{"title":"AirClean Systems","description":"\u003cp\u003eAirClean Systems, of Creedmoor, North Carolina, has built ductless enclosures and laminar flow workstations since 1992. Every AC600 Series unit is a seamless polypropylene body with a clear polycarbonate shell, an electrostatic pre-filter ahead of a HEPA filter, and the UVTect® microprocessor controller that monitors the filter bed in real time and locks out the wrong replacement filter. Nothing is ducted: each workstation plugs into a standard 110 V or 220 V outlet and ships fully assembled, ISO 5 tested, to UL 61010-1 and CSA C22.2 No. 61010-1.\u003c\/p\u003e\u003ch2\u003eWhat we list, by AirClean model number\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFamily\u003c\/th\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003cth\u003eWidths\u003c\/th\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/iso-5-vertical-laminar-flow-workstation\"\u003eAC600 vertical laminar flow workstation\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAC624LF · AC632LFC · AC632TLFC · AC648LFC · AC648TLFC\u003c\/td\u003e\n\u003ctd\u003e24, 32, 48 in; standard or tall\u003c\/td\u003e\n\u003ctd\u003eISO 5 work zone for media prep, plating, non-hazardous cultures, non-hazardous sterile compounding, sample prep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/pcr-workstation\"\u003eAC600 PCR workstation, HEPA + UV\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAC624LFUV · AC632LFUVC · AC648LFUVC\u003c\/td\u003e\n\u003ctd\u003e24, 32, 48 in\u003c\/td\u003e\n\u003ctd\u003eDNA\/RNA set-up; UV irradiation of surface and tools between runs on a 1–59 min timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/airclean-ac600-mobile-cart\"\u003eAC600 mobile cart\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ematched to each width\u003c\/td\u003e\n\u003ctd\u003e24, 32, 48 in\u003c\/td\u003e\n\u003ctd\u003eLocking casters; moves the workstation between benches and rooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eHorizontal laminar flow clean benches (AC4000HLF 48 in, AC5000HLF 60 in, AC6000HLF 72 in, AC8000HLF 96 in — dual-wall polypropylene, horizontal HEPA airflow, standard, solid-wall and UV versions) and AC600 ductless chemical fume hoods, replacement HEPA and pre-filters are part of the AirClean line; email \u003ca href=\"mailto:support@labsupplies.com\"\u003esupport@labsupplies.com\u003c\/a\u003e with the model number for those until they are listed here.\u003c\/p\u003e\u003ch2\u003eChoosing between them\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eIf your work is\u003c\/th\u003e\n\u003cth\u003eChoose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile media, plates, non-hazardous cultures, non-hazardous compounding\u003c\/td\u003e\n\u003ctd\u003eAC600 vertical laminar flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCR or any amplification where carry-over between runs is the risk\u003c\/td\u003e\n\u003ctd\u003eAC600 PCR workstation (adds UV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall items placed in a line upstream of each other; IV prep with vials and syringes\u003c\/td\u003e\n\u003ctd\u003eHorizontal clean bench (AC4000HLF–AC8000HLF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnything hazardous to the operator — pathogens, human cell lines, cytotoxic drugs\u003c\/td\u003e\n\u003ctd\u003eA Class II biological safety cabinet, not a laminar flow hood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolatile or toxic chemicals\u003c\/td\u003e\n\u003ctd\u003eA ductless or ducted fume hood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eSizing\u003c\/h2\u003e\u003cp\u003e24 in suits one operator with small items; 32 in is the general-purpose bench; 48 in gives one operator a full range of motion or room for a small instrument. Tall versions add 9–11 in of internal height for racks, tall vessels and small instruments. Internal dimensions for every model are on each product page.\u003c\/p\u003e\u003ch2\u003eOrdering\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEvery unit is listed by its AirClean model number and our SKU; order by either.\u003c\/li\u003e\n\u003cli\u003eShips fully assembled by freight; the freight rate is shown at checkout.\u003c\/li\u003e\n\u003cli\u003eReplacement HEPA filters and pre-filters: email the model number and we will quote the matching part.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eQuestions\u003c\/h2\u003e\u003ch3\u003eDoes an AC600 workstation need ductwork or installation?\u003c\/h3\u003e\u003cp\u003eNo. It recirculates HEPA-filtered air to the room, plugs into a standard 110 V or 220 V outlet and arrives fully assembled.\u003c\/p\u003e\u003ch3\u003eWhat does the UVTect controller do?\u003c\/h3\u003e\u003cp\u003eIt monitors the installed filter bed in real time, warns of insufficient airflow, and locks out incorrect replacement filters so the workstation cannot run with the wrong filter fitted.\u003c\/p\u003e\u003ch3\u003eIs a laminar flow workstation safe for pathogens or human cell lines?\u003c\/h3\u003e\u003cp\u003eNo. Laminar flow directs filtered air toward the operator; it protects the work, not the person. Hazardous biological work needs a Class II biological safety cabinet.\u003c\/p\u003e\u003ch3\u003eVertical or horizontal?\u003c\/h3\u003e\u003cp\u003eVertical flow comes down from the top of the chamber and suits larger items and powders; horizontal flow comes from the back wall toward the operator and suits small items arranged upstream of each other. The AC600 units listed here are vertical flow; the AC4000HLF–AC8000HLF benches are horizontal.\u003c\/p\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Does an AC600 workstation need ductwork or installation?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. It recirculates HEPA-filtered air to the room, plugs into a standard 110 V or 220 V outlet and arrives fully assembled.\"}},{\"@type\":\"Question\",\"name\":\"What does the UVTect controller do?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It monitors the installed filter bed in real time, warns of insufficient airflow, and locks out incorrect replacement filters so the workstation cannot run with the wrong filter fitted.\"}},{\"@type\":\"Question\",\"name\":\"Is a laminar flow workstation safe for pathogens or human cell lines?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. Laminar flow directs filtered air toward the operator; it protects the work, not the person. Hazardous biological work needs a Class II biological safety cabinet.\"}},{\"@type\":\"Question\",\"name\":\"Vertical or horizontal?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Vertical flow comes down from the top of the chamber and suits larger items and powders; horizontal flow comes from the back wall toward the operator and suits small items arranged upstream of each other. The AC600 units listed here are vertical flow; the AC4000HLF–AC8000HLF benches are horizontal.\"}}]}\u003c\/script\u003e","products":[{"product_id":"pcr-workstation","title":"PCR Workstation Sterile PCR Hood with HEPA and UV","description":"\u003cp\u003eThe AirClean Systems AC600 Series PCR workstation combines ISO 5 HEPA-filtered vertical laminar airflow with UV irradiation of the work surface and tools between amplifications, so airborne contaminants stay away from samples and carry-over between runs is cut. Room air passes through an electrostatic pre-filter and a HEPA filter, flows down through the chamber and recirculates to the room — no ductwork, no installation. It plugs into a standard 110 V or 220 V outlet and ships fully assembled.\u003c\/p\u003e\u003ch2\u003eModels\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth\u003eAirClean model\u003c\/th\u003e\n\u003cth\u003eExternal W × D × H\u003c\/th\u003e\n\u003cth\u003eInternal W × D × H\u003c\/th\u003e\n\u003cth\u003eLabSupplies SKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 in\u003c\/td\u003e\n\u003ctd\u003eAC624LFUV\u003c\/td\u003e\n\u003ctd\u003e24 × 24 × 30 in\u003c\/td\u003e\n\u003ctd\u003e23 × 23 × 18 in\u003c\/td\u003e\n\u003ctd\u003e63100-24in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e32 in\u003c\/td\u003e\n\u003ctd\u003eAC632LFUVC\u003c\/td\u003e\n\u003ctd\u003e32 × 24 × 30 in\u003c\/td\u003e\n\u003ctd\u003e31 × 23 × 20 in\u003c\/td\u003e\n\u003ctd\u003e63100-32in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e48 in\u003c\/td\u003e\n\u003ctd\u003eAC648LFUVC\u003c\/td\u003e\n\u003ctd\u003e48 × 24 × 30 in\u003c\/td\u003e\n\u003ctd\u003e47 × 23 × 21 in\u003c\/td\u003e\n\u003ctd\u003e63100-48in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile cart, 24 in\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003efits AC624LFUV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e63100-24cart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile cart, 32 in\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003efits AC632LFUVC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e63100-32cart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile cart, 48 in\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003efits AC648LFUVC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e63100-48cart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eHow the UV cycle works\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDigital UV light timer, 1 to 59 minutes, for decontamination between runs\u003c\/li\u003e\n\u003cli\u003eSash safety switch turns the UV lamp off and starts the blower when the sash is raised; the overlapping polycarbonate sash blocks UV exposure while the lamp is on\u003c\/li\u003e\n\u003cli\u003eAutomatic sash switch turns the blowers off when the sash is closed and holds an air barrier\u003c\/li\u003e\n\u003cli\u003ePolycarbonate and polypropylene construction reflects UV energy back into the chamber; seamless design with no joints or gaps\u003c\/li\u003e\n\u003cli\u003eUV shelf with built-in pipettor holder; UV and LED lighting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eAirflow and controls\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eISO 5 vertical laminar flow, HEPA filtration with electrostatic pre-filter\u003c\/li\u003e\n\u003cli\u003eUVTect® microprocessor controller with real-time monitoring of the filter bed and filter safety lockout\u003c\/li\u003e\n\u003cli\u003eLow-airflow alarm, visual and audible; lab event timer\u003c\/li\u003e\n\u003cli\u003eQuiet: under 49 dBA\u003c\/li\u003e\n\u003cli\u003eFilter and electronics above the workspace; access port for electrical cords\u003c\/li\u003e\n\u003cli\u003eISO 5 tested; tested to UL 61010-1, CSA C22.2 No. 61010-1 and EN 61326-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cp\u003eULPA filter and hard-surface disinfectant — ask us for a quote with your model number. For a clean workstation without UV, see the \u003ca href=\"\/products\/iso-5-vertical-laminar-flow-workstation\"\u003eAC600 vertical laminar flow workstation\u003c\/a\u003e. All models: \u003ca href=\"\/collections\/laminar-flow-hoods\"\u003eLaminar Flow Hoods\u003c\/a\u003e.\u003c\/p\u003e","brand":"AirClean Systems","offers":[{"title":"24cart","offer_id":46569851715816,"sku":"63100-24cart","price":869.0,"currency_code":"USD","in_stock":true},{"title":"24in","offer_id":46569851748584,"sku":"63100-24in","price":3099.0,"currency_code":"USD","in_stock":true},{"title":"32cart","offer_id":46569851781352,"sku":"63100-32cart","price":919.0,"currency_code":"USD","in_stock":true},{"title":"32in","offer_id":46569851814120,"sku":"63100-32in","price":3419.0,"currency_code":"USD","in_stock":true},{"title":"48cart","offer_id":46569851846888,"sku":"63100-48cart","price":1049.0,"currency_code":"USD","in_stock":true},{"title":"48in","offer_id":46569851879656,"sku":"63100-48in","price":4469.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/my-pcr-prep-station-lab-supplies_ba955675-a957-447d-bf66-51439f45a842.jpg?v=1760666623"},{"product_id":"iso-5-vertical-laminar-flow-workstation","title":"AirClean Systems Vertical Laminar Flow Workstation - AC600 Series","description":"\u003cp\u003eThe AirClean Systems AC600 Series is a vertical laminar flow workstation for non-hazardous work that needs a clean surface: media preparation, plating, non-hazardous sterile compounding, sample preparation and electronics assembly. Room air is drawn through an electrostatic pre-filter, pushed down through a HEPA filter and delivered as ISO 5 vertical laminar flow across the whole chamber and sash opening; the air recirculates to the room, so nothing is ducted. It plugs into a standard 110 V or 220 V outlet and ships fully assembled.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat it is not.\u003c\/strong\u003e A laminar flow hood directs filtered air toward the operator — it protects the work, not the person. Pathogens, human cell lines, cytotoxic drugs or volatile chemicals call for a biological safety cabinet or a fume hood. \u003ca href=\"\/blogs\/guides\/laminar-flow-hood-guide\"\u003eWhen you need a laminar flow hood, and when you don't.\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eModels\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth\u003eAirClean model\u003c\/th\u003e\n\u003cth\u003eExternal W × D × H\u003c\/th\u003e\n\u003cth\u003eInternal W × D × H\u003c\/th\u003e\n\u003cth\u003eLabSupplies SKU\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 in\u003c\/td\u003e\n\u003ctd\u003eAC624LF\u003c\/td\u003e\n\u003ctd\u003e24 × 24 × 30 in\u003c\/td\u003e\n\u003ctd\u003e23 × 23 × 18 in\u003c\/td\u003e\n\u003ctd\u003e63101-24in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e32 in\u003c\/td\u003e\n\u003ctd\u003eAC632LFC\u003c\/td\u003e\n\u003ctd\u003e32 × 24 × 30 in\u003c\/td\u003e\n\u003ctd\u003e31 × 23 × 18 in\u003c\/td\u003e\n\u003ctd\u003e63101-32in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e32 in Tall\u003c\/td\u003e\n\u003ctd\u003eAC632TLFC\u003c\/td\u003e\n\u003ctd\u003e32 × 24 × 39 in\u003c\/td\u003e\n\u003ctd\u003e31 × 23 × 27 in\u003c\/td\u003e\n\u003ctd\u003e63101-32inT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e48 in\u003c\/td\u003e\n\u003ctd\u003eAC648LFC\u003c\/td\u003e\n\u003ctd\u003e48 × 24 × 32 in\u003c\/td\u003e\n\u003ctd\u003e47 × 23 × 18 in\u003c\/td\u003e\n\u003ctd\u003e63101-48in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e48 in Tall\u003c\/td\u003e\n\u003ctd\u003eAC648TLFC\u003c\/td\u003e\n\u003ctd\u003e48 × 24 × 40 in\u003c\/td\u003e\n\u003ctd\u003e47 × 23 × 29 in\u003c\/td\u003e\n\u003ctd\u003e63101-48inT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eChoose the tall version when tall vessels, racks or small instruments have to sit inside the chamber.\u003c\/p\u003e\u003ch2\u003eConstruction and controls\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePolypropylene body — chemically resistant, will not rust\u003c\/li\u003e\n\u003cli\u003eClear polycarbonate shell for 360° visibility\u003c\/li\u003e\n\u003cli\u003eElectrostatic pre-filtration ahead of the HEPA filter\u003c\/li\u003e\n\u003cli\u003eUVTect® microprocessor controller with real-time monitoring of the installed filter bed and a filter safety lockout so only the correct replacement filter can be fitted\u003c\/li\u003e\n\u003cli\u003eLab event timer and integral fluorescent lighting\u003c\/li\u003e\n\u003cli\u003eFilter and electronics mounted above the workspace, away from spills\u003c\/li\u003e\n\u003cli\u003eISO 5 tested; tested to UL 61010-1, CSA C22.2 No. 61010-1 and EN 61326-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOptions\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/airclean-ac600-mobile-cart\"\u003eAC600 mobile cart with locking casters\u003c\/a\u003e — matched to each width\u003c\/li\u003e\n\u003cli\u003eULPA filter, IV bar, electrical access port, polypropylene laboratory sinks — ask us for a quote with your model number\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated\u003c\/h2\u003e\u003cp\u003eFor DNA\/RNA work that needs UV decontamination between runs, see the \u003ca href=\"\/products\/pcr-workstation\"\u003eAC600 Series PCR workstation\u003c\/a\u003e. All models: \u003ca href=\"\/collections\/laminar-flow-hoods\"\u003eLaminar Flow Hoods\u003c\/a\u003e.\u003c\/p\u003e","brand":"AirClean Systems","offers":[{"title":"24 in","offer_id":46569851945192,"sku":"63101-24in","price":2889.0,"currency_code":"USD","in_stock":true},{"title":"32 in","offer_id":46569852010728,"sku":"63101-32in","price":3209.0,"currency_code":"USD","in_stock":true},{"title":"32 in Tall","offer_id":46569852043496,"sku":"63101-32inT","price":3579.0,"currency_code":"USD","in_stock":true},{"title":"48 in","offer_id":46569852109032,"sku":"63101-48in","price":4209.0,"currency_code":"USD","in_stock":true},{"title":"48 in Tall","offer_id":46569852141800,"sku":"63101-48inT","price":4729.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0694\/5361\/1240\/files\/63101_Home.jpg?v=1756432391"},{"product_id":"airclean-ac600-mobile-cart","title":"AirClean Systems AC600 Mobile Cart with Locking Casters — for Vertical Laminar Flow Workstations","description":"\u003cp\u003eThe mobile cart is a factory option for the \u003cstrong\u003eAirClean® Systems AC600 Series Vertical Laminar Flow Workstation\u003c\/strong\u003e. It turns a benchtop workstation into a mobile clean zone that can be moved between rooms, and it is sized to the workstation it supports — order the cart width that matches your hood.\u003c\/p\u003e\n\u003ch3\u003eWhat this is\u003c\/h3\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003ecart only\u003c\/strong\u003e. It does not include the laminar flow workstation. If you are buying both, order the workstation in the width you need and the matching cart alongside it.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCasters:\u003c\/strong\u003e locking, for a stable work surface once positioned\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidths:\u003c\/strong\u003e 24 in, 32 in and 48 in, matched to the AC600 workstation widths\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e AC600 Series Vertical Laminar Flow Workstations, standard and tall versions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: a vertical laminar flow workstation provides positive-pressure ISO 5 air to protect the sample. It is not a fume hood and does not protect the operator from chemical vapour. For hazardous chemistry, specify a ducted or ductless fume hood instead.\u003c\/em\u003e\u003c\/p\u003e","brand":"AirClean Systems","offers":[{"title":"24 in","offer_id":49028597776616,"sku":"63101-24cart","price":869.0,"currency_code":"USD","in_stock":true},{"title":"32 in","offer_id":49028597809384,"sku":"63101-32cart","price":919.0,"currency_code":"USD","in_stock":true},{"title":"48 in","offer_id":49028597842152,"sku":"63101-48cart","price":1049.0,"currency_code":"USD","in_stock":true}]}],"url":"https:\/\/labsupplies.com\/collections\/airclean-systems.oembed","provider":"LabSupplies.com","version":"1.0","type":"link"}