPTU600-L-N support?\u003c\/strong\u003e\u003cbr\u003eUp to 600 VA \/ 540 W continuous, backed by two (2) 12 V \/ 7 Ah VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does it use an isolation transformer instead of a simple inverter?\u003c\/strong\u003e\u003cbr\u003eIsolation holds common-mode noise under 0.5 V and normal-mode noise under 10 V, protecting instrument electronics that ordinary backups pass disturbances through to.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I sequence which devices power on first?\u003c\/strong\u003e\u003cbr\u003eYes. Two programmable outlet groups let you stage a detector, controller, or auxiliary device independently.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eUSB and RS-232 ports are standard, and an intelligent slot accepts an optional SNMP adapter for network monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering the chassis, electronics, and internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity PRO Standard UPS 600VA (NPTU600-L-N)\",\n  \"sku\": \"NPTU600-L-N\",\n  \"mpn\": \"NPTU600-L-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, line-interactive 600 VA \/ 540 W UPS with pure sine wave output, internal isolation transformer, and programmable outlet groups for analytical instruments and lab electronics. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-standard-ups-600va-nptu600-l-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity PRO Standard UPS 800VA (NPTU800-L-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-standard-ups-800va-nptu800-l-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can the NPTU600-L-N support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 600 VA \/ 540 W continuous, backed by two (2) 12 V \/ 7 Ah VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Why does it use an isolation transformer instead of a simple inverter?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Isolation holds common-mode noise under 0.5 V and normal-mode noise under 10 V, protecting instrument electronics that ordinary backups pass disturbances through to.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I sequence which devices power on first?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. Two programmable outlet groups let you stage a detector, controller, or auxiliary device independently.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"USB and RS-232 ports are standard, and an intelligent slot accepts an optional SNMP adapter for network monitoring.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering the chassis, electronics, and internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity PRO Standard UPS 600VA (NPTU600-L-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771816653032,"sku":"NPTU600-L-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-pro-600-800va-0_web.png?v=1784386947"},{"product_id":"nxt-power-integrity-pro-standard-ups-800va-nptu800-l-n","title":"NXT Power Integrity PRO Standard UPS 800VA — Isolated Line-Interactive Power Conditioner (NPTU800-L-N)","description":"\u003ch2\u003eNXT Power Integrity PRO Standard UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity PRO Standard UPS (NPTU800-L-N)\u003c\/strong\u003e supplies 800 VA \/ 720 W of isolated, line-interactive backup power for lab electronics that outgrow a smaller unit. An internal isolation transformer and pure sine wave inverter clean incoming power ahead of the load. Two programmable outlet groups allow staged power-up and shutdown across connected devices.\u003c\/p\u003e\n\u003cp\u003eCommon-mode noise stays under 0.5 V and normal-mode noise under 10 V, isolation levels that protect sensitive detector electronics. The detachable IEC 320 cord and 50\/60 Hz auto-sensing input work across domestic and international instruments. USB and RS-232 ports pair with an optional SNMP slot for network monitoring.\u003c\/p\u003e\n\u003cp\u003eA three-year warranty covers the chassis, electronics, and internal batteries, backed by UL1778 listing. Typical transfer time runs under 6 ms, fast enough that connected instruments rarely notice a mains event.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU800-L-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLine-interactive uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e800 VA \/ 720 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e6.66 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive, isolated, pure sine wave output\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (range 96–144 VAC), 50\/60 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 320 C-14, detachable line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eAC outlets with two independently programmable outlet groups\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e2–6 ms typical (12 ms maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eIsolation Let-Through\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 V normal mode, \u0026lt;0.5 V neutral-to-ground (ANSI\/IEEE C62.41 Cat. A \u0026amp; B)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eUSB and RS-232; intelligent slot for optional SNMP adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;43 dB on line power (≤70% load); \u0026lt;60 dB on battery\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eUL1778\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, chassis, electronics, and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e(2) 12 V \/ 9 Ah VRLA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (D × W × H)\u003c\/td\u003e\n\u003ctd\u003e17.7 × 7.0 × 9.3 in (450 × 180 × 236 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNet 48.2 lb (21.9 kg); Shipping 54.9 lb (24.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU800-L-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity PRO Standard UPS, 120 VAC 50\/60 Hz\u003c\/td\u003e\n\u003ctd\u003e800 VA \/ 720 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a different capacity? The NPTU600-L-N covers 540 W, while the NPTU1100-L-N and NPTU1500-L-N scale up to 990 W and 1296 W.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a Standard-line UPS for lab electronics comes down to more than outage runtime. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined load; the NPTU800-L-N supports up to 720 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — isolation blocks common-mode noise that a standard battery backup passes straight through to sensitive detectors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — pure sine wave output matches utility power, avoiding stepped waveforms that trip sensitive power supplies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — USB, RS-232, and an optional SNMP slot support monitored shutdown on a lab network.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC 50\/60 Hz circuit; the detachable IEC 320 cord simplifies field replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eAnalytical instruments with heavier draw suit the NPTU800-L-N well. GC and LC pumps, larger balances, and multi-module detector stacks stay within its 720 W rating while isolation keeps electrical noise off sensitive signal paths. Ground-loop elimination matters most on benches sharing a single circuit with other equipment.\u003c\/p\u003e\n\u003cp\u003eLab IT infrastructure benefits equally, including switches, servers, and data-acquisition racks supporting instrument networks. Programmable outlet groups let critical acquisition hardware stay powered while non-essential peripherals shed load during an extended outage.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU600-L-N — a 540 W option in the same isolated Standard chassis.\u003c\/li\u003e\n  \u003cli\u003eNPTU1100-L-N and NPTU1500-L-N — 1100 VA and 1440 VA models for heavier instrument loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLab loads commonly paired with this capacity for conditioned power and outage ride-through:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/adam-equipment\"\u003eAnalytical Balances \u0026amp; Moisture Analyzers\u003c\/a\u003e — clean, stable power for precision weighing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/kfylao4x\/022-00080-user-manual-nptu600-to-nptu1500-l-medical-and-non-medical.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNPTU600 to NPTU1500-L User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU800-L-N ships as a complete conditioned UPS with a detachable IEC 320 line cord and internal batteries installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your instruments.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can the NPTU800-L-N support?\u003c\/strong\u003e\u003cbr\u003eUp to 800 VA \/ 720 W continuous, backed by two (2) 12 V \/ 9 Ah VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is isolation different from a standard UPS?\u003c\/strong\u003e\u003cbr\u003eIt holds common-mode noise under 0.5 V and normal-mode noise under 10 V, levels a standard line-interactive backup does not guarantee.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan outlets be sequenced?\u003c\/strong\u003e\u003cbr\u003eYes, two programmable outlet groups allow independent staging of connected devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support network monitoring?\u003c\/strong\u003e\u003cbr\u003eUSB and RS-232 are standard, with an intelligent slot for an optional SNMP adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the warranty term?\u003c\/strong\u003e\u003cbr\u003eThree years, covering the chassis, electronics, and internal batteries.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity PRO Standard UPS 800VA (NPTU800-L-N)\",\n  \"sku\": \"NPTU800-L-N\",\n  \"mpn\": \"NPTU800-L-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, line-interactive 800 VA \/ 720 W UPS with pure sine wave output, internal isolation transformer, and programmable outlet groups for analytical instruments and lab electronics. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-standard-ups-800va-nptu800-l-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity PRO Standard UPS 1100VA (NPTU1100-L-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-standard-ups-1100va-nptu1100-l-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can the NPTU800-L-N support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 800 VA \/ 720 W continuous, backed by two (2) 12 V \/ 9 Ah VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How is isolation different from a standard UPS?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It holds common-mode noise under 0.5 V and normal-mode noise under 10 V, levels a standard line-interactive backup does not guarantee.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can outlets be sequenced?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, two programmable outlet groups allow independent staging of connected devices.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support network monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"USB and RS-232 are standard, with an intelligent slot for an optional SNMP adapter.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What's the warranty term?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering the chassis, electronics, and internal batteries.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity PRO Standard UPS 800VA (NPTU800-L-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771816849640,"sku":"NPTU800-L-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-pro-600-800va-0_web_56eb8774-5371-440f-8697-687ab5e5c27f.png?v=1784386951"},{"product_id":"nxt-power-integrity-pro-standard-ups-1100va-nptu1100-l-n","title":"NXT Power Integrity PRO Standard UPS 1100VA — Isolated Line-Interactive Power Conditioner (NPTU1100-L-N)","description":"\u003ch2\u003eNXT Power Integrity PRO Standard UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity PRO Standard UPS (NPTU1100-L-N)\u003c\/strong\u003e provides 1100 VA \/ 990 W of isolated backup power for larger instrument stacks. Four internal batteries extend runtime while the isolation transformer and pure sine wave inverter keep output clean. Two programmable outlet groups let critical and secondary loads shut down on separate schedules.\u003c\/p\u003e\n\u003cp\u003eIsolation performance matches the rest of the Standard line: common-mode noise under 0.5 V, normal-mode noise under 10 V. A detachable IEC 320 cord and 50\/60 Hz auto-sensing input simplify deployment across sites. USB, RS-232, and an optional SNMP slot cover monitored shutdown and remote alerts.\u003c\/p\u003e\n\u003cp\u003eEvery NPTU1100-L-N carries UL1778 listing and NXT Power's three-year warranty on the chassis, electronics, and batteries. Typical transfer time stays under 6 ms, well inside most instrument power supplies' ride-through window.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU1100-L-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLine-interactive uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e1100 VA \/ 990 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e9.17 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive, isolated, pure sine wave output\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (range 96–144 VAC), 50\/60 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 320 C-14, detachable line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eAC outlets with two independently programmable outlet groups\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e2–6 ms typical (12 ms maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eIsolation Let-Through\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 V normal mode, \u0026lt;0.5 V neutral-to-ground (ANSI\/IEEE C62.41 Cat. A \u0026amp; B)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eUSB and RS-232; intelligent slot for optional SNMP adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;43 dB on line power (≤70% load); \u0026lt;60 dB on battery\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eUL1778\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, chassis, electronics, and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e(4) 12 V \/ 7 Ah VRLA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (D × W × H)\u003c\/td\u003e\n\u003ctd\u003e20.7 × 8.7 × 10 in (525 × 220 × 254 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNet 82.9 lb (37.6 kg); Shipping 88.8 lb (40.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU1100-L-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity PRO Standard UPS, 120 VAC 50\/60 Hz\u003c\/td\u003e\n\u003ctd\u003e1100 VA \/ 990 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a different capacity? The NPTU600-L-N and NPTU800-L-N cover 540 W and 720 W, while the NPTU1500-L-N scales up to 1296 W.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a Standard-line UPS for lab electronics comes down to more than outage runtime. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined load; the NPTU1100-L-N supports up to 990 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — four internal batteries and isolation together protect multi-module instrument stacks that a standard backup can't clean or carry.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — pure sine wave output avoids the stepped waveforms that disrupt sensitive detector power supplies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — USB, RS-232, and an optional SNMP slot support monitored, staged shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC 50\/60 Hz circuit; the detachable IEC 320 cord simplifies service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eMulti-module analytical systems draw enough current that the 1100 VA rating becomes the practical minimum. LC-MS front ends, multi-detector GC stacks, and paired balance-and-printer setups run within the 990 W envelope. Isolation keeps ground loops off shared-bench wiring.\u003c\/p\u003e\n\u003cp\u003eServer racks supporting instrument data pipelines and networked LIMS terminals draw similarly steady current. Programmable outlet groups keep acquisition hardware live while auxiliary displays or printers shed load first.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU600-L-N and NPTU800-L-N — 540 W and 720 W options in the same isolated Standard chassis family.\u003c\/li\u003e\n  \u003cli\u003eNPTU1500-L-N — the 1296 W model at the top of the Standard line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLab loads commonly paired with this capacity for conditioned power and outage ride-through:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/adam-equipment\"\u003eAnalytical Balances \u0026amp; Moisture Analyzers\u003c\/a\u003e — clean, stable power for precision weighing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/kfylao4x\/022-00080-user-manual-nptu600-to-nptu1500-l-medical-and-non-medical.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNPTU600 to NPTU1500-L User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU1100-L-N ships as a complete conditioned UPS with a detachable IEC 320 line cord and internal batteries installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your instruments.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can the NPTU1100-L-N support?\u003c\/strong\u003e\u003cbr\u003eUp to 1100 VA \/ 990 W continuous, backed by four (4) 12 V \/ 7 Ah VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy four batteries instead of two?\u003c\/strong\u003e\u003cbr\u003eThe higher capacity rating needs more stored energy; four batteries deliver adequate runtime at the 990 W load level.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I stage shutdown across devices?\u003c\/strong\u003e\u003cbr\u003eYes, two programmable outlet groups allow independent sequencing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat monitoring options exist?\u003c\/strong\u003e\u003cbr\u003eUSB and RS-232 are built in, with an intelligent slot for an optional SNMP adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the warranty term?\u003c\/strong\u003e\u003cbr\u003eThree years, covering the chassis, electronics, and internal batteries.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity PRO Standard UPS 1100VA (NPTU1100-L-N)\",\n  \"sku\": \"NPTU1100-L-N\",\n  \"mpn\": \"NPTU1100-L-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, line-interactive 1100 VA \/ 990 W UPS with pure sine wave output, internal isolation transformer, and programmable outlet groups for multi-module analytical instruments. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-standard-ups-1100va-nptu1100-l-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity PRO Standard UPS 1500VA (NPTU1500-L-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-standard-ups-1500va-nptu1500-l-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can the NPTU1100-L-N support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 1100 VA \/ 990 W continuous, backed by four (4) 12 V \/ 7 Ah VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Why four batteries instead of two?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The higher capacity rating needs more stored energy; four batteries deliver adequate runtime at the 990 W load level.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I stage shutdown across devices?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, two programmable outlet groups allow independent sequencing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What monitoring options exist?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"USB and RS-232 are built in, with an intelligent slot for an optional SNMP adapter.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What's the warranty term?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering the chassis, electronics, and internal batteries.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity PRO Standard UPS 1100VA (NPTU1100-L-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771816882408,"sku":"NPTU1100-L-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-pro-1100-1500-0_web.png?v=1784386956"},{"product_id":"nxt-power-integrity-pro-standard-ups-1500va-nptu1500-l-n","title":"NXT Power Integrity PRO Standard UPS 1500VA — Isolated Line-Interactive Power Conditioner (NPTU1500-L-N)","description":"\u003ch2\u003eNXT Power Integrity PRO Standard UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity PRO Standard UPS (NPTU1500-L-N)\u003c\/strong\u003e tops the Standard line at 1440 VA \/ 1296 W of isolated, line-interactive backup power. Four higher-capacity batteries extend runtime under heavier loads while the isolation transformer and pure sine wave inverter keep output clean. Two programmable outlet groups let critical instruments outlast secondary peripherals during an outage.\u003c\/p\u003e\n\u003cp\u003eIsolation performance holds to the same standard across the line: common-mode noise under 0.5 V, normal-mode noise under 10 V. A detachable IEC 320 cord and 50\/60 Hz auto-sensing input simplify deployment across facilities. USB, RS-232, and an optional SNMP slot support networked monitoring and alerts.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and a three-year warranty cover the chassis, electronics, and batteries from the date of shipment. Typical transfer time stays under 6 ms, comfortably inside the ride-through window of most instrument power supplies.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU1500-L-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLine-interactive uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e1440 VA \/ 1296 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e12.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eLine interactive, isolated, pure sine wave output\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (range 96–144 VAC), 50\/60 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eIEC 320 C-14, detachable line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eAC outlets with two independently programmable outlet groups\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003e2–6 ms typical (12 ms maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eIsolation Let-Through\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 V normal mode, \u0026lt;0.5 V neutral-to-ground (ANSI\/IEEE C62.41 Cat. A \u0026amp; B)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eUSB and RS-232; intelligent slot for optional SNMP adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;43 dB on line power (≤70% load); \u0026lt;60 dB on battery\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eUL1778\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, chassis, electronics, and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e(4) 12 V \/ 9 Ah VRLA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (D × W × H)\u003c\/td\u003e\n\u003ctd\u003e20.7 × 8.7 × 10 in (525 × 220 × 254 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNet 87.3 lb (39.6 kg); Shipping 93.3 lb (42.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU1500-L-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity PRO Standard UPS, 120 VAC 50\/60 Hz\u003c\/td\u003e\n\u003ctd\u003e1440 VA \/ 1296 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a smaller footprint? The NPTU600-L-N, NPTU800-L-N, and NPTU1100-L-N cover 540 W, 720 W, and 990 W in the same isolated Standard chassis family.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a Standard-line UPS for lab electronics comes down to more than outage runtime. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined load; the NPTU1500-L-N supports up to 1296 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — higher-capacity batteries and isolation together protect the largest instrument stacks in the Standard line.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — pure sine wave output avoids stepped waveforms that disrupt sensitive detector power supplies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — USB, RS-232, and an optional SNMP slot support monitored, staged shutdown across a rack.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC 50\/60 Hz circuit; the detachable IEC 320 cord simplifies service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eThe largest analytical setups and multi-instrument benches draw close to the 1296 W ceiling this unit supports. Preparative HPLC systems, paired GC-MS front ends, and racks combining several detectors all fit within its output envelope. Isolation keeps that combined load from introducing ground-loop noise on a shared circuit.\u003c\/p\u003e\n\u003cp\u003eServer and network infrastructure supporting lab-wide data acquisition draws similarly steady current at this capacity tier. Programmable outlet groups keep acquisition hardware running while less critical displays or printers shed load first during an extended outage.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU600-L-N and NPTU800-L-N — 540 W and 720 W options in the same isolated Standard chassis family.\u003c\/li\u003e\n  \u003cli\u003eNPTU1100-L-N — the 990 W model directly below this one in the Standard line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLab loads commonly paired with this capacity for conditioned power and outage ride-through:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/adam-equipment\"\u003eAnalytical Balances \u0026amp; Moisture Analyzers\u003c\/a\u003e — clean, stable power for precision weighing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/kfylao4x\/022-00080-user-manual-nptu600-to-nptu1500-l-medical-and-non-medical.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNPTU600 to NPTU1500-L User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU1500-L-N ships as a complete conditioned UPS with a detachable IEC 320 line cord and internal batteries installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your instruments.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the actual output rating?\u003c\/strong\u003e\u003cbr\u003e1440 VA \/ 1296 W continuous — NXT Power markets the model as 1500VA, but the datasheet rates it at 1440 VA \/ 1296 W.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can it support?\u003c\/strong\u003e\u003cbr\u003eUp to 1296 W continuous, backed by four (4) 12 V \/ 9 Ah VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is isolation different from a standard UPS?\u003c\/strong\u003e\u003cbr\u003eIt holds common-mode noise under 0.5 V and normal-mode noise under 10 V, protecting instrument electronics a standard backup would let disturbances reach.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support network monitoring?\u003c\/strong\u003e\u003cbr\u003eUSB and RS-232 are standard, with an intelligent slot for an optional SNMP adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the warranty term?\u003c\/strong\u003e\u003cbr\u003eThree years, covering the chassis, electronics, and internal batteries.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity PRO Standard UPS 1500VA (NPTU1500-L-N)\",\n  \"sku\": \"NPTU1500-L-N\",\n  \"mpn\": \"NPTU1500-L-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, line-interactive 1440 VA \/ 1296 W UPS with pure sine wave output, internal isolation transformer, and programmable outlet groups for the largest analytical instrument stacks. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-standard-ups-1500va-nptu1500-l-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity PRO Standard UPS 1100VA (NPTU1100-L-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-pro-standard-ups-1100va-nptu1100-l-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What's the actual output rating?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"1440 VA \/ 1296 W continuous \\u2014 NXT Power markets the model as 1500VA, but the datasheet rates it at 1440 VA \/ 1296 W.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can it support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 1296 W continuous, backed by four (4) 12 V \/ 9 Ah VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How is isolation different from a standard UPS?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It holds common-mode noise under 0.5 V and normal-mode noise under 10 V, protecting instrument electronics a standard backup would let disturbances reach.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support network monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"USB and RS-232 are standard, with an intelligent slot for an optional SNMP adapter.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What's the warranty term?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering the chassis, electronics, and internal batteries.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity PRO Standard UPS 1500VA (NPTU1500-L-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771816947944,"sku":"NPTU1500-L-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-pro-1100-1500-0_web_3d205e68-2223-41c7-a426-d1b1668f4a79.png?v=1784386961"},{"product_id":"nxt-power-integrity-max-rt-ups-800va-nptu800-or-n","title":"NXT Power Integrity Max R\/T UPS 800VA — Isolated Online Double-Conversion Rackmount 2U UPS (NPTU800-OR-N)","description":"\u003ch2\u003eNXT Power Integrity Max R\/T UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max R\/T UPS (NPTU800-OR-N)\u003c\/strong\u003e delivers 800 VA \/ 720 W of isolated, online double-conversion power from a compact 2U chassis. A continuous double-conversion topology regenerates output continuously, so connected gear sees zero transfer gap during a mains event. An internal isolation transformer removes common-mode noise before it reaches rack-mounted electronics.\u003c\/p\u003e\n\u003cp\u003eSix NEMA 5-15R outlets accept standard equipment cords. A factory-default 120 VAC input covers most North American racks, and 100 VAC is selectable where needed. RS-232 and USB ports handle local monitoring, and an internal SNMP slot is available for network alerts.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and a three-year NXT Power warranty cover components and internal batteries. Three internal VRLA batteries deliver a 36 VDC bus, sized for a short, clean ride-through rather than extended runtime.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU800-OR-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion, true sine wave output, internal isolation transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e800 VA \/ 720 W (666\/599 W @100VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC factory default (100 VAC selectable), 90–150 VAC range above 75% load, 50\/60 Hz auto-detect\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15P, fixed 6 ft line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e10.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e(6) NEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±2.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥84.0%; DC-AC ≥82.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 3 (36 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 8 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB, DB-9 dry contacts; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage −15 to 55 °C, transit −15 to 60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤50 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e467 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e3.46 × 17.32 × 27.68 in (88 × 440 × 703 mm), 2U rack-tower\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 63 lb (29 kg); Shipping 72 lb (33 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU800-OR-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max R\/T UPS, 2U rack-tower, 120 VAC\u003c\/td\u003e\n\u003ctd\u003e800 VA \/ 720 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed more headroom? The NPTU1100-OR-N and NPTU1500-OR-N step up to 990 W and 1290 W in the same 2U rack-tower chassis.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated Rack Tower UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a rack-tower UPS comes down to rack load and how it's isolated, not just runtime. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined rack load; the NPTU800-OR-N supports up to 720 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — online double-conversion output stays isolated and regenerated at all times, not just after a transfer event.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits networking and instrument power supplies that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, and an optional SNMP slot support monitored shutdown across a rack.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC circuit and rack space for a 2U, NEMA 5-15P-powered unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eRack-mounted lab and IT equipment benefits most from the NPTU800-OR-N's compact 2U footprint. Network switches, small servers, and single-board data-acquisition racks stay within its 720 W rating while double-conversion output removes upstream noise. Shared-rack wiring is exactly where ground-loop noise tends to accumulate.\u003c\/p\u003e\n\u003cp\u003eInstrument racks in imaging suites and diagnostic labs suit the same profile, especially alongside networking gear. Zero transfer-time double conversion matters most for equipment that faults on even a brief gap.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU1100-OR-N — the 990 W step-up in the same 2U rack-tower chassis.\u003c\/li\u003e\n  \u003cli\u003eNPTU1500-OR-N — the 1290 W model at the top of the R\/T line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRack-mounted data and monitoring systems this UPS protects:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/multi-channel-data-loggers\"\u003eMulti-Channel Data Loggers\u003c\/a\u003e — uninterrupted logging through outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/swift-sensors-wireless-monitoring\"\u003eSwift Sensors Wireless Monitoring\u003c\/a\u003e — keep monitoring gateways online during a power event.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/0arbrf2t\/022-00051-nptu800-to-1500-o-r-user-manual-rev-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNPTU800 to NPTU1500-O-R User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU800-OR-N ships as a complete rack-tower UPS with rack ears, tower feet, and internal batteries installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your rack.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NPTU800-OR-N mount in a standard rack?\u003c\/strong\u003e\u003cbr\u003eYes. It ships as a 2U unit with rack ears and tower feet, so it mounts in a standard rack or stands alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does double-conversion mean for connected equipment?\u003c\/strong\u003e\u003cbr\u003eOutput power is continuously regenerated from the isolated DC bus, so there's no transfer gap when mains power fails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it run on 100 VAC instead of 120 VAC?\u003c\/strong\u003e\u003cbr\u003eYes, 100 VAC is a selectable configuration; 120 VAC ships as the factory default.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max R\/T UPS 800VA (NPTU800-OR-N)\",\n  \"sku\": \"NPTU800-OR-N\",\n  \"mpn\": \"NPTU800-OR-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 800 VA \/ 720 W rack-tower UPS with true sine wave output and internal isolation transformer. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-rt-ups-800va-nptu800-or-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max R\/T UPS 1100VA (NPTU1100-OR-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-rt-ups-1100va-nptu1100-or-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the NPTU800-OR-N mount in a standard rack?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. It ships as a 2U unit with rack ears and tower feet, so it mounts in a standard rack or stands alone.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does double-conversion mean for connected equipment?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Output power is continuously regenerated from the isolated DC bus, so there's no transfer gap when mains power fails.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can it run on 100 VAC instead of 120 VAC?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, 100 VAC is a selectable configuration; 120 VAC ships as the factory default.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max R\/T UPS 800VA (NPTU800-OR-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771816980712,"sku":"NPTU800-OR-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-max-rt-standing-0_web.png?v=1784386966"},{"product_id":"nxt-power-integrity-max-rt-ups-1100va-nptu1100-or-n","title":"NXT Power Integrity Max R\/T UPS 1100VA — Isolated Online Double-Conversion Rackmount 2U UPS (NPTU1100-OR-N)","description":"\u003ch2\u003eNXT Power Integrity Max R\/T UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max R\/T UPS (NPTU1100-OR-N)\u003c\/strong\u003e supplies 1100 VA \/ 990 W of isolated, online double-conversion power from the same 2U rack-tower chassis as its siblings. Continuous double-conversion regenerates output power at all times, giving connected rack gear a zero-gap transfer during mains events. An internal isolation transformer strips common-mode noise before it reaches the rack.\u003c\/p\u003e\n\u003cp\u003eSix NEMA 5-15R outlets cover standard rack equipment, and input defaults to 120 VAC with a 100 VAC option available. RS-232 and USB handle local monitoring, while an internal SNMP slot supports network alerts. Rack ears and tower feet ship in the box for either mounting style.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and a three-year NXT Power warranty cover components and internal batteries on every unit. Three internal VRLA batteries form the 36 VDC bus, tuned for a short, clean ride-through rather than extended standby time.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU1100-OR-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion, true sine wave output, internal isolation transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e1100 VA \/ 990 W (916\/824 W @100VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC factory default (100 VAC selectable), 90–150 VAC range above 75% load, 50\/60 Hz auto-detect\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15P, fixed 6 ft line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e11.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e(6) NEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±2.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥84.0%; DC-AC ≥82.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 3 (36 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 5 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB, DB-9 dry contacts; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage −15 to 55 °C, transit −15 to 60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤50 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e643 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e3.46 × 17.32 × 27.68 in (88 × 440 × 703 mm), 2U rack-tower\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 63 lb (29 kg); Shipping 72 lb (33 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU1100-OR-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max R\/T UPS, 2U rack-tower, 120 VAC\u003c\/td\u003e\n\u003ctd\u003e1100 VA \/ 990 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a different capacity? The NPTU800-OR-N covers 720 W, while the NPTU1500-OR-N scales up to 1290 W in the same 2U rack-tower chassis.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated Rack Tower UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a rack-tower UPS comes down to rack load and how it's isolated, not just runtime. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined rack load; the NPTU1100-OR-N supports up to 990 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, not only after a transfer event.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits networking and instrument power supplies that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, and an optional SNMP slot support monitored shutdown across a rack.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC circuit and 2U of rack space; power connects via a fixed NEMA 5-15P cord.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eBusier rack-mounted instrument and IT loads fit the NPTU1100-OR-N's step up in capacity. Multi-port switches, small server clusters, and instrument controllers sharing a rack stay within its 990 W rating while output remains isolated and regenerated. Racks that combine networking and analytical gear are where ground-loop noise causes the most trouble, and double conversion blocks it continuously.\u003c\/p\u003e\n\u003cp\u003eDiagnostic imaging racks and multi-instrument benches with a heavier combined draw suit the same profile. Continuous double conversion protects equipment that faults on even a brief switchover, a common failure mode with simpler line-interactive backups.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU800-OR-N — the 720 W entry point in the same 2U rack-tower chassis.\u003c\/li\u003e\n  \u003cli\u003eNPTU1500-OR-N — the 1290 W model at the top of the R\/T line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRack-mounted data and monitoring systems this UPS protects:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/multi-channel-data-loggers\"\u003eMulti-Channel Data Loggers\u003c\/a\u003e — uninterrupted logging through outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/swift-sensors-wireless-monitoring\"\u003eSwift Sensors Wireless Monitoring\u003c\/a\u003e — keep monitoring gateways online during a power event.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/0arbrf2t\/022-00051-nptu800-to-1500-o-r-user-manual-rev-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNPTU800 to NPTU1500-O-R User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU1100-OR-N ships as a complete rack-tower UPS with rack ears, tower feet, and internal batteries installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your rack.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can the NPTU1100-OR-N support?\u003c\/strong\u003e\u003cbr\u003eUp to 1100 VA \/ 990 W continuous, powered from three internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does double conversion differ from a standard rack UPS?\u003c\/strong\u003e\u003cbr\u003eOutput is continuously regenerated from an isolated DC bus rather than switched during an outage, so there's no transfer gap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it mount in a standard rack?\u003c\/strong\u003e\u003cbr\u003eYes, it ships 2U with rack ears and tower feet included for either mounting style.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max R\/T UPS 1100VA (NPTU1100-OR-N)\",\n  \"sku\": \"NPTU1100-OR-N\",\n  \"mpn\": \"NPTU1100-OR-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 1100 VA \/ 990 W rack-tower UPS with true sine wave output and internal isolation transformer. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-rt-ups-1100va-nptu1100-or-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max R\/T UPS 1500VA (NPTU1500-OR-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-rt-ups-1500va-nptu1500-or-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can the NPTU1100-OR-N support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 1100 VA \/ 990 W continuous, powered from three internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does double conversion differ from a standard rack UPS?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Output is continuously regenerated from an isolated DC bus rather than switched during an outage, so there's no transfer gap.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it mount in a standard rack?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, it ships 2U with rack ears and tower feet included for either mounting style.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max R\/T UPS 1100VA (NPTU1100-OR-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817013480,"sku":"NPTU1100-OR-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-max-rt-standing-0_web_f92675ca-cc20-436d-8ca2-1ecd9843577d.png?v=1784386971"},{"product_id":"nxt-power-integrity-max-rt-ups-1500va-nptu1500-or-n","title":"NXT Power Integrity Max R\/T UPS 1500VA — Isolated Online Double-Conversion Rackmount 2U UPS (NPTU1500-OR-N)","description":"\u003ch2\u003eNXT Power Integrity Max R\/T UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max R\/T UPS (NPTU1500-OR-N)\u003c\/strong\u003e tops the rack-tower line at 1440 VA \/ 1290 W of isolated, online double-conversion power. Continuous double-conversion regenerates output at all times, so connected rack gear sees no transfer gap during a mains event. An internal isolation transformer keeps common-mode noise off the rack bus.\u003c\/p\u003e\n\u003cp\u003eSix NEMA 5-15R outlets, a factory-default 120 VAC input, and an optional 100 VAC configuration match the rest of the R\/T line. RS-232 and USB cover local monitoring, and an internal SNMP slot is available for network alerts. Rack ears and tower feet ship in the box.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and a three-year NXT Power warranty cover components and internal batteries. Three internal VRLA batteries supply the 36 VDC bus, sized for a short, clean ride-through at this higher capacity tier.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU1500-OR-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion, true sine wave output, internal isolation transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e1440 VA \/ 1290 W (1200\/1080 W @100VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC factory default (100 VAC selectable), 90–150 VAC range above 75% load, 50\/60 Hz auto-detect\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15P, fixed 6 ft line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e12.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e(6) NEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±2.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥84.0%; DC-AC ≥82.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 3 (36 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 3 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB, DB-9 dry contacts; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage −15 to 55 °C, transit −15 to 60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤50 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e838 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e3.46 × 17.32 × 27.68 in (88 × 440 × 703 mm), 2U rack-tower\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 63 lb (29 kg); Shipping 72 lb (33 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU1500-OR-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max R\/T UPS, 2U rack-tower, 120 VAC\u003c\/td\u003e\n\u003ctd\u003e1440 VA \/ 1290 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a smaller footprint? The NPTU800-OR-N and NPTU1100-OR-N cover 720 W and 990 W in the same 2U rack-tower chassis.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated Rack Tower UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a rack-tower UPS comes down to rack load and how it's isolated, not just runtime. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined rack load; the NPTU1500-OR-N supports up to 1290 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, unlike a standard backup that only engages after a transfer.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits networking and instrument power supplies that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, and an optional SNMP slot support monitored shutdown across a fully loaded rack.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC circuit and 2U of rack space; power connects via a fixed NEMA 5-15P cord.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eThe heaviest rack-mounted loads in the R\/T line fit the NPTU1500-OR-N. Dense switch stacks, multi-node servers, and instrument controllers sharing a fully loaded rack stay within its 1290 W rating. A crowded rack is exactly where isolation earns its keep against accumulated ground-loop noise.\u003c\/p\u003e\n\u003cp\u003eMulti-instrument diagnostic and imaging racks with the heaviest combined draw in this class suit the same profile. Continuous double conversion protects equipment that can't tolerate even a brief switchover, a common weak point in simpler line-interactive designs.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU800-OR-N and NPTU1100-OR-N — 720 W and 990 W options in the same 2U rack-tower chassis family.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRack-mounted data and monitoring systems this UPS protects:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/multi-channel-data-loggers\"\u003eMulti-Channel Data Loggers\u003c\/a\u003e — uninterrupted logging through outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/swift-sensors-wireless-monitoring\"\u003eSwift Sensors Wireless Monitoring\u003c\/a\u003e — keep monitoring gateways online during a power event.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/0arbrf2t\/022-00051-nptu800-to-1500-o-r-user-manual-rev-b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNPTU800 to NPTU1500-O-R User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU1500-OR-N ships as a complete rack-tower UPS with rack ears, tower feet, and internal batteries installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your rack.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the actual output rating?\u003c\/strong\u003e\u003cbr\u003e1440 VA \/ 1290 W continuous — NXT Power markets the model as 1500VA, but the datasheet rates it at 1440 VA \/ 1290 W.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can it support?\u003c\/strong\u003e\u003cbr\u003eUp to 1290 W continuous, powered from three internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it mount in a standard rack?\u003c\/strong\u003e\u003cbr\u003eYes, it ships 2U with rack ears and tower feet included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max R\/T UPS 1500VA (NPTU1500-OR-N)\",\n  \"sku\": \"NPTU1500-OR-N\",\n  \"mpn\": \"NPTU1500-OR-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 1440 VA \/ 1290 W rack-tower UPS with true sine wave output and internal isolation transformer. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-rt-ups-1500va-nptu1500-or-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max R\/T UPS 1100VA (NPTU1100-OR-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-rt-ups-1100va-nptu1100-or-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What's the actual output rating?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"1440 VA \/ 1290 W continuous \\u2014 NXT Power markets the model as 1500VA, but the datasheet rates it at 1440 VA \/ 1290 W.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can it support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 1290 W continuous, powered from three internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it mount in a standard rack?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, it ships 2U with rack ears and tower feet included.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max R\/T UPS 1500VA (NPTU1500-OR-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817046248,"sku":"NPTU1500-OR-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-max-rt-standing-0_web_19cf8866-27fe-4592-8420-70002cf3243c.png?v=1784386976"},{"product_id":"nxt-power-integrity-max-lt-ups-2000va-nptu2000-o-n","title":"NXT Power Integrity Max LT UPS 2000VA — Isolated Online Double-Conversion UPS (NPTU2000-O-N)","description":"\u003ch2\u003eNXT Power Integrity Max LT UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max LT UPS (NPTU2000-O-N)\u003c\/strong\u003e delivers 1920 VA \/ 1728 W of isolated, online double-conversion power for equipment that outgrows a rack-tower unit. Continuous double conversion regenerates output from an isolated DC bus, so connected systems see zero transfer gap during a mains event. Six internal batteries form a 72 VDC bus sized for a clean, dependable ride-through.\u003c\/p\u003e\n\u003cp\u003eA fixed NEMA 5-20P cord draws from a standard 120 VAC circuit, and output splits across one L5-30R plus six NEMA 5-20R receptacles. Where site power requires it, a 100 VAC configuration is also available. RS-232, USB, and an optional internal SNMP adapter cover local and networked monitoring.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and NXT Power's three-year warranty cover components and internal batteries. Efficiency reaches 84% AC-DC-AC, keeping heat output manageable in an equipment room running continuously.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU2000-O-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion, true sine wave output, internal isolation transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e1920 VA \/ 1728 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (100 VAC optional, derated), 90–150 VAC range above 75% load, 50\/60 Hz auto-detect\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-20P, fixed 6 ft line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e16.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e(1) NEMA L5-30R and (6) NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±2.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥84.0%; DC-AC ≥80.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 6 (72 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 4 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage\/transit −10 to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤55 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e1110 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e22.0 × 8.9 × 22.8 in (560 × 227 × 580 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 132 lb (60 kg); Shipping 145 lb (66 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU2000-O-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max LT UPS, tower, 120 VAC\u003c\/td\u003e\n\u003ctd\u003e1920 VA \/ 1728 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed more headroom? The NPTU3000-O-N steps up to 2430 W on a dedicated 120 VAC circuit, and the NPTU3000-O-NS covers 208\/240 VAC facilities.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated Max LT UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a Max LT UPS comes down to facility load and available circuits. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined load; the NPTU2000-O-N supports up to 1728 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, not only after a transfer event.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits instrument and IT power supplies that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, and an optional SNMP adapter support monitored, networked shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a 120 VAC circuit and NEMA 5-20 receptacle; a 100 VAC configuration is available where needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eLarger analytical systems that a desktop or rack-tower unit can't carry fit the NPTU2000-O-N's 1728 W rating. GC-MS and LC-MS front ends, along with multi-instrument benches drawing steady combined current, run on continuously isolated, regenerated power. Equipment rooms consolidating several instrument racks see the same benefit at a shared point of use.\u003c\/p\u003e\n\u003cp\u003eIT infrastructure supporting instrument data pipelines, including small server clusters and network cores, draws similarly steady load at this capacity. Continuous double conversion protects that infrastructure from the brief switchover gaps that simpler backups can't fully eliminate.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU3000-O-N — steps up to 2430 W on a dedicated NEMA L5-30 circuit.\u003c\/li\u003e\n  \u003cli\u003eNPTU3000-O-NS — the 208\/240 VAC configuration for facilities without standard 120 VAC distribution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHigher-draw, sample-critical equipment this UPS class conditions and bridges through outages:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/ultra-low-temperature-freezers\"\u003eUltra-Low Temperature Freezers\u003c\/a\u003e — shield -80 °C sample storage from surges, sags, and brief outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/m3tocuin\/nxt-power-2k3k-120v-pf0-9-english-user-manual-a5-_192321172093000.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIntegrity Max LT 2000\/3000 (120VAC) User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU2000-O-N ships as a complete double-conversion UPS with a fixed line cord and internal batteries installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your equipment room.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can the NPTU2000-O-N support?\u003c\/strong\u003e\u003cbr\u003eUp to 1920 VA \/ 1728 W continuous, powered from six internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does double conversion differ from a standard UPS?\u003c\/strong\u003e\u003cbr\u003eOutput is continuously regenerated from an isolated DC bus rather than switched during an outage, so there's no transfer gap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat outlets does it provide?\u003c\/strong\u003e\u003cbr\u003eOne NEMA L5-30R and six NEMA 5-20R receptacles, fed from a fixed NEMA 5-20P input cord.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max LT UPS 2000VA (NPTU2000-O-N)\",\n  \"sku\": \"NPTU2000-O-N\",\n  \"mpn\": \"NPTU2000-O-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 1920 VA \/ 1728 W UPS with true sine wave output and internal isolation transformer for larger instrument systems. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-lt-ups-2000va-nptu2000-o-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max LT UPS 3000VA (NPTU3000-O-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-lt-ups-3000va-nptu3000-o-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can the NPTU2000-O-N support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 1920 VA \/ 1728 W continuous, powered from six internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does double conversion differ from a standard UPS?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Output is continuously regenerated from an isolated DC bus rather than switched during an outage, so there's no transfer gap.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What outlets does it provide?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"One NEMA L5-30R and six NEMA 5-20R receptacles, fed from a fixed NEMA 5-20P input cord.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max LT UPS 2000VA (NPTU2000-O-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817111784,"sku":"NPTU2000-O-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-lt-1_10k.png?v=1784386983"},{"product_id":"nxt-power-integrity-max-lt-ups-3000va-nptu3000-o-n","title":"NXT Power Integrity Max LT UPS 3000VA — Isolated Online Double-Conversion UPS (NPTU3000-O-N)","description":"\u003ch2\u003eNXT Power Integrity Max LT UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max LT UPS (NPTU3000-O-N)\u003c\/strong\u003e supplies 2700 VA \/ 2430 W of isolated, online double-conversion power. It's the largest 120 VAC model in the Max LT line. This continuous double-conversion topology regenerates output from an isolated DC bus, eliminating transfer gaps during mains events.\u003c\/p\u003e\n\u003cp\u003eA fixed NEMA L5-30P cord draws from a dedicated 120 VAC circuit, and output splits across one L5-30R plus six NEMA 5-20R receptacles. RS-232, USB, and an optional internal SNMP adapter cover local and networked monitoring.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and NXT Power's three-year warranty cover components and internal batteries. AC-DC-AC efficiency reaches 84%, keeping continuous-duty heat output manageable in a dedicated equipment room.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU3000-O-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion, true sine wave output, internal isolation transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e2700 VA \/ 2430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (100 VAC optional, derated), 90–150 VAC range above 75% load, 50\/60 Hz auto-detect\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eNEMA L5-30P, fixed 6 ft line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e24.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e(1) NEMA L5-30R and (6) NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±2.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥84.0%; DC-AC ≥80.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 6 (72 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 3 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage\/transit −10 to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤55 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e1660 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e22.0 × 8.9 × 22.8 in (560 × 227 × 580 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 132 lb (60 kg); Shipping 145 lb (66 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU3000-O-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max LT UPS, tower, 120 VAC\u003c\/td\u003e\n\u003ctd\u003e2700 VA \/ 2430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a smaller footprint? The NPTU2000-O-N covers 1728 W on a standard NEMA 5-20 circuit. For 208\/240 VAC facilities, see the NPTU3000-O-NS.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated Max LT UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a Max LT UPS comes down to facility load and available circuits. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined load; the NPTU3000-O-N supports up to 2430 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, unlike backups that only switch after a transfer event.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits instrument and IT power supplies that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, and an optional SNMP adapter support monitored, networked shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm a dedicated 120 VAC circuit with a NEMA L5-30 receptacle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eThe heaviest single-circuit instrument loads in the Max LT line fit the NPTU3000-O-N's 2430 W rating. Preparative LC systems, multi-detector GC-MS stacks, and equipment rooms consolidating several racks onto one feed all run on continuously isolated, regenerated power. A dedicated L5-30 circuit keeps this unit separate from lighter general-purpose loads.\u003c\/p\u003e\n\u003cp\u003eIT infrastructure sized for a full instrument suite draws comparable steady current. Continuous double conversion removes the brief switchover gap that a simpler backup would still expose that infrastructure to.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU2000-O-N — the 1728 W entry point on a standard NEMA 5-20 circuit.\u003c\/li\u003e\n  \u003cli\u003eNPTU3000-O-NS — the same 2430 W rating configured for 208\/240 VAC facility power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHigher-draw, sample-critical equipment this UPS class conditions and bridges through outages:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/ultra-low-temperature-freezers\"\u003eUltra-Low Temperature Freezers\u003c\/a\u003e — shield -80 °C sample storage from surges, sags, and brief outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/m3tocuin\/nxt-power-2k3k-120v-pf0-9-english-user-manual-a5-_192321172093000.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIntegrity Max LT 2000\/3000 (120VAC) User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU3000-O-N ships as a complete double-conversion UPS with a fixed line cord and internal batteries installed. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your equipment room.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can the NPTU3000-O-N support?\u003c\/strong\u003e\u003cbr\u003eUp to 2700 VA \/ 2430 W continuous, powered from six internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input connection does it need?\u003c\/strong\u003e\u003cbr\u003eA fixed NEMA L5-30P cord on a dedicated 120 VAC circuit rated for 24.0 A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat outlets does it provide?\u003c\/strong\u003e\u003cbr\u003eOne NEMA L5-30R and six NEMA 5-20R receptacles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max LT UPS 3000VA (NPTU3000-O-N)\",\n  \"sku\": \"NPTU3000-O-N\",\n  \"mpn\": \"NPTU3000-O-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 2700 VA \/ 2430 W UPS with true sine wave output and internal isolation transformer for the heaviest single-circuit instrument loads. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-lt-ups-3000va-nptu3000-o-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max LT UPS 3000VA 208\/240VAC (NPTU3000-O-NS)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-lt-ups-3000va-nptu3000-o-ns\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can the NPTU3000-O-N support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 2700 VA \/ 2430 W continuous, powered from six internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What input connection does it need?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A fixed NEMA L5-30P cord on a dedicated 120 VAC circuit rated for 24.0 A.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What outlets does it provide?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"One NEMA L5-30R and six NEMA 5-20R receptacles.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max LT UPS 3000VA (NPTU3000-O-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817144552,"sku":"NPTU3000-O-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-lt-1_10k_7b268ef6-7db9-4ef9-86e7-e9a6ee18416a.png?v=1784386988"},{"product_id":"nxt-power-integrity-max-lt-ups-3000va-nptu3000-o-ns","title":"NXT Power Integrity Max LT UPS 3000VA 208\/240VAC — Isolated Online Double-Conversion UPS (NPTU3000-O-NS)","description":"\u003ch2\u003eNXT Power Integrity Max LT UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max LT UPS (NPTU3000-O-NS)\u003c\/strong\u003e delivers 2700 VA \/ 2430 W of isolated, online double-conversion power from a 208\/240 VAC-capable input. Field-configurable input lets one unit serve either a 208 VAC or 240 VAC circuit, shipping factory-set to 208 VAC. This continuous double-conversion topology regenerates output from an isolated DC bus.\u003c\/p\u003e\n\u003cp\u003eA detachable NEMA L6-30P cord draws from the selected circuit. Output delivers 240\/120 VAC across one L6-30R, one L6-20R, one 6-20R duplex, and two 5-20R duplex receptacles. RS-232, USB, and an optional internal SNMP adapter cover local and networked monitoring.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and NXT Power's three-year warranty cover components and internal batteries. AC-DC-AC efficiency reaches 84%, matching the rest of the Max LT line despite the higher input voltage.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU3000-O-NS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion, true sine wave output, internal isolation transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e2700 VA \/ 2430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208 VAC or 240 VAC, user-configurable (factory set for 208 VAC); 187–264 VAC range above 75% load, 50\/60 Hz auto-detect\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eNEMA L6-30P, detachable 8 ft line cord\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e15.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e240 \/ 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd\u003e(1) NEMA L6-30R, (1) L6-20R, (1) 6-20R duplex, (2) 5-20R duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±2.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥84.0%; DC-AC ≥80.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 6 (72 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 3 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage\/transit −10 to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤55 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e1575 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e22.0 × 8.9 × 22.8 in (560 × 227 × 580 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 132 lb (60 kg); Shipping 145 lb (66 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU3000-O-NS\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max LT UPS, tower, 208\/240 VAC (field-configurable)\u003c\/td\u003e\n\u003ctd\u003e2700 VA \/ 2430 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed standard 120 VAC service instead? The NPTU2000-O-N and NPTU3000-O-N cover 1728 W and 2430 W on 120 VAC circuits.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Isolated Max LT UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a Max LT UPS comes down to facility load and available circuits. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined load; the NPTU3000-O-NS supports up to 2430 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, unlike backups that only switch after a transfer event.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits instrument and IT power supplies that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, and an optional SNMP adapter support monitored, networked shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm 208 VAC or 240 VAC facility distribution and a NEMA L6-30 receptacle; input is field-configurable between the two.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eFacilities with 208 VAC or 240 VAC distribution are the deciding factor for the NPTU3000-O-NS. Equipment rooms already wired for 208\/240 VAC service can run instrument racks and IT infrastructure at 2430 W. Configurable input means one part number covers both common facility voltages.\u003c\/p\u003e\n\u003cp\u003eMulti-instrument suites and consolidated server rooms benefit from the mixed 240\/120 VAC output. It feeds both 240 V equipment and standard 120 V peripherals from a single unit. Continuous double conversion keeps that combined load isolated and regenerated throughout an outage.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU2000-O-N and NPTU3000-O-N — 1728 W and 2430 W models for standard 120 VAC circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHigher-draw, sample-critical equipment this UPS class conditions and bridges through outages:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/ultra-low-temperature-freezers\"\u003eUltra-Low Temperature Freezers\u003c\/a\u003e — shield -80 °C sample storage from surges, sags, and brief outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/laboratory-incubators-1\"\u003eLaboratory Incubators\u003c\/a\u003e — hold culture conditions steady through power disturbances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/m3tocuin\/nxt-power-2k3k-120v-pf0-9-english-user-manual-a5-_192321172093000.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIntegrity Max LT User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU3000-O-NS ships as a complete double-conversion UPS with a detachable line cord and internal batteries installed, field-configurable between 208 VAC and 240 VAC input. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your facility.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this two different products for 208V and 240V input?\u003c\/strong\u003e\u003cbr\u003eNo, it's one unit with field-configurable input voltage, shipped factory-set to 208 VAC and switchable to 240 VAC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can the NPTU3000-O-NS support?\u003c\/strong\u003e\u003cbr\u003eUp to 2700 VA \/ 2430 W continuous, powered from six internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat output does it provide?\u003c\/strong\u003e\u003cbr\u003e240\/120 VAC across one L6-30R, one L6-20R, one 6-20R duplex, and two 5-20R duplex receptacles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max LT UPS 3000VA 208\/240VAC (NPTU3000-O-NS)\",\n  \"sku\": \"NPTU3000-O-NS\",\n  \"mpn\": \"NPTU3000-O-NS\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 2700 VA \/ 2430 W UPS with field-configurable 208\/240 VAC input, true sine wave output, and internal isolation transformer. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-lt-ups-3000va-nptu3000-o-ns\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max LT UPS 3000VA (NPTU3000-O-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-lt-ups-3000va-nptu3000-o-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is this two different products for 208V and 240V input?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No, it's one unit with field-configurable input voltage, shipped factory-set to 208 VAC and switchable to 240 VAC.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can the NPTU3000-O-NS support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 2700 VA \/ 2430 W continuous, powered from six internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What output does it provide?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"240\/120 VAC across one L6-30R, one L6-20R, one 6-20R duplex, and two 5-20R duplex receptacles.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232 and USB ports are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max LT UPS 3000VA 208\/240VAC (NPTU3000-O-NS)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817210088,"sku":"NPTU3000-O-NS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-lt-1_10k_e5268bf2-5165-4eb0-9609-bf47212fcd8c.png?v=1784386993"},{"product_id":"nxt-power-integrity-max-ups-2200va-nptu2200-ho-n","title":"NXT Power Integrity Max UPS 2200VA — Isolated Online Double-Conversion Hardwired UPS (NPTU2200-HO-N)","description":"\u003ch2\u003eNXT Power Integrity Max UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max UPS (NPTU2200-HO-N)\u003c\/strong\u003e delivers 2200 VA \/ 2200 W of isolated, online double-conversion power for hardwired facility installations. An IGBT rectifier and inverter regenerate clean output continuously through an internal isolation transformer. A manual bypass allows service without dropping the connected load.\u003c\/p\u003e\n\u003cp\u003eThis is a hardwired unit: 208 VAC input and a 240\/208\/120 VAC output are both terminated by an electrician at install. No plug or wall outlet is involved. RS-232, USB, and DB-9 dry contacts cover local monitoring, with an internal SNMP adapter available for network alerts.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and NXT Power's three-year warranty cover components and internal batteries. Sixteen internal VRLA batteries form the 192 VDC bus, sized for a short, clean ride-through rather than extended standby runtime.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS), hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU2200-HO-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion true sine wave output, IGBT rectifier and inverter, internal isolation transformer, manual bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e2200 VA \/ 2200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208 VAC nominal (200\/208\/220\/230\/240 VAC range, 176–275 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eHardwired (no plug); electrician-terminated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e240 \/ 208 \/ 120 VAC, hardwired multi-tap\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±1.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥91.0%; DC-AC ≥88.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManual Bypass\u003c\/td\u003e\n\u003ctd\u003eIncluded; transformer voltage regulation 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 16 (192 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 23 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB, DB-9 dry contacts; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage −15 to 55 °C, transit −15 to 60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤55 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e742 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e28.4 × 11.8 × 32.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 276 lb (125 kg); Shipping 342 lb (155 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, IEC 62040-1, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU2200-HO-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max UPS, hardwired, 208 VAC in \/ 240-208-120 VAC out\u003c\/td\u003e\n\u003ctd\u003e2200 VA \/ 2200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed more capacity? The NPTU4200-HO-N, NPTU6000-HO-N, and NPTU10.0-HO-N scale up to 4200 W, 5400 W, and 9000 W in the same hardwired Max chassis family.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Hardwired Facility UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a hardwired Max UPS is a facility decision, not a plug-in one. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined facility load; the NPTU2200-HO-N supports up to 2200 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, with a manual bypass for service.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits facility instrument and IT loads that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, DB-9 dry contacts, and an optional SNMP adapter support monitored, networked shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm 208 VAC hardwired facility distribution; an electrician must terminate the connection, as there is no plug.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eFacility-scale instrument and IT loads that exceed a Max LT unit's capacity fit the NPTU2200-HO-N's 2200 W rating. Equipment rooms consolidating multiple instrument racks, imaging suites, and small data closets all run on continuously isolated, regenerated power. Manual bypass keeps that load powered during scheduled UPS service.\u003c\/p\u003e\n\u003cp\u003eFacilities already wired for 208 VAC distribution are the natural fit, since this model has no plug and connects directly to a dedicated circuit. An electrical contractor should size and terminate the hardwired connection as part of installation.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU4200-HO-N — steps up to 4200 W in the same hardwired Max chassis family.\u003c\/li\u003e\n  \u003cli\u003eNPTU6000-HO-N and NPTU10.0-HO-N — 5400 W and 9000 W models for the largest facility loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFacility-scale, sample-critical loads this hardwired UPS class conditions and bridges through outages:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/ultra-low-temperature-freezers\"\u003eUltra-Low Temperature Freezers\u003c\/a\u003e — shield -80 °C sample storage from surges, sags, and brief outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/vnhoetby\/integrity-max-user-manual-revision-b-02-03-21.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIntegrity Max User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU2200-HO-N ships as a hardwired double-conversion UPS with internal batteries installed; a licensed electrician terminates the input and output connections. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your facility.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NPTU2200-HO-N plug into a wall outlet?\u003c\/strong\u003e\u003cbr\u003eNo. It's a hardwired unit; a licensed electrician terminates both the 208 VAC input and the 240\/208\/120 VAC output at install.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does double conversion with manual bypass mean?\u003c\/strong\u003e\u003cbr\u003eOutput is continuously regenerated from an isolated DC bus, and the manual bypass lets a technician service the unit without dropping the load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can it support?\u003c\/strong\u003e\u003cbr\u003eUp to 2200 VA \/ 2200 W continuous, powered from sixteen internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232, USB, and DB-9 dry contacts are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max UPS 2200VA (NPTU2200-HO-N)\",\n  \"sku\": \"NPTU2200-HO-N\",\n  \"mpn\": \"NPTU2200-HO-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 2200 VA \/ 2200 W hardwired UPS with true sine wave output, internal isolation transformer, and manual bypass for facility-scale loads. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-2200va-nptu2200-ho-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max UPS 4200VA (NPTU4200-HO-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-4200va-nptu4200-ho-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the NPTU2200-HO-N plug into a wall outlet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. It's a hardwired unit; a licensed electrician terminates both the 208 VAC input and the 240\/208\/120 VAC output at install.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does double conversion with manual bypass mean?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Output is continuously regenerated from an isolated DC bus, and the manual bypass lets a technician service the unit without dropping the load.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can it support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 2200 VA \/ 2200 W continuous, powered from sixteen internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232, USB, and DB-9 dry contacts are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max UPS 2200VA (NPTU2200-HO-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817242856,"sku":"NPTU2200-HO-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-max_0000_integrity-max-2-10-kvamax-front.png?v=1784386999"},{"product_id":"nxt-power-integrity-max-ups-4200va-nptu4200-ho-n","title":"NXT Power Integrity Max UPS 4200VA — Isolated Online Double-Conversion Hardwired UPS (NPTU4200-HO-N)","description":"\u003ch2\u003eNXT Power Integrity Max UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max UPS (NPTU4200-HO-N)\u003c\/strong\u003e supplies 4200 VA \/ 4200 W of isolated, online double-conversion power for larger hardwired facility installs. This IGBT rectifier-inverter pair and internal isolation transformer regenerate output continuously. A manual bypass allows servicing without interrupting the connected load.\u003c\/p\u003e\n\u003cp\u003eInput is hardwired at 208 VAC; output delivers a hardwired 240\/208\/120 VAC tap set sized by an electrician. There's no plug or outlet on this model. RS-232, USB, and DB-9 dry contacts handle local monitoring, with an internal SNMP adapter optional for network alerts.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and a three-year NXT Power warranty cover components and internal batteries. The same 192 VDC, sixteen-battery bus delivers a short, clean ride-through at this higher power level.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS), hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU4200-HO-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion true sine wave output, IGBT rectifier and inverter, internal isolation transformer, manual bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e4200 VA \/ 4200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208 VAC nominal (200\/208\/220\/230\/240 VAC range, 176–275 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eHardwired (no plug); electrician-terminated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e26 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e240 \/ 208 \/ 120 VAC, hardwired multi-tap\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±1.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥91.0%; DC-AC ≥88.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManual Bypass\u003c\/td\u003e\n\u003ctd\u003eIncluded; transformer voltage regulation 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 16 (192 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 8 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB, DB-9 dry contacts; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage −15 to 55 °C, transit −15 to 60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤55 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e1417 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e28.4 × 11.8 × 32.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 276 lb (125 kg); Shipping 342 lb (155 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, IEC 62040-1, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU4200-HO-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max UPS, hardwired, 208 VAC in \/ 240-208-120 VAC out\u003c\/td\u003e\n\u003ctd\u003e4200 VA \/ 4200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a different capacity? The NPTU2200-HO-N covers 2200 W, while the NPTU6000-HO-N and NPTU10.0-HO-N scale up to 5400 W and 9000 W.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Hardwired Facility UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a hardwired Max UPS is a facility decision, not a plug-in one. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined facility load; the NPTU4200-HO-N supports up to 4200 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, with a manual bypass for service.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits facility instrument and IT loads that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, DB-9 dry contacts, and an optional SNMP adapter support monitored, networked shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm 208 VAC hardwired facility distribution sized for 26 A; an electrician must terminate the connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eLarger equipment rooms and multi-rack instrument suites that exceed the NPTU2200-HO-N's capacity fit the NPTU4200-HO-N's 4200 W rating. Consolidated imaging, diagnostic, and IT infrastructure running on a shared hardwired feed benefits from continuously isolated, regenerated power. Manual bypass keeps that infrastructure live during scheduled maintenance.\u003c\/p\u003e\n\u003cp\u003eFacilities with dedicated 208 VAC distribution built for heavier equipment loads are the intended fit. No wall outlet or portable cord is involved at this capacity tier, and a licensed electrician must terminate the hardwired connection.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU2200-HO-N — the 2200 W entry point in the same hardwired Max chassis family.\u003c\/li\u003e\n  \u003cli\u003eNPTU6000-HO-N and NPTU10.0-HO-N — 5400 W and 9000 W models for the largest facility loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFacility-scale, sample-critical loads this hardwired UPS class conditions and bridges through outages:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/ultra-low-temperature-freezers\"\u003eUltra-Low Temperature Freezers\u003c\/a\u003e — shield -80 °C sample storage from surges, sags, and brief outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/vnhoetby\/integrity-max-user-manual-revision-b-02-03-21.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIntegrity Max User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU4200-HO-N ships as a hardwired double-conversion UPS with internal batteries installed; a licensed electrician terminates the input and output connections. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your facility.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NPTU4200-HO-N plug into a wall outlet?\u003c\/strong\u003e\u003cbr\u003eNo. It's a hardwired unit; a licensed electrician terminates both the 208 VAC input and the 240\/208\/120 VAC output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can it support?\u003c\/strong\u003e\u003cbr\u003eUp to 4200 VA \/ 4200 W continuous, powered from sixteen internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the manual bypass do?\u003c\/strong\u003e\u003cbr\u003eIt routes power around the UPS electronics during service, keeping the connected load powered without interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232, USB, and DB-9 dry contacts are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max UPS 4200VA (NPTU4200-HO-N)\",\n  \"sku\": \"NPTU4200-HO-N\",\n  \"mpn\": \"NPTU4200-HO-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 4200 VA \/ 4200 W hardwired UPS with true sine wave output, internal isolation transformer, and manual bypass for larger facility loads. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-4200va-nptu4200-ho-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max UPS 6000VA (NPTU6000-HO-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-6000va-nptu6000-ho-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the NPTU4200-HO-N plug into a wall outlet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. It's a hardwired unit; a licensed electrician terminates both the 208 VAC input and the 240\/208\/120 VAC output.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can it support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 4200 VA \/ 4200 W continuous, powered from sixteen internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does the manual bypass do?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It routes power around the UPS electronics during service, keeping the connected load powered without interruption.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232, USB, and DB-9 dry contacts are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max UPS 4200VA (NPTU4200-HO-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817308392,"sku":"NPTU4200-HO-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-max_0000_integrity-max-2-10-kvamax-front_b0578af8-c49f-40b0-9fcb-31fb24393b93.png?v=1784387004"},{"product_id":"nxt-power-integrity-max-ups-6000va-nptu6000-ho-n","title":"NXT Power Integrity Max UPS 6000VA — Isolated Online Double-Conversion Hardwired UPS (NPTU6000-HO-N)","description":"\u003ch2\u003eNXT Power Integrity Max UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max UPS (NPTU6000-HO-N)\u003c\/strong\u003e delivers 6000 VA \/ 5400 W of isolated, online double-conversion power for demanding hardwired facility installs. An IGBT rectifier and inverter regenerate output continuously through an internal isolation transformer. A manual bypass keeps the load powered during service.\u003c\/p\u003e\n\u003cp\u003eThe 208 VAC input and 240\/208\/120 VAC output both connect hardwired, terminated by an electrician at install. This model has no plug. RS-232, USB, and DB-9 dry contacts cover local monitoring, and an internal SNMP adapter is available for network alerts.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and a three-year NXT Power warranty cover components and internal batteries. Sixteen internal VRLA batteries form the 192 VDC bus behind a unit rated for 36 A of continuous input current.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS), hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU6000-HO-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion true sine wave output, IGBT rectifier and inverter, internal isolation transformer, manual bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e6000 VA \/ 5400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208 VAC nominal (200\/208\/220\/230\/240 VAC range, 176–275 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eHardwired (no plug); electrician-terminated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e36 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e240 \/ 208 \/ 120 VAC, hardwired multi-tap\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±1.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥91.0%; DC-AC ≥88.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManual Bypass\u003c\/td\u003e\n\u003ctd\u003eIncluded; transformer voltage regulation 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 16 (192 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 5 minutes at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB, DB-9 dry contacts; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (storage −15 to 55 °C, transit −15 to 60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤55 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e1822 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e28.4 × 11.8 × 32.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 276 lb (125 kg); Shipping 342 lb (155 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, IEC 62040-1, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU6000-HO-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max UPS, hardwired, 208 VAC in \/ 240-208-120 VAC out\u003c\/td\u003e\n\u003ctd\u003e6000 VA \/ 5400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a different capacity? The NPTU2200-HO-N and NPTU4200-HO-N cover 2200 W and 4200 W, while the NPTU10.0-HO-N scales up to 9000 W.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Hardwired Facility UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a hardwired Max UPS is a facility decision, not a plug-in one. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined facility load; the NPTU6000-HO-N supports up to 5400 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, with a manual bypass for service.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits facility instrument and IT loads that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, DB-9 dry contacts, and an optional SNMP adapter support monitored, networked shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm 208 VAC hardwired facility distribution sized for 36 A; an electrician must terminate the connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eThe largest consolidated equipment rooms in a typical lab or clinical facility fit the NPTU6000-HO-N's 5400 W rating. Multi-rack instrument suites, imaging clusters, and shared IT infrastructure all run on continuously isolated, regenerated power. Manual bypass matters most at this scale, where scheduled maintenance can't afford to drop the load.\u003c\/p\u003e\n\u003cp\u003eFacilities with dedicated 208 VAC distribution engineered for heavy, continuous draw are the intended fit. Installation requires a licensed electrician to terminate both input and output; there is no wall outlet at this capacity tier.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU2200-HO-N and NPTU4200-HO-N — 2200 W and 4200 W options in the same hardwired Max chassis family.\u003c\/li\u003e\n  \u003cli\u003eNPTU10.0-HO-N — the 9000 W model at the top of the Max line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFacility-scale, sample-critical loads this hardwired UPS class conditions and bridges through outages:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/ultra-low-temperature-freezers\"\u003eUltra-Low Temperature Freezers\u003c\/a\u003e — shield -80 °C sample storage from surges, sags, and brief outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/vnhoetby\/integrity-max-user-manual-revision-b-02-03-21.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIntegrity Max User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU6000-HO-N ships as a hardwired double-conversion UPS with internal batteries installed; a licensed electrician terminates the input and output connections. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your facility.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NPTU6000-HO-N plug into a wall outlet?\u003c\/strong\u003e\u003cbr\u003eNo. It's a hardwired unit; a licensed electrician terminates both the 208 VAC input and the 240\/208\/120 VAC output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can it support?\u003c\/strong\u003e\u003cbr\u003eUp to 6000 VA \/ 5400 W continuous, powered from sixteen internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the manual bypass do?\u003c\/strong\u003e\u003cbr\u003eIt routes power around the UPS electronics during service, keeping the connected load powered without interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232, USB, and DB-9 dry contacts are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max UPS 6000VA (NPTU6000-HO-N)\",\n  \"sku\": \"NPTU6000-HO-N\",\n  \"mpn\": \"NPTU6000-HO-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 6000 VA \/ 5400 W hardwired UPS with true sine wave output, internal isolation transformer, and manual bypass for the largest consolidated equipment rooms. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-6000va-nptu6000-ho-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max UPS 10kVA (NPTU10.0-HO-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-10000va-nptu10-0-ho-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the NPTU6000-HO-N plug into a wall outlet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. It's a hardwired unit; a licensed electrician terminates both the 208 VAC input and the 240\/208\/120 VAC output.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can it support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 6000 VA \/ 5400 W continuous, powered from sixteen internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does the manual bypass do?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It routes power around the UPS electronics during service, keeping the connected load powered without interruption.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232, USB, and DB-9 dry contacts are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max UPS 6000VA (NPTU6000-HO-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817341160,"sku":"NPTU6000-HO-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-max_0000_integrity-max-2-10-kvamax-front_67946bcd-6d2e-4694-adb9-1232bc0d8391.png?v=1784387008"},{"product_id":"nxt-power-integrity-max-ups-10000va-nptu10-0-ho-n","title":"NXT Power Integrity Max UPS 10kVA — Isolated Online Double-Conversion Hardwired UPS (NPTU10.0-HO-N)","description":"\u003ch2\u003eNXT Power Integrity Max UPS Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNXT Power Integrity Max UPS (NPTU10.0-HO-N)\u003c\/strong\u003e tops the Max line at 10000 VA \/ 9000 W of isolated, online double-conversion power. It's built for the heaviest hardwired facility installs. This IGBT rectifier-inverter architecture and internal isolation transformer regenerate output continuously, with a manual bypass for uninterrupted service.\u003c\/p\u003e\n\u003cp\u003eInput connects hardwired at 208 VAC, rated for 57 A continuous. Output delivers a hardwired 240\/208\/120 VAC tap set; there is no plug on this model. RS-232, USB, and DB-9 dry contacts handle local monitoring, with an internal SNMP adapter available for network alerts.\u003c\/p\u003e\n\u003cp\u003eUL1778 listing and a three-year NXT Power warranty cover components and internal batteries. Sixteen internal VRLA batteries form the 192 VDC bus behind this higher-capacity unit.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion uninterruptible power supply (UPS), hardwired\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNPTU10.0-HO-N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion true sine wave output, IGBT rectifier and inverter, internal isolation transformer, manual bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd\u003e10000 VA \/ 9000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e208 VAC nominal (200\/208\/220\/230\/240 VAC range, 176–275 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Connection\u003c\/td\u003e\n\u003ctd\u003eHardwired (no plug); electrician-terminated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Rated Current\u003c\/td\u003e\n\u003ctd\u003e57 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e240 \/ 208 \/ 120 VAC, hardwired multi-tap\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd\u003e±1.0% of nominal (mains or battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eAC-DC-AC ≥91.0%; DC-AC ≥88.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManual Bypass\u003c\/td\u003e\n\u003ctd\u003eIncluded; transformer voltage regulation 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e12 V high-rate VRLA, flame retardant; Qty 16 (192 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 1 minute at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRecharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;8 hours to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-232, USB, DB-9 dry contacts; internal SNMP adapter optional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 40 °C (storage −25 to 55 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 90%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e≤55 dBA at 1 m from front\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e3037 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e28.4 × 11.8 × 29.1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eUnit 317 lb (144 kg); Shipping 391 lb (177 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSafety \/ EMC\u003c\/td\u003e\n\u003ctd\u003eUL1778, cUL to CSA 22.2 No. 107.3, IEC 62040-1, FCC Part 15J Class A, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C62.41 Cat. A \u0026amp; B (6000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year, components and internal batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAvailable Sizes and Configurations\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNPTU10.0-HO-N\u003c\/td\u003e\n\u003ctd\u003eIntegrity Max UPS, hardwired, 208 VAC in \/ 240-208-120 VAC out\u003c\/td\u003e\n\u003ctd\u003e10000 VA \/ 9000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a smaller footprint? The NPTU2200-HO-N, NPTU4200-HO-N, and NPTU6000-HO-N cover 2200 W, 4200 W, and 5400 W in the same hardwired Max chassis family.\u003c\/p\u003e\n\u003ch2\u003eHow to Choose the Right Hardwired Facility UPS\u003c\/h2\u003e\n\u003cp\u003eSizing a hardwired Max UPS is a facility decision, not a plug-in one. Weigh these axes before you spec a unit:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity headroom\u003c\/strong\u003e — size above the combined facility load; the NPTU10.0-HO-N supports up to 9000 W continuous.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation vs. standard backup\u003c\/strong\u003e — continuous double-conversion output stays isolated and regenerated at all times, with a manual bypass for service.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWaveform\u003c\/strong\u003e — true sine wave output suits facility-wide instrument and IT loads that reject stepped waveforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShutdown \u0026amp; communication\u003c\/strong\u003e — RS-232, USB, DB-9 dry contacts, and an optional SNMP adapter support monitored, networked shutdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite power\u003c\/strong\u003e — confirm dedicated 208 VAC hardwired distribution sized for 57 A; an electrician must terminate the connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cp\u003eFacility-wide power protection for a full lab building or clinical wing fits the NPTU10.0-HO-N's 9000 W rating. Consolidated instrument suites, imaging departments, and central IT infrastructure sharing one hardwired feed all run on continuously isolated, regenerated power. Manual bypass is essential at this scale, keeping an entire facility segment live during scheduled maintenance.\u003c\/p\u003e\n\u003cp\u003eOnly facilities with dedicated, heavy-gauge 208 VAC distribution should spec this model. There is no wall outlet or portable configuration at this capacity, and a licensed electrician must terminate both hardwired connections.\u003c\/p\u003e\n\u003ch2\u003eRelated Products and Accessories\u003c\/h2\u003e\n\u003cp\u003eExplore the full NXT Power line for other capacities and configurations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/nxt-power\"\u003eNXT Power Integrity Series UPS\u003c\/a\u003e — desktop, standard, rack-tower, and Max models.\u003c\/li\u003e\n  \u003cli\u003eNPTU2200-HO-N, NPTU4200-HO-N, and NPTU6000-HO-N — 2200 W, 4200 W, and 5400 W options in the same hardwired Max chassis family.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFacility-scale, sample-critical loads this hardwired UPS class conditions and bridges through outages:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/ultra-low-temperature-freezers\"\u003eUltra-Low Temperature Freezers\u003c\/a\u003e — shield -80 °C sample storage from surges, sags, and brief outages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/low-temperature-freezers\"\u003eLow-Temperature Freezers\u003c\/a\u003e — conditioned power and ride-through for -40 to -25 °C storage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/collections\/freeze-dryers\"\u003eFreeze Dryers\u003c\/a\u003e — protect multi-day lyophilization runs and vacuum integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Documentation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/www.nxtpower.com\/media\/vnhoetby\/integrity-max-user-manual-revision-b-02-03-21.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIntegrity Max User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering\u003c\/h2\u003e\n\u003cp\u003eEach NPTU10.0-HO-N ships as a hardwired double-conversion UPS with internal batteries installed; a licensed electrician terminates the input and output connections. LabSupplies.com is an authorized NXT Power dealer, ships from US inventory, and provides direct manufacturer service and support. Contact us to confirm the right configuration for your facility.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NPTU10.0-HO-N plug into a wall outlet?\u003c\/strong\u003e\u003cbr\u003eNo. It's a hardwired unit; a licensed electrician terminates both the 208 VAC input and the 240\/208\/120 VAC output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat load can it support?\u003c\/strong\u003e\u003cbr\u003eUp to 10000 VA \/ 9000 W continuous, powered from sixteen internal 12 V VRLA batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the manual bypass do?\u003c\/strong\u003e\u003cbr\u003eIt routes power around the UPS electronics during service, keeping the connected load powered without interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eRS-232, USB, and DB-9 dry contacts are standard, with an internal SNMP adapter available as an option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long is the warranty?\u003c\/strong\u003e\u003cbr\u003eThree years, covering components and the internal batteries from the date of shipment.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"NXT Power Integrity Max UPS 10kVA (NPTU10.0-HO-N)\",\n  \"sku\": \"NPTU10.0-HO-N\",\n  \"mpn\": \"NPTU10.0-HO-N\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"NXT Power\"\n  },\n  \"description\": \"Isolated, online double-conversion 10000 VA \/ 9000 W hardwired UPS with true sine wave output, internal isolation transformer, and manual bypass for facility-wide power protection. UL1778 listed, 3-year warranty.\",\n  \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-10000va-nptu10-0-ho-n\",\n  \"category\": \"Uninterruptible Power Supply (UPS)\",\n  \"isRelatedTo\": {\n    \"@type\": \"Product\",\n    \"name\": \"NXT Power Integrity Max UPS 6000VA (NPTU6000-HO-N)\",\n    \"url\": \"https:\/\/labsupplies.com\/products\/nxt-power-integrity-max-ups-6000va-nptu6000-ho-n\"\n  },\n  \"dateModified\": \"2026-07-15\"\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the NPTU10.0-HO-N plug into a wall outlet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. It's a hardwired unit; a licensed electrician terminates both the 208 VAC input and the 240\/208\/120 VAC output.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What load can it support?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Up to 10000 VA \/ 9000 W continuous, powered from sixteen internal 12 V VRLA batteries.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What does the manual bypass do?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It routes power around the UPS electronics during service, keeping the connected load powered without interruption.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does it support remote monitoring?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"RS-232, USB, and DB-9 dry contacts are standard, with an internal SNMP adapter available as an option.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long is the warranty?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Three years, covering components and the internal batteries from the date of shipment.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BreadcrumbList\",\n  \"itemListElement\": [\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 1,\n      \"name\": \"Home\",\n      \"item\": \"https:\/\/labsupplies.com\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 2,\n      \"name\": \"NXT Power UPS\",\n      \"item\": \"https:\/\/labsupplies.com\/collections\/nxt-power\"\n    },\n    {\n      \"@type\": \"ListItem\",\n      \"position\": 3,\n      \"name\": \"NXT Power Integrity Max UPS 10kVA (NPTU10.0-HO-N)\"\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"NXT Power","offers":[{"title":"Default Title","offer_id":48771817373928,"sku":"NPTU10.0-HO-N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/integrity-max_0000_integrity-max-2-10-kvamax-front_7be6dbe9-6204-4509-b654-ef1c0c23237a.png?v=1784387013"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/collections\/NXT_POWER_LOGO_271dd40e-f4f0-4b8c-a67b-6b3f636d6c9a.jpg?v=1783609555","url":"https:\/\/labsupplies.com\/collections\/nxt-power.oembed","provider":"LabSupplies.com","version":"1.0","type":"link"}