{"title":"Heathrow Scientific Thermometers","description":null,"products":[{"product_id":"veegee-thermometer-fep-armor-f","title":"VEE GEE Scientific FEP Encapsulated Armored Glass Thermometer - Fahrenheit - Mercury-Free Blue Liquid","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eWhen a glass thermometer breaks in a laboratory environment, two hazards occur simultaneously: sharp glass fragments and chemical fill contamination. The VEE GEE Scientific FEP Encapsulated Armored Glass Thermometer addresses both in a single instrument. The nickel-plated brass armor absorbs impact and protects the thermometer from rough handling and shock. The FEP (fluorinated ethylene propylene) encapsulation layer surrounds the glass — if the thermometer breaks despite the armor, the FEP coating contains the glass fragments and mercury-free blue liquid fill, preventing injury and contamination of the work environment.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFilled with VEE GEE's Safety Blue organic liquid — biodegradable, non-toxic, and mercury-free — these thermometers deliver the accuracy and reliability of traditional liquid-in-glass instruments without the environmental and safety liabilities of mercury. Available in Fahrenheit (°F) scales across multiple temperature ranges, in Total and Partial Immersion configurations. Each thermometer is individually serialized for calibration traceability.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eDual Protection: FEP Encapsulation + Nickel-Plated Brass Armor:\u003c\/strong\u003e The outer brass armor absorbs mechanical impact and shock during handling and transport. The inner FEP encapsulation layer contains glass and liquid fill in the event of breakage — providing two independent safety barriers in one thermometer.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMercury-Free Safety Blue Fill:\u003c\/strong\u003e Organic, biodegradable, and non-toxic liquid fill delivers performance equivalent to mercury-filled thermometers without hazardous material liabilities — compliant with mercury-free lab policies and disposal regulations.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIndividually Serialized:\u003c\/strong\u003e Each thermometer carries a unique serial number for calibration tracking, chain-of-custody documentation, and audit trail compliance in GLP, ISO, and regulated research environments.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eBorosilicate Glass Construction:\u003c\/strong\u003e Premium borosilicate glass provides thermal expansion stability and chemical resistance — maintains accurate readings across the full temperature range without glass deformation.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePermanently Etched Scale:\u003c\/strong\u003e Temperature graduations are etched directly into the glass and filled with white enamel — the scale cannot wear away, smear, or peel during cleaning or repeated use.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSafety Blue Fill Against White Background:\u003c\/strong\u003e High-contrast blue liquid column against a white enamel background provides excellent readability in typical lab lighting conditions without magnification.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTotal and Partial Immersion Options:\u003c\/strong\u003e Choose Total Immersion for highest accuracy when the entire thermometer is submerged; choose Partial Immersion for applications where only part of the thermometer enters the measured medium.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMultiple Temperature Ranges:\u003c\/strong\u003e Available across 4 temperature ranges in Fahrenheit (°F) scale — select the range that best matches your specific application requirements.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications by Temperature Range\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTemperature Range\u003c\/th\u003e\n\u003cth\u003eImmersion Type\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-30 to 120°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80701E-A (Total) \/ 80901E-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-4 to 230°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80702E-A (Total) \/ 80902E-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0 to 300°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80703E-A (Total) \/ 80903E-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e30 to 220°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e16 in (40.6 cm)\u003c\/td\u003e\n\u003ctd\u003e80704E-A (Total) \/ 80904E-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eVEE GEE Thermometer Protection Level Guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eLevel\u003c\/th\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003cth\u003eBreakage Containment\u003c\/th\u003e\n\u003cth\u003eImpact Protection\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP Encapsulated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP sleeve\u003c\/td\u003e\n\u003ctd\u003eYes — glass and fill contained\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNickel-plated brass armor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP + Armored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP + Brass Armor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLaboratory water bath and heating block temperature verification where liquid-in-glass accuracy and mercury-free certification are both required\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFood and beverage processing where temperature compliance monitoring requires traceable, serialized thermometers meeting mercury-free standards\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eEnvironmental monitoring, wastewater treatment, and field sampling where general-purpose Fahrenheit (°F) measurement is required with minimal calibration overhead\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eUniversity teaching labs requiring affordable, accurate thermometers with serialized traceability for student experiment documentation\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is Safety Blue fill and is it safe if the thermometer breaks?\u003cbr\u003e\u003c\/strong\u003eSafety Blue is VEE GEE's organic, biodegradable blue liquid that replaces mercury in liquid-in-glass thermometers. It is non-toxic and non-hazardous — unlike mercury, a broken Safety Blue thermometer does not require mercury spill response procedures. The liquid is safe to handle and the instrument can be disposed of in standard laboratory glass waste rather than as hazardous waste.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is the difference between Total and Partial Immersion?\u003cbr\u003e\u003c\/strong\u003eTotal Immersion thermometers are calibrated for use when the entire thermometer (bulb and liquid column) is submerged in the measured medium — this provides maximum accuracy. Partial Immersion thermometers are calibrated for use when only the lower portion (typically 3 inches) is immersed, with the upper portion in air. Choose Total for water baths and enclosed temperature measurement; Partial for applications where full immersion is not possible.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat does \"serialized\" mean for these thermometers?\u003cbr\u003e\u003c\/strong\u003eEach thermometer is individually marked with a unique serial number during manufacturing. The serial number ties the instrument to production lot records and enables calibration documentation — important for GLP compliance, ISO 17025 requirements, and any laboratory quality system requiring instrument-level traceability.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThis listing shows FEP Encapsulated + Armored protection. What other options are available?\u003cbr\u003e\u003c\/strong\u003eThis is the highest protection level. No upgrade available.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHow do I select the right temperature range?\u003cbr\u003e\u003c\/strong\u003eChoose a range where your target temperature falls in the middle third of the scale — this provides the most accurate readings and the longest usable column length for interpolation. Avoid using thermometers at the extreme ends of their rated range, where accuracy and resolution are reduced.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eVEE GEE Scientific manufactures these thermometers from premium borosilicate glass with permanently etched scales and individually serialized markings. Each thermometer is filled with Safety Blue organic liquid verified for consistent performance across the full rated temperature range. FEP encapsulation is applied and tested for complete glass and liquid containment integrity. Nickel-plated brass armor is fitted and inspected for secure engagement and impact resistance. VEE GEE backs these thermometers with a 1-year warranty.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAs an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"VEE GEE Scientific","offers":[{"title":"Total Immersion \/ -30 to 120°F","offer_id":48075653415144,"sku":"80701E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -30 to 120°F","offer_id":48075653447912,"sku":"80901E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ -4 to 230°F","offer_id":48075653480680,"sku":"80702E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -4 to 230°F","offer_id":48075653513448,"sku":"80902E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ 0 to 300°F","offer_id":48075653546216,"sku":"80703E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ 0 to 300°F","offer_id":48075653578984,"sku":"80903E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ 30 to 220°F (16in)","offer_id":48075653611752,"sku":"80704E-A","price":95.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ 30 to 220°F (16in)","offer_id":48075653644520,"sku":"80904E-A","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/unnamed_eef4af72-d567-4d34-8c62-8a85865b6276.jpg?v=1771817217"},{"product_id":"veegee-thermometer-fep-armor-c","title":"VEE GEE Scientific FEP Encapsulated Armored Glass Thermometer - Celsius - Mercury-Free Blue Liquid","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eWhen a glass thermometer breaks in a laboratory environment, two hazards occur simultaneously: sharp glass fragments and chemical fill contamination. The VEE GEE Scientific FEP Encapsulated Armored Glass Thermometer addresses both in a single instrument. The nickel-plated brass armor absorbs impact and protects the thermometer from rough handling and shock. The FEP (fluorinated ethylene propylene) encapsulation layer surrounds the glass — if the thermometer breaks despite the armor, the FEP coating contains the glass fragments and mercury-free blue liquid fill, preventing injury and contamination of the work environment.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFilled with VEE GEE's Safety Blue organic liquid — biodegradable, non-toxic, and mercury-free — these thermometers deliver the accuracy and reliability of traditional liquid-in-glass instruments without the environmental and safety liabilities of mercury. Available in Celsius (°C) scales across multiple temperature ranges, in Total and Partial Immersion configurations. Each thermometer is individually serialized for calibration traceability.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eDual Protection: FEP Encapsulation + Nickel-Plated Brass Armor:\u003c\/strong\u003e The outer brass armor absorbs mechanical impact and shock during handling and transport. The inner FEP encapsulation layer contains glass and liquid fill in the event of breakage — providing two independent safety barriers in one thermometer.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMercury-Free Safety Blue Fill:\u003c\/strong\u003e Organic, biodegradable, and non-toxic liquid fill delivers performance equivalent to mercury-filled thermometers without hazardous material liabilities — compliant with mercury-free lab policies and disposal regulations.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIndividually Serialized:\u003c\/strong\u003e Each thermometer carries a unique serial number for calibration tracking, chain-of-custody documentation, and audit trail compliance in GLP, ISO, and regulated research environments.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eBorosilicate Glass Construction:\u003c\/strong\u003e Premium borosilicate glass provides thermal expansion stability and chemical resistance — maintains accurate readings across the full temperature range without glass deformation.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePermanently Etched Scale:\u003c\/strong\u003e Temperature graduations are etched directly into the glass and filled with white enamel — the scale cannot wear away, smear, or peel during cleaning or repeated use.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSafety Blue Fill Against White Background:\u003c\/strong\u003e High-contrast blue liquid column against a white enamel background provides excellent readability in typical lab lighting conditions without magnification.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTotal and Partial Immersion Options:\u003c\/strong\u003e Choose Total Immersion for highest accuracy when the entire thermometer is submerged; choose Partial Immersion for applications where only part of the thermometer enters the measured medium.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMultiple Temperature Ranges:\u003c\/strong\u003e Available across 3 temperature ranges in Celsius (°C) scale — select the range that best matches your specific application requirements.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications by Temperature Range\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTemperature Range\u003c\/th\u003e\n\u003cth\u003eImmersion Type\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-35 to 50°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80706E-A (Total) \/ 80906E-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-20 to 110°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80707E-A (Total) \/ 80907E-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-20 to 150°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80708E-A (Total) \/ 80908E-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eVEE GEE Thermometer Protection Level Guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eLevel\u003c\/th\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003cth\u003eBreakage Containment\u003c\/th\u003e\n\u003cth\u003eImpact Protection\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP Encapsulated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP sleeve\u003c\/td\u003e\n\u003ctd\u003eYes — glass and fill contained\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNickel-plated brass armor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP + Armored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP + Brass Armor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLaboratory water bath and heating block temperature verification where liquid-in-glass accuracy and mercury-free certification are both required\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFood and beverage processing where temperature compliance monitoring requires traceable, serialized thermometers meeting mercury-free standards\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eEnvironmental monitoring, wastewater treatment, and field sampling where general-purpose Celsius (°C) measurement is required with minimal calibration overhead\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eUniversity teaching labs requiring affordable, accurate thermometers with serialized traceability for student experiment documentation\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is Safety Blue fill and is it safe if the thermometer breaks?\u003cbr\u003e\u003c\/strong\u003eSafety Blue is VEE GEE's organic, biodegradable blue liquid that replaces mercury in liquid-in-glass thermometers. It is non-toxic and non-hazardous — unlike mercury, a broken Safety Blue thermometer does not require mercury spill response procedures. The liquid is safe to handle and the instrument can be disposed of in standard laboratory glass waste rather than as hazardous waste.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is the difference between Total and Partial Immersion?\u003cbr\u003e\u003c\/strong\u003eTotal Immersion thermometers are calibrated for use when the entire thermometer (bulb and liquid column) is submerged in the measured medium — this provides maximum accuracy. Partial Immersion thermometers are calibrated for use when only the lower portion (typically 3 inches) is immersed, with the upper portion in air. Choose Total for water baths and enclosed temperature measurement; Partial for applications where full immersion is not possible.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat does \"serialized\" mean for these thermometers?\u003cbr\u003e\u003c\/strong\u003eEach thermometer is individually marked with a unique serial number during manufacturing. The serial number ties the instrument to production lot records and enables calibration documentation — important for GLP compliance, ISO 17025 requirements, and any laboratory quality system requiring instrument-level traceability.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThis listing shows FEP Encapsulated + Armored protection. What other options are available?\u003cbr\u003e\u003c\/strong\u003eThis is the highest protection level. No upgrade available.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHow do I select the right temperature range?\u003cbr\u003e\u003c\/strong\u003eChoose a range where your target temperature falls in the middle third of the scale — this provides the most accurate readings and the longest usable column length for interpolation. Avoid using thermometers at the extreme ends of their rated range, where accuracy and resolution are reduced.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eVEE GEE Scientific manufactures these thermometers from premium borosilicate glass with permanently etched scales and individually serialized markings. Each thermometer is filled with Safety Blue organic liquid verified for consistent performance across the full rated temperature range. FEP encapsulation is applied and tested for complete glass and liquid containment integrity. Nickel-plated brass armor is fitted and inspected for secure engagement and impact resistance. VEE GEE backs these thermometers with a 1-year warranty.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAs an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"VEE GEE Scientific","offers":[{"title":"Total Immersion \/ -35 to 50°C","offer_id":48075654136040,"sku":"80706E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -35 to 50°C","offer_id":48075654168808,"sku":"80906E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ -20 to 110°C","offer_id":48075654201576,"sku":"80707E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -20 to 110°C","offer_id":48075654234344,"sku":"80907E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ -20 to 150°C","offer_id":48075654267112,"sku":"80708E-A","price":77.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -20 to 150°C","offer_id":48075654299880,"sku":"80908E-A","price":77.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/unnamed_4e320a59-8496-4919-b3ef-8a70d2dc2546.jpg?v=1771817219"},{"product_id":"veegee-thermometer-armor-f","title":"VEE GEE Scientific Armored Glass Thermometer - Fahrenheit - Nickel-Plated Brass, Mercury-Free","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eGlass thermometers fail when dropped or struck — and in busy laboratory environments, rough handling is unavoidable. The VEE GEE Scientific Armored Glass Thermometer surrounds the borosilicate glass in nickel-plated brass armor that absorbs impact and shock during active use, protecting the instrument from the most common causes of thermometer failure without adding bulk that interferes with normal handling.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFilled with VEE GEE's mercury-free Safety Blue organic liquid, these individually serialized thermometers are built for laboratories, food and beverage processing, environmental monitoring, and general industrial use where durability and measurement traceability are both required. Available in Fahrenheit (°F) scale across multiple temperature ranges and immersion configurations.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eNickel-Plated Brass Armor:\u003c\/strong\u003e Full-length armor enclosure protects the glass thermometer from impact, shock, and rough handling — significantly extends service life in high-use laboratory and industrial environments.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMercury-Free Safety Blue Fill:\u003c\/strong\u003e Organic, biodegradable liquid fill performs equivalently to mercury across the full temperature range — no mercury disposal liability, no hazmat shipping restrictions.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIndividually Serialized:\u003c\/strong\u003e Unique serial number on each thermometer supports calibration records, instrument tracking, and regulatory audit documentation for GLP and ISO-compliant lab operations.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eBorosilicate Glass:\u003c\/strong\u003e Premium glass construction with permanently etched temperature scale — graduations cannot wear, peel, or smear through repeated use and cleaning cycles.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSafety Blue Against White Background:\u003c\/strong\u003e High-contrast blue liquid column on white enamel background — easy reading in standard lab lighting without magnification aids.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTotal and Partial Immersion Options:\u003c\/strong\u003e Total Immersion for maximum accuracy in fully submerged applications; Partial Immersion for surface or partial-contact temperature measurement.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMultiple Temperature Ranges:\u003c\/strong\u003e Available across 3 temperature ranges in Fahrenheit (°F) — select the range appropriate for your specific measurement application.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications by Temperature Range\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTemperature Range\u003c\/th\u003e\n\u003cth\u003eImmersion Type\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-30 to 120°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80701-A (Total) \/ 80901-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-4 to 230°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80702-A (Total) \/ 80902-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0 to 300°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80703-A (Total) \/ 80903-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eVEE GEE Thermometer Protection Level Guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eLevel\u003c\/th\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003cth\u003eBreakage Containment\u003c\/th\u003e\n\u003cth\u003eImpact Protection\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP Encapsulated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP sleeve\u003c\/td\u003e\n\u003ctd\u003eYes — glass and fill contained\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNickel-plated brass armor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP + Armored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP + Brass Armor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLaboratory water bath and heating block temperature verification where liquid-in-glass accuracy and mercury-free certification are both required\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFood and beverage processing where temperature compliance monitoring requires traceable, serialized thermometers meeting mercury-free standards\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eEnvironmental monitoring, wastewater treatment, and field sampling where general-purpose Fahrenheit (°F) measurement is required with minimal calibration overhead\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eUniversity teaching labs requiring affordable, accurate thermometers with serialized traceability for student experiment documentation\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is Safety Blue fill and is it safe if the thermometer breaks?\u003cbr\u003e\u003c\/strong\u003eSafety Blue is VEE GEE's organic, biodegradable blue liquid that replaces mercury in liquid-in-glass thermometers. It is non-toxic and non-hazardous — unlike mercury, a broken Safety Blue thermometer does not require mercury spill response procedures. The liquid is safe to handle and the instrument can be disposed of in standard laboratory glass waste rather than as hazardous waste.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is the difference between Total and Partial Immersion?\u003cbr\u003e\u003c\/strong\u003eTotal Immersion thermometers are calibrated for use when the entire thermometer (bulb and liquid column) is submerged in the measured medium — this provides maximum accuracy. Partial Immersion thermometers are calibrated for use when only the lower portion (typically 3 inches) is immersed, with the upper portion in air. Choose Total for water baths and enclosed temperature measurement; Partial for applications where full immersion is not possible.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat does \"serialized\" mean for these thermometers?\u003cbr\u003e\u003c\/strong\u003eEach thermometer is individually marked with a unique serial number during manufacturing. The serial number ties the instrument to production lot records and enables calibration documentation — important for GLP compliance, ISO 17025 requirements, and any laboratory quality system requiring instrument-level traceability.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThis listing shows Armored (no FEP) protection. What other options are available?\u003cbr\u003e\u003c\/strong\u003eFor containment of glass and fill on breakage, upgrade to the FEP Encapsulated + Armored version (80x01E-A \/ 80x06E-A series).\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHow do I select the right temperature range?\u003cbr\u003e\u003c\/strong\u003eChoose a range where your target temperature falls in the middle third of the scale — this provides the most accurate readings and the longest usable column length for interpolation. Avoid using thermometers at the extreme ends of their rated range, where accuracy and resolution are reduced.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eVEE GEE Scientific manufactures these thermometers from premium borosilicate glass with permanently etched scales and individually serialized markings. Each thermometer is filled with Safety Blue organic liquid verified for consistent performance across the full rated temperature range. Nickel-plated brass armor is fitted and inspected for secure engagement and impact resistance. VEE GEE backs these thermometers with a 1-year warranty.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAs an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"VEE GEE Scientific","offers":[{"title":"Total Immersion \/ -30 to 120°F","offer_id":48075654824168,"sku":"80701-A","price":45.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -30 to 120°F","offer_id":48075654856936,"sku":"80901-A","price":45.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ -4 to 230°F","offer_id":48075654889704,"sku":"80702-A","price":45.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -4 to 230°F","offer_id":48075654922472,"sku":"80902-A","price":45.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ 0 to 300°F","offer_id":48075654955240,"sku":"80703-A","price":45.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ 0 to 300°F","offer_id":48075654988008,"sku":"80903-A","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/unnamed_01c09c78-84e5-4c9f-803c-a62257f14b2b.jpg?v=1771817220"},{"product_id":"veegee-thermometer-armor-c","title":"VEE GEE Scientific Armored Glass Thermometer - Celsius - Nickel-Plated Brass, Mercury-Free","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eGlass thermometers fail when dropped or struck — and in busy laboratory environments, rough handling is unavoidable. The VEE GEE Scientific Armored Glass Thermometer surrounds the borosilicate glass in nickel-plated brass armor that absorbs impact and shock during active use, protecting the instrument from the most common causes of thermometer failure without adding bulk that interferes with normal handling.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFilled with VEE GEE's mercury-free Safety Blue organic liquid, these individually serialized thermometers are built for laboratories, food and beverage processing, environmental monitoring, and general industrial use where durability and measurement traceability are both required. Available in Celsius (°C) scale across multiple temperature ranges and immersion configurations.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eNickel-Plated Brass Armor:\u003c\/strong\u003e Full-length armor enclosure protects the glass thermometer from impact, shock, and rough handling — significantly extends service life in high-use laboratory and industrial environments.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMercury-Free Safety Blue Fill:\u003c\/strong\u003e Organic, biodegradable liquid fill performs equivalently to mercury across the full temperature range — no mercury disposal liability, no hazmat shipping restrictions.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIndividually Serialized:\u003c\/strong\u003e Unique serial number on each thermometer supports calibration records, instrument tracking, and regulatory audit documentation for GLP and ISO-compliant lab operations.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eBorosilicate Glass:\u003c\/strong\u003e Premium glass construction with permanently etched temperature scale — graduations cannot wear, peel, or smear through repeated use and cleaning cycles.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSafety Blue Against White Background:\u003c\/strong\u003e High-contrast blue liquid column on white enamel background — easy reading in standard lab lighting without magnification aids.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTotal and Partial Immersion Options:\u003c\/strong\u003e Total Immersion for maximum accuracy in fully submerged applications; Partial Immersion for surface or partial-contact temperature measurement.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMultiple Temperature Ranges:\u003c\/strong\u003e Available across 5 temperature ranges in Celsius (°C) — select the range appropriate for your specific measurement application.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications by Temperature Range\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTemperature Range\u003c\/th\u003e\n\u003cth\u003eImmersion Type\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-35 to 50°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80706-A (Total) \/ 80906-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-20 to 110°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80707-A (Total) \/ 80907-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-20 to 150°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80708-A (Total) \/ 80908-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20 to 200°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePartial only Immersion\u003c\/td\u003e\n\u003ctd\u003e2°C\u003c\/td\u003e\n\u003ctd\u003e16 in (40.6 cm)\u003c\/td\u003e\n\u003ctd\u003e— (Total) \/ 80905-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-10 to 250°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePartial only Immersion\u003c\/td\u003e\n\u003ctd\u003e2°C\u003c\/td\u003e\n\u003ctd\u003e15.4 in (39 cm)\u003c\/td\u003e\n\u003ctd\u003e— (Total) \/ 80910-A (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eVEE GEE Thermometer Protection Level Guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eLevel\u003c\/th\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003cth\u003eBreakage Containment\u003c\/th\u003e\n\u003cth\u003eImpact Protection\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP Encapsulated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP sleeve\u003c\/td\u003e\n\u003ctd\u003eYes — glass and fill contained\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNickel-plated brass armor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP + Armored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP + Brass Armor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLaboratory water bath and heating block temperature verification where liquid-in-glass accuracy and mercury-free certification are both required\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFood and beverage processing where temperature compliance monitoring requires traceable, serialized thermometers meeting mercury-free standards\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eEnvironmental monitoring, wastewater treatment, and field sampling where general-purpose Celsius (°C) measurement is required with minimal calibration overhead\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eUniversity teaching labs requiring affordable, accurate thermometers with serialized traceability for student experiment documentation\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is Safety Blue fill and is it safe if the thermometer breaks?\u003cbr\u003e\u003c\/strong\u003eSafety Blue is VEE GEE's organic, biodegradable blue liquid that replaces mercury in liquid-in-glass thermometers. It is non-toxic and non-hazardous — unlike mercury, a broken Safety Blue thermometer does not require mercury spill response procedures. The liquid is safe to handle and the instrument can be disposed of in standard laboratory glass waste rather than as hazardous waste.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is the difference between Total and Partial Immersion?\u003cbr\u003e\u003c\/strong\u003eTotal Immersion thermometers are calibrated for use when the entire thermometer (bulb and liquid column) is submerged in the measured medium — this provides maximum accuracy. Partial Immersion thermometers are calibrated for use when only the lower portion (typically 3 inches) is immersed, with the upper portion in air. Choose Total for water baths and enclosed temperature measurement; Partial for applications where full immersion is not possible.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat does \"serialized\" mean for these thermometers?\u003cbr\u003e\u003c\/strong\u003eEach thermometer is individually marked with a unique serial number during manufacturing. The serial number ties the instrument to production lot records and enables calibration documentation — important for GLP compliance, ISO 17025 requirements, and any laboratory quality system requiring instrument-level traceability.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThis listing shows Armored (no FEP) protection. What other options are available?\u003cbr\u003e\u003c\/strong\u003eFor containment of glass and fill on breakage, upgrade to the FEP Encapsulated + Armored version (80x01E-A \/ 80x06E-A series).\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHow do I select the right temperature range?\u003cbr\u003e\u003c\/strong\u003eChoose a range where your target temperature falls in the middle third of the scale — this provides the most accurate readings and the longest usable column length for interpolation. Avoid using thermometers at the extreme ends of their rated range, where accuracy and resolution are reduced.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eVEE GEE Scientific manufactures these thermometers from premium borosilicate glass with permanently etched scales and individually serialized markings. Each thermometer is filled with Safety Blue organic liquid verified for consistent performance across the full rated temperature range. Nickel-plated brass armor is fitted and inspected for secure engagement and impact resistance. VEE GEE backs these thermometers with a 1-year warranty.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAs an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"VEE GEE Scientific","offers":[{"title":"Total Immersion \/ -35 to 50°C","offer_id":48075655577832,"sku":"80706-A","price":45.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -35 to 50°C","offer_id":48075655610600,"sku":"80906-A","price":45.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ -20 to 110°C","offer_id":48075655643368,"sku":"80707-A","price":45.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -20 to 110°C","offer_id":48075655676136,"sku":"80907-A","price":45.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ -20 to 150°C","offer_id":48075655708904,"sku":"80708-A","price":45.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -20 to 150°C","offer_id":48075655741672,"sku":"80908-A","price":45.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ 20 to 200°C (16in)","offer_id":48075655774440,"sku":"80905-A","price":57.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -10 to 250°C (15.4in)","offer_id":48075655807208,"sku":"80910-A","price":57.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/unnamed_cd691a96-80d6-4a17-bb28-b7cf77b5c7c3.jpg?v=1771817222"},{"product_id":"veegee-thermometer-fep-f","title":"VEE GEE Scientific FEP Encapsulated Glass Thermometer - Fahrenheit - Mercury-Free Safety Blue","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eWhen a bare glass thermometer breaks, glass fragments and chemical fill scatter across the work surface — creating an immediate safety hazard and potential sample contamination. The VEE GEE Scientific FEP Encapsulated Glass Thermometer eliminates this risk: a fluorinated ethylene propylene (FEP) sleeve surrounds the glass, and if the thermometer breaks, the FEP coating contains the glass fragments and mercury-free blue liquid fill in place, preventing injury and contamination.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe FEP layer adds chemical resistance without adding significant bulk or weight, maintaining the slim profile required for thermometer wells, water baths, and tight-clearance applications. Available in Fahrenheit (°F) scale across multiple temperature ranges in both Total and Partial Immersion configurations. Each thermometer is individually serialized for calibration traceability.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eFEP Encapsulation - Breakage Containment:\u003c\/strong\u003e Fluorinated ethylene propylene sleeve surrounds the full thermometer length — in the event of breakage, glass fragments and blue liquid fill are contained by the FEP coating, preventing contamination of samples or injury to personnel.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMercury-Free Safety Blue Fill:\u003c\/strong\u003e Organic, biodegradable blue liquid performs equivalently to mercury — no hazardous material disposal requirements, no mercury shipping restrictions, fully compliant with mercury-free laboratory policies.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIndividually Serialized:\u003c\/strong\u003e Unique serial number on every thermometer for calibration record-keeping, instrument tracking, and regulatory documentation in GLP and ISO-compliant environments.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eChemical Resistance:\u003c\/strong\u003e FEP encapsulation provides an additional chemical-resistant outer layer that protects against corrosive reagent splashes and aggressive cleaning agents that could etch bare glass.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eBorosilicate Glass with Etched Scale:\u003c\/strong\u003e Premium glass construction with permanently etched temperature graduations — scale is part of the glass, not a paper or adhesive label that can be removed by cleaning.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSafety Blue Against White Background:\u003c\/strong\u003e High-contrast blue fill against a white enamel background for clear reading in standard laboratory lighting without magnification.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTotal and Partial Immersion Options:\u003c\/strong\u003e Total Immersion thermometers for fully submerged measurement; Partial Immersion for applications where only part of the thermometer contacts the measured medium.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMultiple Temperature Ranges:\u003c\/strong\u003e Available in 4 temperature ranges in Fahrenheit (°F) scale — choose the range that best covers your application.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications by Temperature Range\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTemperature Range\u003c\/th\u003e\n\u003cth\u003eImmersion Type\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-30 to 120°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80701E (Total) \/ 80901E (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-4 to 230°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80702E (Total) \/ 80902E (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0 to 300°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80703E (Total) \/ 80903E (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e30 to 220°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e16 in (40.6 cm)\u003c\/td\u003e\n\u003ctd\u003e80704E (Total) \/ 80904E (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eVEE GEE Thermometer Protection Level Guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eLevel\u003c\/th\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003cth\u003eBreakage Containment\u003c\/th\u003e\n\u003cth\u003eImpact Protection\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP Encapsulated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP sleeve\u003c\/td\u003e\n\u003ctd\u003eYes — glass and fill contained\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNickel-plated brass armor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP + Armored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP + Brass Armor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLaboratory water bath and heating block temperature verification where liquid-in-glass accuracy and mercury-free certification are both required\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFood and beverage processing where temperature compliance monitoring requires traceable, serialized thermometers meeting mercury-free standards\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eEnvironmental monitoring, wastewater treatment, and field sampling where general-purpose Fahrenheit (°F) measurement is required with minimal calibration overhead\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eUniversity teaching labs requiring affordable, accurate thermometers with serialized traceability for student experiment documentation\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is Safety Blue fill and is it safe if the thermometer breaks?\u003cbr\u003e\u003c\/strong\u003eSafety Blue is VEE GEE's organic, biodegradable blue liquid that replaces mercury in liquid-in-glass thermometers. It is non-toxic and non-hazardous — unlike mercury, a broken Safety Blue thermometer does not require mercury spill response procedures. The liquid is safe to handle and the instrument can be disposed of in standard laboratory glass waste rather than as hazardous waste.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is the difference between Total and Partial Immersion?\u003cbr\u003e\u003c\/strong\u003eTotal Immersion thermometers are calibrated for use when the entire thermometer (bulb and liquid column) is submerged in the measured medium — this provides maximum accuracy. Partial Immersion thermometers are calibrated for use when only the lower portion (typically 3 inches) is immersed, with the upper portion in air. Choose Total for water baths and enclosed temperature measurement; Partial for applications where full immersion is not possible.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat does \"serialized\" mean for these thermometers?\u003cbr\u003e\u003c\/strong\u003eEach thermometer is individually marked with a unique serial number during manufacturing. The serial number ties the instrument to production lot records and enables calibration documentation — important for GLP compliance, ISO 17025 requirements, and any laboratory quality system requiring instrument-level traceability.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThis listing shows FEP Encapsulated (no Armor) protection. What other options are available?\u003cbr\u003e\u003c\/strong\u003eFor impact and shock protection in addition to breakage containment, upgrade to the FEP + Armored version (80x01E-A \/ 80x06E-A series).\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHow do I select the right temperature range?\u003cbr\u003e\u003c\/strong\u003eChoose a range where your target temperature falls in the middle third of the scale — this provides the most accurate readings and the longest usable column length for interpolation. Avoid using thermometers at the extreme ends of their rated range, where accuracy and resolution are reduced.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eVEE GEE Scientific manufactures these thermometers from premium borosilicate glass with permanently etched scales and individually serialized markings. Each thermometer is filled with Safety Blue organic liquid verified for consistent performance across the full rated temperature range. FEP encapsulation is applied and tested for complete glass and liquid containment integrity. VEE GEE backs these thermometers with a 1-year warranty.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAs an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"VEE GEE Scientific","offers":[{"title":"Total Immersion \/ -30 to 120°F","offer_id":48075656397032,"sku":"80701E","price":59.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -30 to 120°F","offer_id":48075656429800,"sku":"80901E","price":59.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ -4 to 230°F","offer_id":48075656462568,"sku":"80702E","price":59.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -4 to 230°F","offer_id":48075656495336,"sku":"80902E","price":59.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ 0 to 300°F","offer_id":48075656528104,"sku":"80703E","price":59.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ 0 to 300°F","offer_id":48075656560872,"sku":"80903E","price":59.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ 30 to 220°F (16in)","offer_id":48075656593640,"sku":"80704E","price":75.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ 30 to 220°F (16in)","offer_id":48075656626408,"sku":"80904E","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/unnamed_f08d3464-cac0-4fa5-98b7-808019c07f65.jpg?v=1771817224"},{"product_id":"veegee-thermometer-fep-c","title":"VEE GEE Scientific FEP Encapsulated Glass Thermometer - Celsius - Mercury-Free Safety Blue","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eWhen a bare glass thermometer breaks, glass fragments and chemical fill scatter across the work surface — creating an immediate safety hazard and potential sample contamination. The VEE GEE Scientific FEP Encapsulated Glass Thermometer eliminates this risk: a fluorinated ethylene propylene (FEP) sleeve surrounds the glass, and if the thermometer breaks, the FEP coating contains the glass fragments and mercury-free blue liquid fill in place, preventing injury and contamination.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe FEP layer adds chemical resistance without adding significant bulk or weight, maintaining the slim profile required for thermometer wells, water baths, and tight-clearance applications. Available in Celsius (°C) scale across multiple temperature ranges in both Total and Partial Immersion configurations. Each thermometer is individually serialized for calibration traceability.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eFEP Encapsulation - Breakage Containment:\u003c\/strong\u003e Fluorinated ethylene propylene sleeve surrounds the full thermometer length — in the event of breakage, glass fragments and blue liquid fill are contained by the FEP coating, preventing contamination of samples or injury to personnel.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMercury-Free Safety Blue Fill:\u003c\/strong\u003e Organic, biodegradable blue liquid performs equivalently to mercury — no hazardous material disposal requirements, no mercury shipping restrictions, fully compliant with mercury-free laboratory policies.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIndividually Serialized:\u003c\/strong\u003e Unique serial number on every thermometer for calibration record-keeping, instrument tracking, and regulatory documentation in GLP and ISO-compliant environments.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eChemical Resistance:\u003c\/strong\u003e FEP encapsulation provides an additional chemical-resistant outer layer that protects against corrosive reagent splashes and aggressive cleaning agents that could etch bare glass.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eBorosilicate Glass with Etched Scale:\u003c\/strong\u003e Premium glass construction with permanently etched temperature graduations — scale is part of the glass, not a paper or adhesive label that can be removed by cleaning.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSafety Blue Against White Background:\u003c\/strong\u003e High-contrast blue fill against a white enamel background for clear reading in standard laboratory lighting without magnification.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTotal and Partial Immersion Options:\u003c\/strong\u003e Total Immersion thermometers for fully submerged measurement; Partial Immersion for applications where only part of the thermometer contacts the measured medium.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMultiple Temperature Ranges:\u003c\/strong\u003e Available in 3 temperature ranges in Celsius (°C) scale — choose the range that best covers your application.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications by Temperature Range\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTemperature Range\u003c\/th\u003e\n\u003cth\u003eImmersion Type\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-35 to 50°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80706E (Total) \/ 80906E (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-20 to 110°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80707E (Total) \/ 80907E (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-20 to 150°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80708E (Total) \/ 80908E (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eVEE GEE Thermometer Protection Level Guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eLevel\u003c\/th\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003cth\u003eBreakage Containment\u003c\/th\u003e\n\u003cth\u003eImpact Protection\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP Encapsulated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP sleeve\u003c\/td\u003e\n\u003ctd\u003eYes — glass and fill contained\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNickel-plated brass armor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP + Armored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP + Brass Armor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLaboratory water bath and heating block temperature verification where liquid-in-glass accuracy and mercury-free certification are both required\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFood and beverage processing where temperature compliance monitoring requires traceable, serialized thermometers meeting mercury-free standards\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eEnvironmental monitoring, wastewater treatment, and field sampling where general-purpose Celsius (°C) measurement is required with minimal calibration overhead\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eUniversity teaching labs requiring affordable, accurate thermometers with serialized traceability for student experiment documentation\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is Safety Blue fill and is it safe if the thermometer breaks?\u003cbr\u003e\u003c\/strong\u003eSafety Blue is VEE GEE's organic, biodegradable blue liquid that replaces mercury in liquid-in-glass thermometers. It is non-toxic and non-hazardous — unlike mercury, a broken Safety Blue thermometer does not require mercury spill response procedures. The liquid is safe to handle and the instrument can be disposed of in standard laboratory glass waste rather than as hazardous waste.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is the difference between Total and Partial Immersion?\u003cbr\u003e\u003c\/strong\u003eTotal Immersion thermometers are calibrated for use when the entire thermometer (bulb and liquid column) is submerged in the measured medium — this provides maximum accuracy. Partial Immersion thermometers are calibrated for use when only the lower portion (typically 3 inches) is immersed, with the upper portion in air. Choose Total for water baths and enclosed temperature measurement; Partial for applications where full immersion is not possible.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat does \"serialized\" mean for these thermometers?\u003cbr\u003e\u003c\/strong\u003eEach thermometer is individually marked with a unique serial number during manufacturing. The serial number ties the instrument to production lot records and enables calibration documentation — important for GLP compliance, ISO 17025 requirements, and any laboratory quality system requiring instrument-level traceability.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThis listing shows FEP Encapsulated (no Armor) protection. What other options are available?\u003cbr\u003e\u003c\/strong\u003eFor impact and shock protection in addition to breakage containment, upgrade to the FEP + Armored version (80x01E-A \/ 80x06E-A series).\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHow do I select the right temperature range?\u003cbr\u003e\u003c\/strong\u003eChoose a range where your target temperature falls in the middle third of the scale — this provides the most accurate readings and the longest usable column length for interpolation. Avoid using thermometers at the extreme ends of their rated range, where accuracy and resolution are reduced.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eVEE GEE Scientific manufactures these thermometers from premium borosilicate glass with permanently etched scales and individually serialized markings. Each thermometer is filled with Safety Blue organic liquid verified for consistent performance across the full rated temperature range. FEP encapsulation is applied and tested for complete glass and liquid containment integrity. VEE GEE backs these thermometers with a 1-year warranty.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAs an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"VEE GEE Scientific","offers":[{"title":"Total Immersion \/ -35 to 50°C","offer_id":48075657150696,"sku":"80706E","price":59.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -35 to 50°C","offer_id":48075657183464,"sku":"80906E","price":59.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ -20 to 110°C","offer_id":48075657216232,"sku":"80707E","price":59.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -20 to 110°C","offer_id":48075657249000,"sku":"80907E","price":59.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ -20 to 150°C","offer_id":48075657281768,"sku":"80708E","price":59.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -20 to 150°C","offer_id":48075657314536,"sku":"80908E","price":59.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/unnamed_e51b3acf-5d1e-451c-8722-93d26402eb65.jpg?v=1771817226"},{"product_id":"veegee-thermometer-bare-f","title":"VEE GEE Scientific Blue Liquid Glass Thermometer - Fahrenheit - Serialized, Mercury-Free, Borosilicate","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003ePrecision liquid-in-glass thermometry without the mercury — the VEE GEE Scientific Blue Liquid Glass Thermometer delivers reliable, accurate temperature measurement across a wide range of laboratory and industrial applications using an organic, mercury-free Safety Blue fill that is biodegradable and non-toxic. Built from premium borosilicate glass with permanently etched temperature scales, these thermometers are designed for labs, universities, food and beverage processing, environmental monitoring, and wastewater treatment where accurate measurement and mercury-free certification are both required.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eEach thermometer is individually serialized for calibration traceability. Available in Fahrenheit (°F) scale across multiple temperature ranges and both Total and Partial Immersion configurations. For higher protection levels, VEE GEE also offers FEP Encapsulated, Armored, and FEP+Armored versions of these thermometers.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMercury-Free Safety Blue Fill:\u003c\/strong\u003e Organic, biodegradable blue fill liquid performs comparably to mercury across the full temperature range — no hazardous material disposal, no mercury shipping restrictions, fully compatible with mercury-free laboratory requirements.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePremium Borosilicate Glass:\u003c\/strong\u003e High-quality borosilicate glass provides thermal expansion stability, chemical resistance, and mechanical strength for reliable performance in laboratory, food processing, and industrial measurement environments.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePermanently Etched Temperature Scale:\u003c\/strong\u003e Graduations are etched directly into the glass and filled with white enamel — the scale cannot wear, smear, or peel through repeated handling and cleaning cycles.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIndividually Serialized:\u003c\/strong\u003e Unique serial number on every thermometer enables calibration record-keeping and instrument tracking for GLP, ISO, and general laboratory quality documentation.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSafety Blue Against White Background:\u003c\/strong\u003e High-contrast blue liquid column on white enamel background — clear reading in standard lab lighting conditions without magnification aids.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTotal and Partial Immersion Options:\u003c\/strong\u003e Total Immersion for highest accuracy when fully submerged; Partial Immersion for applications where only the lower portion of the thermometer contacts the measured medium.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMultiple Temperature Ranges:\u003c\/strong\u003e Available in 4 temperature ranges in Fahrenheit (°F) scale. For breakage protection, upgrade to FEP Encapsulated or Armored versions.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications by Temperature Range\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTemperature Range\u003c\/th\u003e\n\u003cth\u003eImmersion Type\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-30 to 120°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80701 (Total) \/ 80901 (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-4 to 230°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80702 (Total) \/ 80902 (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0 to 300°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80703 (Total) \/ 80903 (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20 to 500°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePartial only Immersion\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e16 in (40.6 cm)\u003c\/td\u003e\n\u003ctd\u003e— (Total) \/ 80905 (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eVEE GEE Thermometer Protection Level Guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eLevel\u003c\/th\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003cth\u003eBreakage Containment\u003c\/th\u003e\n\u003cth\u003eImpact Protection\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP Encapsulated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP sleeve\u003c\/td\u003e\n\u003ctd\u003eYes — glass and fill contained\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNickel-plated brass armor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP + Armored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP + Brass Armor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLaboratory water bath and heating block temperature verification where liquid-in-glass accuracy and mercury-free certification are both required\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFood and beverage processing where temperature compliance monitoring requires traceable, serialized thermometers meeting mercury-free standards\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eEnvironmental monitoring, wastewater treatment, and field sampling where general-purpose Fahrenheit (°F) measurement is required with minimal calibration overhead\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eUniversity teaching labs requiring affordable, accurate thermometers with serialized traceability for student experiment documentation\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is Safety Blue fill and is it safe if the thermometer breaks?\u003cbr\u003e\u003c\/strong\u003eSafety Blue is VEE GEE's organic, biodegradable blue liquid that replaces mercury in liquid-in-glass thermometers. It is non-toxic and non-hazardous — unlike mercury, a broken Safety Blue thermometer does not require mercury spill response procedures. The liquid is safe to handle and the instrument can be disposed of in standard laboratory glass waste rather than as hazardous waste.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is the difference between Total and Partial Immersion?\u003cbr\u003e\u003c\/strong\u003eTotal Immersion thermometers are calibrated for use when the entire thermometer (bulb and liquid column) is submerged in the measured medium — this provides maximum accuracy. Partial Immersion thermometers are calibrated for use when only the lower portion (typically 3 inches) is immersed, with the upper portion in air. Choose Total for water baths and enclosed temperature measurement; Partial for applications where full immersion is not possible.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat does \"serialized\" mean for these thermometers?\u003cbr\u003e\u003c\/strong\u003eEach thermometer is individually marked with a unique serial number during manufacturing. The serial number ties the instrument to production lot records and enables calibration documentation — important for GLP compliance, ISO 17025 requirements, and any laboratory quality system requiring instrument-level traceability.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThis listing shows Standard (no FEP or Armor) protection. What other options are available?\u003cbr\u003e\u003c\/strong\u003eFor breakage protection, upgrade to FEP Encapsulated (80x01E series) or Armored (80x01-A series). For maximum protection, select FEP + Armored (80x01E-A series).\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHow do I select the right temperature range?\u003cbr\u003e\u003c\/strong\u003eChoose a range where your target temperature falls in the middle third of the scale — this provides the most accurate readings and the longest usable column length for interpolation. Avoid using thermometers at the extreme ends of their rated range, where accuracy and resolution are reduced.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eVEE GEE Scientific manufactures these thermometers from premium borosilicate glass with permanently etched scales and individually serialized markings. Each thermometer is filled with Safety Blue organic liquid verified for consistent performance across the full rated temperature range. VEE GEE backs these thermometers with a 1-year warranty.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAs an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"VEE GEE Scientific","offers":[{"title":"Total Immersion \/ -30 to 120°F","offer_id":48075657806056,"sku":"80701","price":29.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -30 to 120°F","offer_id":48075657838824,"sku":"80901","price":29.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ -4 to 230°F","offer_id":48075657871592,"sku":"80702","price":29.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -4 to 230°F","offer_id":48075657904360,"sku":"80902","price":29.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ 0 to 300°F","offer_id":48075657937128,"sku":"80703","price":29.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ 0 to 300°F","offer_id":48075657969896,"sku":"80903","price":29.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ 20 to 500°F (16in)","offer_id":48075658002664,"sku":"80905","price":36.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/unnamed_88033390-3c80-470e-ba6c-78ac468d123b.jpg?v=1771817228"},{"product_id":"veegee-thermometer-bare-c","title":"VEE GEE Scientific Blue Liquid Glass Thermometer - Celsius - Serialized, Mercury-Free, Borosilicate","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003ePrecision liquid-in-glass thermometry without the mercury — the VEE GEE Scientific Blue Liquid Glass Thermometer delivers reliable, accurate temperature measurement across a wide range of laboratory and industrial applications using an organic, mercury-free Safety Blue fill that is biodegradable and non-toxic. Built from premium borosilicate glass with permanently etched temperature scales, these thermometers are designed for labs, universities, food and beverage processing, environmental monitoring, and wastewater treatment where accurate measurement and mercury-free certification are both required.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eEach thermometer is individually serialized for calibration traceability. Available in Celsius (°C) scale across multiple temperature ranges and both Total and Partial Immersion configurations. For higher protection levels, VEE GEE also offers FEP Encapsulated, Armored, and FEP+Armored versions of these thermometers.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMercury-Free Safety Blue Fill:\u003c\/strong\u003e Organic, biodegradable blue fill liquid performs comparably to mercury across the full temperature range — no hazardous material disposal, no mercury shipping restrictions, fully compatible with mercury-free laboratory requirements.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePremium Borosilicate Glass:\u003c\/strong\u003e High-quality borosilicate glass provides thermal expansion stability, chemical resistance, and mechanical strength for reliable performance in laboratory, food processing, and industrial measurement environments.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePermanently Etched Temperature Scale:\u003c\/strong\u003e Graduations are etched directly into the glass and filled with white enamel — the scale cannot wear, smear, or peel through repeated handling and cleaning cycles.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIndividually Serialized:\u003c\/strong\u003e Unique serial number on every thermometer enables calibration record-keeping and instrument tracking for GLP, ISO, and general laboratory quality documentation.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSafety Blue Against White Background:\u003c\/strong\u003e High-contrast blue liquid column on white enamel background — clear reading in standard lab lighting conditions without magnification aids.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTotal and Partial Immersion Options:\u003c\/strong\u003e Total Immersion for highest accuracy when fully submerged; Partial Immersion for applications where only the lower portion of the thermometer contacts the measured medium.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMultiple Temperature Ranges:\u003c\/strong\u003e Available in 4 temperature ranges in Celsius (°C) scale. For breakage protection, upgrade to FEP Encapsulated or Armored versions.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications by Temperature Range\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTemperature Range\u003c\/th\u003e\n\u003cth\u003eImmersion Type\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-35 to 50°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80706 (Total) \/ 80906 (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-20 to 110°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80707 (Total) \/ 80907 (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-20 to 150°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal\/Partial Immersion\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e12 in (30.5 cm)\u003c\/td\u003e\n\u003ctd\u003e80708 (Total) \/ 80908 (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-10 to 250°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePartial only Immersion\u003c\/td\u003e\n\u003ctd\u003e2°C\u003c\/td\u003e\n\u003ctd\u003e15.4 in (39 cm)\u003c\/td\u003e\n\u003ctd\u003e— (Total) \/ 80910 (Partial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eVEE GEE Thermometer Protection Level Guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eLevel\u003c\/th\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003cth\u003eBreakage Containment\u003c\/th\u003e\n\u003cth\u003eImpact Protection\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP Encapsulated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP sleeve\u003c\/td\u003e\n\u003ctd\u003eYes — glass and fill contained\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNickel-plated brass armor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFEP + Armored\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP + Brass Armor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLaboratory water bath and heating block temperature verification where liquid-in-glass accuracy and mercury-free certification are both required\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFood and beverage processing where temperature compliance monitoring requires traceable, serialized thermometers meeting mercury-free standards\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eEnvironmental monitoring, wastewater treatment, and field sampling where general-purpose Celsius (°C) measurement is required with minimal calibration overhead\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eUniversity teaching labs requiring affordable, accurate thermometers with serialized traceability for student experiment documentation\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is Safety Blue fill and is it safe if the thermometer breaks?\u003cbr\u003e\u003c\/strong\u003eSafety Blue is VEE GEE's organic, biodegradable blue liquid that replaces mercury in liquid-in-glass thermometers. It is non-toxic and non-hazardous — unlike mercury, a broken Safety Blue thermometer does not require mercury spill response procedures. The liquid is safe to handle and the instrument can be disposed of in standard laboratory glass waste rather than as hazardous waste.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is the difference between Total and Partial Immersion?\u003cbr\u003e\u003c\/strong\u003eTotal Immersion thermometers are calibrated for use when the entire thermometer (bulb and liquid column) is submerged in the measured medium — this provides maximum accuracy. Partial Immersion thermometers are calibrated for use when only the lower portion (typically 3 inches) is immersed, with the upper portion in air. Choose Total for water baths and enclosed temperature measurement; Partial for applications where full immersion is not possible.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat does \"serialized\" mean for these thermometers?\u003cbr\u003e\u003c\/strong\u003eEach thermometer is individually marked with a unique serial number during manufacturing. The serial number ties the instrument to production lot records and enables calibration documentation — important for GLP compliance, ISO 17025 requirements, and any laboratory quality system requiring instrument-level traceability.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThis listing shows Standard (no FEP or Armor) protection. What other options are available?\u003cbr\u003e\u003c\/strong\u003eFor breakage protection, upgrade to FEP Encapsulated (80x01E series) or Armored (80x01-A series). For maximum protection, select FEP + Armored (80x01E-A series).\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHow do I select the right temperature range?\u003cbr\u003e\u003c\/strong\u003eChoose a range where your target temperature falls in the middle third of the scale — this provides the most accurate readings and the longest usable column length for interpolation. Avoid using thermometers at the extreme ends of their rated range, where accuracy and resolution are reduced.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eVEE GEE Scientific manufactures these thermometers from premium borosilicate glass with permanently etched scales and individually serialized markings. Each thermometer is filled with Safety Blue organic liquid verified for consistent performance across the full rated temperature range. VEE GEE backs these thermometers with a 1-year warranty.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAs an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"VEE GEE Scientific","offers":[{"title":"Total Immersion \/ -35 to 50°C","offer_id":48075658559720,"sku":"80706","price":29.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -35 to 50°C","offer_id":48075658592488,"sku":"80906","price":29.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ -20 to 110°C","offer_id":48075658625256,"sku":"80707","price":29.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -20 to 110°C","offer_id":48075658658024,"sku":"80907","price":29.0,"currency_code":"USD","in_stock":true},{"title":"Total Immersion \/ -20 to 150°C","offer_id":48075658690792,"sku":"80708","price":29.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -20 to 150°C","offer_id":48075658723560,"sku":"80908","price":29.0,"currency_code":"USD","in_stock":true},{"title":"Partial Immersion \/ -10 to 250°C (15.4in)","offer_id":48075658756328,"sku":"80910","price":36.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/unnamed_34be4d64-23a9-4f3d-920a-61a415723815.jpg?v=1771817230"},{"product_id":"veegee-thermometer-dial-pocket","title":"VEE GEE Scientific Pocket Dial Thermometer - 1 in Face, No Battery Required","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eA digital thermometer requires a battery, a display, and electronics — all components that can fail in a pocket or drop on a production floor. The VEE GEE Scientific Pocket Dial Thermometer is mechanically operated: a bimetal coil responds to temperature and directly moves the pointer, with no power source required and no electronics to fail. Clip it to a pocket, hang it from a lanyard, or mount it on a panel — it reads temperature immediately and continuously without turning on.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe 1-inch face packs a full temperature scale in a pocket-safe format. Available in three ranges — two Celsius models covering cold storage through general lab use, and one Fahrenheit model for ambient to warm process monitoring. Resolution of 1°C or 1°F across the full scale. All three covered by a 1-year warranty.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003ePocket\/Clip Format — 1 in (25 mm) Face:\u003c\/strong\u003e\u003c\/strong\u003e Compact 1-inch face diameter with a pocket clip — designed for technicians who carry measurement tools on person. Reads while clipped to a pocket, lanyard, or equipment panel.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003eNo Battery Required:\u003c\/strong\u003e\u003c\/strong\u003e Bimetal coil responds to temperature mechanically — no batteries, no electronics to fail. Always operational, even after storage without power.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e\u003c\/strong\u003e Designed for industrial and field environments where the thermometer may be dropped, splashed, or exposed to rough handling.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003e1°C \/ 1°F Resolution:\u003c\/strong\u003e\u003c\/strong\u003e Fine graduation for accurate reading within the pocket thermometer format.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003eAvailable in C and F Scales:\u003c\/strong\u003e\u003c\/strong\u003e Three models — two Celsius (81070: -40 to 70°C; 81110: -10 to 110°C) and one Fahrenheit (81125: 25 to 125°F) — cover the most common general-purpose and food safety temperature ranges.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications by Model\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eFace Diameter\u003c\/th\u003e\n\u003cth\u003eScale\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e81070\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 70°C\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e1 in (25 mm)\u003c\/td\u003e\n\u003ctd\u003eCelsius\u003c\/td\u003e\n\u003ctd\u003eCold storage, freezer, general\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e81110\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 110°C\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e1 in (25 mm)\u003c\/td\u003e\n\u003ctd\u003eCelsius\u003c\/td\u003e\n\u003ctd\u003eGeneral lab, food safety, process\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e81125\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 to 125°F\u003c\/td\u003e\n\u003ctd\u003e1°F\u003c\/td\u003e\n\u003ctd\u003e1 in (25 mm)\u003c\/td\u003e\n\u003ctd\u003eFahrenheit\u003c\/td\u003e\n\u003ctd\u003eAmbient and warm process monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFood service and food safety — pocket temperature checks of food holding, chilled storage, and hot-hold equipment where fast spot-checking is required without dedicated instruments\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLaboratory and process monitoring where a battery-free backup thermometer is needed in case of digital instrument failure\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eCold chain and refrigeration monitoring in field environments where battery reliability is a concern\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eQuality control personnel and inspectors who need a personal thermometer that is always available and ready without battery checks\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHow accurate are these pocket dial thermometers?\u003cbr\u003e\u003c\/strong\u003e81125 is rated ±1°F; 81070 and 81110 accuracy is ±1°C at mid-scale under standard conditions. Dial thermometers have inherent mechanical tolerance — for calibration-traceable high-accuracy measurements, use a digital instrument. These are suited for general monitoring, spot checks, and safety verification where ±1°C\/°F accuracy is sufficient.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eCan these be calibrated or adjusted?\u003cbr\u003e\u003c\/strong\u003eMost dial thermometers have a calibration nut at the back of the face that allows zero adjustment. Immerse the stem in an ice water bath (0°C\/32°F) and adjust the pointer to match the reference if needed. For more complex re-ranging, contact VEE GEE Scientific.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is the stem length on these pocket thermometers?\u003cbr\u003e\u003c\/strong\u003ePocket dial thermometers have a short stem — typically 1–2 inches — appropriate for surface probing and shallow liquid measurements. They are not suitable for deep immersion applications where a full-length stem thermometer is required.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eVEE GEE Scientific pocket dial dial thermometers are manufactured from bimetal coil technology with factory-set accuracy and permanently marked faces. Each unit is inspected for graduation clarity and dial pointer alignment before shipment. Covered by a 1-year warranty against manufacturing defects.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAs an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"VEE GEE Scientific","offers":[{"title":"-40 to 70°C (Celsius)","offer_id":48078562066664,"sku":"81070","price":7.0,"currency_code":"USD","in_stock":true},{"title":"-10 to 110°C (Celsius)","offer_id":48078562099432,"sku":"81110","price":7.0,"currency_code":"USD","in_stock":true},{"title":"25 to 125°F (Fahrenheit)","offer_id":48078562132200,"sku":"81125","price":7.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/unnamed_2756081d-1af7-4512-be8e-eced23a9b838.jpg?v=1771854459"},{"product_id":"veegee-thermometer-dial-large","title":"VEE GEE Scientific Dial Thermometer 3 in Face - 6 or 12 in Stem, Bimetal","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003ePanel meters and process thermometers need to be readable from a distance — a 1.75-inch face requires standing close and looking carefully, which is impractical for monitoring a tank, walk-in cooler, or processing vessel from an operating position. The VEE GEE Scientific 82160 Dial Thermometer has a 3-inch (76 mm) face that is readable at a glance from several feet away — making it appropriate for panel mounting, tank installation, and equipment monitoring where a large, immediately readable display is the priority.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAvailable in 6 in (82160-6) and 12 in (82160-12) stem lengths, both covering the -40 to 71°C \/ -40 to 160°F range in both Celsius and Fahrenheit scales simultaneously. Battery-free bimetal operation. The 6-inch stem suits surface-mount or shallow installations; the 12-inch stem reaches deep into tanks, wells, and process vessels.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003e3 in (76 mm) Face — High Visibility from a Distance:\u003c\/strong\u003e\u003c\/strong\u003e Large 3-inch dial is readable from several feet away — ideal for monitoring tanks, baths, ovens, and process equipment where the thermometer is mounted and read remotely.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003e6 or 12 in Stem Options:\u003c\/strong\u003e\u003c\/strong\u003e 82160-6 has a 6-inch stem for surface-mount and shallow well applications; 82160-12 has a 12-inch stem for deep well and tank insertion. Same face, same range, different installation depth.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003e-40 to 71°C \/ -40 to 160°F Range:\u003c\/strong\u003e\u003c\/strong\u003e Covers the most common refrigeration, cold storage, and moderate process temperature monitoring range in a single instrument.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003eNo Battery Required:\u003c\/strong\u003e\u003c\/strong\u003e Bimetal coil — always-on, no power required, suitable for continuous monitoring without battery replacement.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003e2°F \/ 1°C Resolution:\u003c\/strong\u003e\u003c\/strong\u003e Standard resolution for general process and food safety monitoring applications where ±1°C accuracy is sufficient.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications by Model\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eFace Diameter\u003c\/th\u003e\n\u003cth\u003eScale\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e82160-6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 71°C \/ -40 to 160°F\u003c\/td\u003e\n\u003ctd\u003e2°F \/ 1°C\u003c\/td\u003e\n\u003ctd\u003e3 in (76 mm)\u003c\/td\u003e\n\u003ctd\u003eC and F\u003c\/td\u003e\n\u003ctd\u003e6 in stem — shallow installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e82160-12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 71°C \/ -40 to 160°F\u003c\/td\u003e\n\u003ctd\u003e2°F \/ 1°C\u003c\/td\u003e\n\u003ctd\u003e3 in (76 mm)\u003c\/td\u003e\n\u003ctd\u003eC and F\u003c\/td\u003e\n\u003ctd\u003e12 in stem — deep well\/tank installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eWalk-in cooler and refrigerated display case temperature monitoring — panel-mount with 3 in face readable without opening the door or approaching the equipment\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eWater bath and tank temperature display where a large, continuously visible reading is required without digital instrument investment\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eHVAC duct temperature monitoring with the 12-inch stem (82160-12) for insertion into supply or return air ducts of any standard size\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eIndustrial process vessels and tank thermowells where the thermometer face is mounted externally and must be readable from an operator workstation\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhich stem length should I choose — 6 in or 12 in?\u003cbr\u003e\u003c\/strong\u003eChoose 82160-6 (6 in stem) for surface probe applications, shallow wells, or installations where the probe needs to penetrate only a few inches into the medium. Choose 82160-12 (12 in stem) for deep tank installations, duct measurement, and thermowell installations where the stem must reach the measurement zone inside a vessel or duct.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eDo both models read both Celsius and Fahrenheit simultaneously?\u003cbr\u003e\u003c\/strong\u003eYes — both 82160-6 and 82160-12 have dual C and F scales on the same 3-inch dial face. Both scales are permanently engraved and read at the same time, eliminating the need to convert between temperature systems.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is the accuracy of the 82160 series?\u003cbr\u003e\u003c\/strong\u003eBimetal dial thermometers of this size typically achieve ±2°F \/ ±1°C accuracy at mid-scale under stable conditions. For regulatory compliance or calibration-traceable measurement, verify accuracy with a reference thermometer and document the offset. Contact VEE GEE Scientific for detailed accuracy specifications.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eVEE GEE Scientific large 3 in dial thermometers are manufactured from bimetal coil technology with factory-set accuracy and permanently marked faces. Each unit is inspected for graduation clarity and dial pointer alignment before shipment. Covered by a 1-year warranty against manufacturing defects.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAs an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"VEE GEE Scientific","offers":[{"title":"-40 to 71°C \/ -40 to 160°F - 6 in Stem","offer_id":48078562361576,"sku":"82160-6","price":18.49,"currency_code":"USD","in_stock":true},{"title":"-40 to 71°C \/ -40 to 160°F - 12 in Stem","offer_id":48078562394344,"sku":"82160-12","price":24.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/unnamed_3411ec5d-df82-42d1-bfb9-231b701483b2.jpg?v=1771854463"},{"product_id":"veegee-thermometer-dial-standard","title":"VEE GEE Scientific Dial Thermometer 1.75 in Face - Bimetal, No Battery Required","description":"\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLaboratory and process monitoring thermometers that balance readability and footprint: the VEE GEE Scientific 82-Series Dial Thermometers offer a 1.75-inch face that is readable without magnification but compact enough for instrument panels, equipment ports, and benchtop applications. No batteries — the bimetal coil responds directly to temperature and moves the pointer mechanically, with no electronics between the stem and the reading.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFive models span from general laboratory use (-10 to 110°C, 25 to 125°F) through food safety and process monitoring (0 to 220°F) to high-temperature applications (50 to 550°F). The 82550DG adds a glass face with dual Celsius and Fahrenheit graduation — both scales readable simultaneously on the same dial face.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003e1.75 in (44.5 mm) Face — Clear Reading Without Magnification:\u003c\/strong\u003e\u003c\/strong\u003e Larger face than pocket models — graduations are wider apart, reducing reading error at a glance without bending close or using magnification.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003eNo Battery Required:\u003c\/strong\u003e\u003c\/strong\u003e Bimetal coil thermometry — mechanically operated, no power source, no display failure.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003eWide Temperature Range Options:\u003c\/strong\u003e\u003c\/strong\u003e Five models cover from -10°C to 550°F across multiple scales — general lab, food safety, high-temperature process, and dual-scale applications.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003eDual Scale Option (82550DG):\u003c\/strong\u003e\u003c\/strong\u003e 82550DG features a glass face with both °C and °F graduation on the same dial — eliminates scale conversion errors when working between measurement systems.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\u003cstrong\u003eCompact Stem for Tight Clearances:\u003c\/strong\u003e\u003c\/strong\u003e Standard stem diameter fits standard thermometer well ports and insertion fittings common in food processing and HVAC equipment.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSpecifications by Model\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eFace Diameter\u003c\/th\u003e\n\u003cth\u003eScale\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e82110\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 to 110°C\u003c\/td\u003e\n\u003ctd\u003e1°C\u003c\/td\u003e\n\u003ctd\u003e1.75 in (44.5 mm)\u003c\/td\u003e\n\u003ctd\u003eCelsius\u003c\/td\u003e\n\u003ctd\u003eGeneral lab and process\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e82125\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 to 125°F\u003c\/td\u003e\n\u003ctd\u003e1°F\u003c\/td\u003e\n\u003ctd\u003e1.75 in (44.5 mm)\u003c\/td\u003e\n\u003ctd\u003eFahrenheit\u003c\/td\u003e\n\u003ctd\u003eAmbient to warm monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e82220\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 220°F\u003c\/td\u003e\n\u003ctd\u003e2°F\u003c\/td\u003e\n\u003ctd\u003e1.75 in (44.5 mm)\u003c\/td\u003e\n\u003ctd\u003eFahrenheit\u003c\/td\u003e\n\u003ctd\u003eFood safety, water bath, process\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e82550\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 to 550°F\u003c\/td\u003e\n\u003ctd\u003e5°F\u003c\/td\u003e\n\u003ctd\u003e1.75 in (44.5 mm)\u003c\/td\u003e\n\u003ctd\u003eFahrenheit\u003c\/td\u003e\n\u003ctd\u003eHigh-temperature process, oven, steam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e82550DG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10–290°C \/ 50–550°F\u003c\/td\u003e\n\u003ctd\u003e5°F \/ 5°C\u003c\/td\u003e\n\u003ctd\u003e2 in (51 mm)\u003c\/td\u003e\n\u003ctd\u003eDual (C+F)\u003c\/td\u003e\n\u003ctd\u003eGlass face, dual scale high-temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eLaboratory Applications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eLaboratory incubators and ovens — panel-mount temperature monitoring where a continuous reading without power is preferred for reliability\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFood service equipment — fryer, steam table, warming oven, and refrigeration unit temperature monitoring for food safety compliance\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eHVAC and building environmental monitoring — duct temperature and return air measurement where battery-free instruments simplify maintenance\u003c\/p\u003e\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eChemical process vessels — general temperature monitoring at inlets, outlets, and reaction zones where a simple, readable instrument is appropriate\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWhat is the difference between 82550 and 82550DG?\u003cbr\u003e\u003c\/strong\u003e82550 has a standard 1.75 in face with a single Fahrenheit scale (50–550°F). 82550DG has a slightly larger 2 in glass face with dual graduation — both Celsius (10–290°C) and Fahrenheit (50–550°F) on the same dial. The glass face on 82550DG provides better scale clarity at high temperatures. Choose 82550DG if you work between °C and °F systems, or if glass face clarity is preferred.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHow long is the stem on these thermometers?\u003cbr\u003e\u003c\/strong\u003eThe stem length for 82-series dial thermometers is typically 2–4 inches depending on model — shorter than the large 82160 series. Check the product data sheet or contact us for specific stem length per model number.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eAre 82220 and 82550 suitable for oven temperature monitoring?\u003cbr\u003e\u003c\/strong\u003e82220 (0–220°F) covers the normal baking range for most food ovens. 82550 (50–550°F) extends to commercial oven and industrial kiln temperatures. Install the stem in an appropriate thermometer port or thermowell — do not expose the dial face to direct heat above its rated maximum.\u003c\/p\u003e\n\u003ch2 class=\"mb-2 mt-4 font-display font-semimedium text-base first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eQuality Assurance\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eVEE GEE Scientific standard 1.75 in dial thermometers are manufactured from bimetal coil technology with factory-set accuracy and permanently marked faces. Each unit is inspected for graduation clarity and dial pointer alignment before shipment. Covered by a 1-year warranty against manufacturing defects.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAs an authorized dealer, we ship directly from USA inventory.\u003c\/p\u003e","brand":"VEE GEE Scientific","offers":[{"title":"'-10 to 110°C (Celsius)","offer_id":48563141411048,"sku":"82110","price":11.0,"currency_code":"USD","in_stock":true},{"title":"25 to 125°F (Fahrenheit)","offer_id":48563141443816,"sku":"82125","price":11.0,"currency_code":"USD","in_stock":true},{"title":"0 to 220°F (Fahrenheit)","offer_id":48563141476584,"sku":"82220","price":11.0,"currency_code":"USD","in_stock":true},{"title":"50 to 550°F (Fahrenheit)","offer_id":48563141509352,"sku":"82550","price":11.0,"currency_code":"USD","in_stock":true},{"title":"10–290°C \/ 50–550°F Dual Scale","offer_id":48563141542120,"sku":"82550DG","price":13.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/VEE-GEE-Scientific-Products-DIAL-THERMOMETERS-175-2-DIAMETER-_1637__68479.jpg?v=1778877587"}],"url":"https:\/\/labsupplies.com\/collections\/heathrow-thermometers.oembed","provider":"LabSupplies.com","version":"1.0","type":"link"}